Honeywell Chronotherm CM67 Manual
Honeywell Chronotherm CM67 Manual

Honeywell Chronotherm CM67 Manual

Advertisement

Quick Links

Installer Set-Up Mode - Settings Table
Installer Set-Up
Factory Setting
Parameters
Number /
Abbreviation
(Press + or -
key to change)
Display
Description
Optimisation
1:0P
0
Optimisation disabled
Minimum ON Time
2:0t
1
1 minute minimum ON time
AM-PM / 24hr Display
3:Cl
0
24 hr clock display
4:At
0
No accessory module
Accessory Module Type
plugged in
5:rP
1
Time / Temperature profile
RESET Time / Temperature
Program
set to factory default
Changes to 0 when one of the
time/temp profiles are changed
You must now press the PROG 2 key to enter the next section
Heat / Cool Operation
6:HC
1
Heating Operation
7:Eh
0
Applications < 3A
Electric Heat
Pump Exercise
8:PE
0
Pump Exercise Disabled
Cycle Rate
9:Cr
6
6 cycles per hour (cph) for
gas boilers, zone valves and
fan-coil
Second Temperature
10:SS
0
No sensor fitted
Sensor
Upper Temperature Limit
11:UL
30
30°C Upper Temp. Limit
Lower Temperature Limit
12:LL
5
5°C Lower Temp. Limit
Temperature Offset
13:tO
0
No offset
Pressure Offset
14:PO
0
No offset
(needed for Weatherstation
accessory only)
Proportional Band Width
15:Pb
1.5
1.5°C Proportional Band
Return all Set-Up Features
16:FS
1
All settings held are the
factory defaults. Changes to
to Factory Settings
0 when one of the parameter
values are changed
Notes
1) When the Installer Set-Up Mode is initiated, only Category 1 (
are accessible.
Category 2 (
2) Set-Up Features are accessed by pressing the PROG. 2 key.
2) Remember to always press the INFO button to confirm that you want to store your new
Installer Set-Up setting.
3) To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position.
Home Comfort & Systems
Honeywell Control Systems Ltd.
Newhouse Industrial Estate
Motherwell, ML1 5SB
Scotland
Optional Setting
Installer Set-Up
Category
(Press keys PROG 1
or 2 to select)
1 2
Display/Setting
Description
1
Optimisation enabled
1
2 to 5
2 - 2 minutes
1
3 - 3 minutes
4 - 4 minutes
5 - 5 minutes
1
12 hr AM / PM clock display
1
1, 2
1 - Auto Time Setting Module
1
2 - Weatherstation Module
0
Time / Temperature are as
1
programmed
1
To restore the factory profile
set to 1
0
Cooling Operation
2
1
Applications 3 - 8A
2
1
Pump Exercise Enabled
2
3, 9, 12
3 - 3 cph
2
9 - 9cph
12 - 12 cph
1, 2
1 - Outside Temperature
2
Sensor fitted
2 -Remote Temp. Sensor fitted
21 to 29
21°C to 29°C adjustment in
2
1°C steps
6 to 16
6°C to 16°C adjustment in 1°C
2
steps
-3 to +3
-3°C to +3°C adjustment in
2
0.1°C steps
-99 to +99
-99 mbar to +99 mbar
2
adjustment in 1 mbar steps
1.6 to 3.0
1.6°C to 3.0°C adjustment in
2
0.1°C steps
0
Settings are as modified
2
above
To restore the factory profile
1
set to 1
1) Set-Up Features
This product has been designed with your
environment in mind! Please respect this by
disposing of all packaging, used parts and
eventually the product itself in an environ-
mentally friendly manner.
honeywell
http://europe.hbc.honeywell.com
1
3
4
a
4
c
6
honeywell
Chronotherm
Installation
2
4
b
3mm
3mm
max.
max.
5
1.0-2.5mm²
42009636-005 R3

Advertisement

loading

Summary of Contents for Honeywell Chronotherm CM67

  • Page 1 Installer Set-Up setting. mentally friendly manner. 3) To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position. honeywell Home Comfort & Systems http://europe.hbc.honeywell.com Honeywell Control Systems Ltd. Newhouse Industrial Estate Motherwell, ML1 5SB Scotland 42009636-005 R3...
  • Page 2 Special Features What do I need to do if I wish Description this feature? Optimisation (Variable The Chronotherm will adjust the start time in the morning/afternoon so the Set parameter n.1 in the installer Start Time) desired temperature is reached by the start of the program period e.g. Time set-up mode to 1 7:00, Temp 21°C.