Disassembly And Assembly Of Lower Sealing Unit - M. J. MAILLIS GROUP SIAT SK20 Operation And Maintenance Manual

Semi-automatic sealer
Table of Contents

Advertisement

Disassembly and assembly of lower sealing unit

The operation is necessary to carry out adjustment and maintenance operations.
The figure shows the points of intervention and the description shows the proce-
dures to be adopted.
1. Mark the intervention area and pre-
vent access to the devices that, if ac-
tivated, may cause unexpected haz-
ards and jeopardize the safety level.
2. Rotate main disconnector A to posi-
tion "O" (OFF) to deactivate the
power supply.
Attention
Warning
Wear the suitable personal protective
equipment (gloves) to avoid any cut-
ting hazard.
3. Use the crank handle C to lift the
head B.
This operation is necessary to assist
the operations.
4. Check whether it is necessary to re-
move adhesive tape roll.
5. Remove lower sealing unit
6. Carry out the recommended opera-
tions.
7. Insert roll and carry out the insertion
of adhesive tape.
For further details see section "Sealing unit".
8. Insert lower sealing unit into its original position.
Operation and maintenance manual