Electric operated, piston compressors

Advertisement

ELECTRIC OPERATED, PISTON COMPRESSORS
Flexzilla
designs and manufactures products for safe opera on. However, operators and maintenance persons are
responsibile for maintaining safety. All safety precau ons are included to provide a guideline for minimizing the
possibility of accidents and property damage while equipment is in opera on. Keep these instru ons for reference.
TO ACTIVATE
WARRANTY
Scan or go to
Warranty only valid by following conditions expressed in the Warranty Statement section of the Compressor Operating Manual.
Operating Instructions &
Warranty Registration
for warranty registration
1811

Advertisement

Table of Contents
loading

Summary of Contents for Flexzilla FI05V080Y1S

  • Page 1 Operating Instructions & Warranty Registration ELECTRIC OPERATED, PISTON COMPRESSORS Flexzilla designs and manufactures products for safe opera on. However, operators and maintenance persons are ™ responsibile for maintaining safety. All safety precau ons are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in opera on.
  • Page 2: Table Of Contents

    TO ACTIVATE WARRANTY Scan or go to for warranty registration Warranty only valid by following conditions expressed in the Warranty Statement section of the Compressor Operating Manual. Flexzilla Electric operated, Two Stage, 5-10 HP Piston Air Compressors MODEL FI05V080Y1S FXS07V080V1 FXS07V080V3-208...
  • Page 3: Safety Information

    A forkli may be necessary for unloading the 5. Keep a first aid kit in a convenient place. Flexzilla compressor. Use all forkli safety measures Seek medical assistance promptly in case and require a cer ed forkli operator. Refer to figure of injury.
  • Page 4: Forklift Safety

    Opera ng Instruc ons Forkli Safety Damage may result in burs ng and cause injury or property damage. 1. Make sure li operator stays aware while moving compressor. Installa on 2. Be sure load is secure and well balanced Area before moving the compressor.
  • Page 5: Piping / Tank Installation

    Flexzilla Electric Operated, Piston Compressors Piping / Tank Installa on Minimum Pipe Size For Compressed Air Lines 1. Place tank feet on 1/4 in. thick rubber pads. (Pipe size shown in. inches) Thicker padding will increase vibra on and Length Of Piping System...
  • Page 6: Electrical Safety

    Electric Code) standards, especially those concerning equipment grounding conductors. 1. Follow all NEC and local codes for electrical wiring. Allow only authorized Flexzilla service person or ce fied electrician to install electrical components. 2. Put unit on dedicated circuit and make sure no other electrical equipment is wired into it.
  • Page 7: Operation

    Flexzilla Electric Operated, Piston Compressors Breaker Breaker Power Supply Power Supply Wire connec on Wire connec on 220 V 220 V from coil to from coil to Common pressure switch Common pressure switch Power Power Power Power Power ground wire...
  • Page 8: Start Up

    Stop con nuous run feature by closing valve so com- site glass. See figure 8. pressor will start and stop according to pressure switch. Use only Flexzilla Compressor Oil. Maintenance Use of any other product will cause product damage and void Safety Steps the warranty.
  • Page 9: Belt Adjustment

    Flexzilla Electric Operated, Piston Compressors 5. Keep all body parts and any hand-held tools or other conduc ve objects away from exposed live parts of the electrical system. Pull ring on When making repairs or adjustments, stand safety valve before each use.
  • Page 10: Maintenance Schedule

    Chan ge oil Every 3 months Inspect valve assemblies Maintenance Parts MAINKIT008 Flexzilla Filter Maintenance Kit FILTER107KIT Flexzilla Silencer Filter Replacements (Contains Qty 4) OILF004 Flexzilla Syntheic Compressor Oil Troubleshoo ng Chart Problem Possible Causes Resolu ons Low air pressure 1.
  • Page 11: Warranty

    WEEMS GLOBAL. FLEXZILLA SYNTHETIC OIL MUST be used exclusively for warranty annually. Annual proof of purchase of FLEXZILLA SYNTHETIC OIL must be maintained by the original purchaser of the compressor unit. If the unit runs out of oil, this warranty is void.