Aborting A Button Press - Adtron 610200094 Operation Manual

3.5" mirrored hard disk
Table of Contents

Advertisement

Examples:
A new I35MB is installed in the field with two 20GB capacity media for 20GB of
mirrored storage. Bank 1 requires replacement. A 10GB media is installed and
the button pressed for rebuild. Rebuild will not start and the mirror remains
broken.
A 40GB media is then inserted in Bank 1. The rebuild copies the data from the
Bank 0 20GB drive to the new drive in Bank 1. The I35MB remains a 20GB
mirrored device.
Bank 0 media is replaced with a 60GB unit. The rebuild copies the operational
20GB from Bank 1. The I35MB now has a 40GB media in the Bank 1 and a
60GB drive in Bank 0. The I35MB remains a 20GB mirrored device.
Contact Adtron Technical support for more information regarding using
different size media.

Aborting a button press

If the bank button is pressed for longer than 20 seconds, no operation is performed.