Attachments Coupling - Efco DS 2400D-PU Operator's Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

Through normal use the screen can become
dirty and should be inspected weekly and
cleaned as required.
To clean:
• Allow the muffler to cool.
• Remove the muffler cover (A).
• Remove the six (6) deflector screws (B).
• Remove the deflector (C), the gasket (D)
and spark arrester (E).
• Clean and inspect the spark arrester
screen. If the spark arrester screen is
damaged, faulty or deteriorated, replace
the screen.
• Reassemble
components
order of removal and torque the screw to
40 in/lbs (4.5 Nm).
WARNING: If the spark arrester
screen is damaged, faulty or
deteriorated, replace the screen
or entire muffler assembly.
The Spark Arrester System needs a periodic
and accurate maintenance and cleaning, in
particular:
- check periodically the spark arrester
screen and substitute it when holes, bends
or deformations appear;
- check carefully if dust, debris or organic
material is in contact with parts of the Spark
Arrester System; clean it often with tools or
shop air.
If the screen needs to be replaced, please
order the whole inner part p.n. 61370017R
(E) and 58070144R (D).
WARNING: Do not operate your
power unit if the muffler is
damaged, missing or modified.
An
improperly maintained
muffler will increase the risk of
fire and hearing loss.
MAINTENANCE

ATTACHMENTS COUPLING

To ensure constant and correct operation
of the tool, every 30 hours of operation
remove the attachment (D, Fig. 4), grease
the drive shaft inside the coupling (E,
Fig. 4) and the drive shaft at the end of
the attachment (D, Fig. 4). Use high quality
molybdenum disulphide grease. Always
grease the coupling whenever you change
the attachment.
in
reversed
en
19

Advertisement

Table of Contents
loading

Table of Contents