Contents Components and Features ....................2 Key Function ........................ 2 Installation and use of scale ....................2 Check carton contents ..................2 Positioning of the scale ..................2 Power supply of the scale ................. 3 Power immediate operation ................3 Power Charge Operation (only for models with rechargeable batteries): .....
Installation and use of scale Your ADE compact scale KWE in stainless steel housing is a quality product, which is designed for a lot of different weighing performances for controlling, where approval is not necessary. The scale has both-sided displays.
Place the metal weighing tray on the platform. Connect the mains adapter to the scale. Power supply of the scale Power supply is by mains with directly connected power plug (230V) or with rechargeable batteries (only for models with rechargeable batteries). The battery pack is already installed in the base of the scale.
Switch on Press [ON]. The whole display illuminates with a serial of steps and ends with the screen display „0“. After the [ZERO] indicator is lighting, the scale is ready for weighing. 2.6.1. Switch-off Scale can be turned off forcibly by pressing [OFF]. 2.6.2.
2.10 Unit operation When scale is on, press [TARE] for more than 3 seconds to change the weight unit between g, kg and lbs. Requirement is a stable weight. Selected unit will be stored, when scale is switched off. 2.11 Check weighing – Minimum and maximum values with acoustical alarm For setting minimum and maximum values, scale has to be empty.
2.12 Counting Function Switch on the scale and put on the reference number of pieces. This function can be activated only with loaded platform! Press both [SET] and [ON] keys together for 3 seconds. Display shows “pcs_y”. Press [TARE] to deactivate the counting function. Display shows “pcs_n”. To confirm your choice press [ON].
Adjustment display precision Please start as described in the beginning of this chapter to enter this menu and „PrE“ is shown in the display. Now you can change between four given graduations as shown below by pressing [TARE]. Capacity: 15kg Graduation Adjustment 0: Graduation Adjustment 1: 0.5g...
Power Saving Mode / Standby (only for models with rechargeable batteries) Please start as described in the beginning of chapter 3 to enter this menu and „SAU“ is shown in the display. By pressing [TARE] the Standby function can be enabled or disabled. Default is “SAU_2”. Adjustment 0: Standby disabled.
Printer setting Please start as described in the beginning of chapter 3 to enter this menu and „Prt_“ is shown in the display. Setting has to be “Prt_0”, because scale has no interface for connecting PC or printer. Display Symbols SP –...
Cleaning and Maintenance Cleaning Before cleaning make sure the scale has been disconnected from the socket. For cleaning just use a damp cloth or common disinfection products. Do not use any aggressive cleaning fluids. Models without rechargeable battery can be cleaned under running water. Please make sure before starting cleaning, if there’s a rechargeable battery inside.
This declaration loses their validity, in case modifications on the scales are made without manufactures approval. Hamburg, January 2019 ADE Germany GmbH & Co.KG Hammer Steindamm 27 – 29, 22089 Hamburg Germany Manufacturer: ADE Germany GmbH & Co.KG Hammer Steindamm 27 –...
Technical Data Type KWE3-IP65 KWE6-IP65 KWE15-IP65 / KWE15-IP68 Capacity 3 kg 6 kg 15 kg Graduation (d) 0.1/0.2/0.5/1g 0.2/0.5/1/2g 0.5/1/2/5g Min. Weight Maximum tare 100% maximum weight Model KWE-IP65 (with rechargeable battery) KWE15-IP68 Weighing platform 220 x 180 mm 220 x 180 mm Dimensions 230 x 290 x 115 mm 230 x 290 x 115 mm...