PROCEED AS FOLLOWS:
1
Power the remote control turning ignition switch ON
START CALIBRATION:
2
Take the remote control in hand and take a position on the ground, not
in the basket. In this position, press button 9 for SERVICE menu on the
remote control and look at the information that appear on the display.
3
Press button 7 (SETUP).
4
Press button 5 (PASSWORD). The screen on
the side appears on the remote control display.
5
Press buttons 5726 in order. The screen on
the side appears with "OK" on the remote
control display. If this does not happen press
button 9 (EXIT) and return to point 4 of the
procedure.
6
Press
button
button 6 (LOAD SENS). At this point the screed
on the side appears on the remote control
display.
7
With basket empty press button 1 (SET 0KG) and wait for about 5
seconds.
8
Position a load of 200 kg in the basket. Wait for about 5 seconds and
press button 2 on the remote control (SET 200KG).
9
Wait for 5 seconds, press button 9 (EXIT). Turn ignition switch OFF.
Feed the machine and control the correct adjustment of the system.
10
9
(EXIT)
and
afterwards
PASSWORD
9 ESC
PASSWORD
OK
9 ESC
LOAD SENS
.1 SET 0 KG
.2 SET 200 KG
LOAD A: 95
LOAD B: 94
9 ESC
115