Download Print this page

IDEC HG1T Manual page 4

Small teaching pendant

Advertisement

Safety Precautions
All products are manufactured under IDEC's rigorous quality con-
trol system, but users must add a backup or failsafe provision in ap-
plications where heavy damage or personal injury may be caused
in case the HG1H/HG1T should fail.
In this catalog, safety precautions are categorized in order of im-
portance to Warning and Caution:
!
Warning
signifies a hazard that could result in
personal injury or death in the case of improper
handling.
!
Caution
signifies a hazard that could result in personal
injury or physical damage in
the case of improper handling.
Warnings
!
The unit uses an LCD as a display device. The liquid inside the
LCD is harmful to the skin. If the LCD is broken and the liquid gets
on your skin or clothes, wash the liquid off using soap, and consult
a doctor immediately.
Emergency stop circuits must be configured outside the HG1H/
HG1T by using its emergency stop switch.
Connect the equipped emergency stop switch and enabling
switches to the HG1H/HG1T so that they work in the stop cat-
egory "0" or "1" in accordance with EN60204-1.
The D-sub connector provided with the HG1H/HG1T cable is not
a water or dust-proof type. If you need a water and/or dust-proof
connector, apply a waterproofing treatment to the inlet of cable
connector or replace it with a D-sub connector that is waterproof.
When using the HG1H/HG1T, make sure to securely place your
finger on the enabling switch.
Caution
!
Use of the HG1H/HG1T at high temperature and humidity, with
condensation, corrosive gas, excessive vibration, and/or shocks
may cause electric shock, fire, and/or malfunction.
Do not drop the unit when handling or during transportation.
It may cause failure and/or breakage of the unit.
Connect the unit to a power source with a suitable rating. Improp-
er connection may cause a fire.
For wiring, select a suitable wire for the applied current and volt-
age.
Fully check for safety before starting or stopping. Improper opera-
tion may cause damage to the machine and/or accidents.
Do not disassemble, modify, or alter the unit.
Dispose of the HG1H/HG1T unit as industrial waste.
Safety
Read safety precautions and operating instructions described in the instruction or operation manual and be
!
sure to use the product properly.
Precautions
HG1H/HG1T Small Teaching Pendant
Instructions
Installation environment
In consideration of the product performance and safety, avoid in-
stalling the unit in the following locations:
Where there is a high level of dust, salt air, or iron particles
Where oil or chemical splashes occur
Where direct sunlight falls on the unit
Where a corrosive gas or flammable gas exists
Where the HG1H/HG1T unit is subjected to vibration or shock
Where condensation occurs due to rapid temperature change
Where high-voltage devices or arc-generating equipment (such
as electromagnetic switches, no-fuse breakers, etc.) are located
nearby.
Operating environment
Take the following points into consideration when installing the
HG1H/HG1T on a wall.
Install the HG1H/HG1T so that it will not be exposed to heat
generated by other equipment.
If you plan not to operate the unit using your hands, mount it on a
wall or a stand. For wall mounting, use the mounting bracket on
the back of the HG1T. For the HG1H, use the optional wall mount
bracket (Type No.: HG9Z-HK1).
Do not apply direct force to the D-sub connector.
Installation of ferrite cores
When using the HG1T in environments where it is subjected to
a lot of noise, it is recommended that ferrite cores be attached
(ZCAT2436-1330: TDK Corporation, or equivalent) to either or
both ends of the cable.
Ferrite core
Flush
Silhouette
Control
Units
Display
Lights
Display
Units
Safety
Products
Terminal
Blocks
Comm.
Terminals
AS-Interface
Relays &
Timers
Sockets
Circuit
Protectors
Power
Supplies
PLCs &
SmartRelay
Operator
Interfaces
Sensors
Control
Stations
Explosion
Protection
References
1261

Advertisement

loading