Download Print this page

Advertisement

Quick Links

Multisensor user manual
HKZW-MS08
Multisensor is a universal Z-Wave device. Along with detecting motion the device measures
the temperature, humidity and luminance . It can communicate with associated Z-Wave
devices, such as Siren, Smart Switch, etc.
Multisensor can be included and operated in any Z-Wave network with other Z-Wave
certified devices from other manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters regardless of vendor to increase
reliability of the network.
Multisensor is also a security Z-Wave device and supports the Over The Air (OTA) feature for
the product's firmware upgrade.
If you want your Multisensor to be a security device that use secure/encrypted message to
communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed.
The features list:
1) Z-Wave Plus certified for wide compatibility (500 serials product).
2) Measure temperature.
3) Measure luminance
4) Measure humidity.
5) Shock sensor.
6) The battery life is up to 2 years (default settings, motion detecting 20 times per day).
7) Low battery alarm.
8) Support firmware OTA.
Ⅰ. Familiarize yourself with your Multisensor

Advertisement

loading
Need help?

Need help?

Do you have a question about the HKZW-MS08 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hank HKZW-MS08

  • Page 1 Multisensor user manual HKZW-MS08 Multisensor is a universal Z-Wave device. Along with detecting motion the device measures the temperature, humidity and luminance . It can communicate with associated Z-Wave devices, such as Siren, Smart Switch, etc. Multisensor can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.
  • Page 2 1. Multisensor Layout 2. Technical specifications Power Supply: USB DC 5V Or CR123A Batteries (2pcs CR123A,3V,1300mAh) Storage environment: -40 -70℃ Operational temperature : -10℃~50℃ Measured temperature range: -10℃~50℃ Temperature measuring accuracy: ±2℃ Measured humidity range: 20%RH-80%RH Humidity measuring accuracy: ±8%RH(25℃) Measured luminance range: 0 lux-30000 lux LUX measuring accuracy:...
  • Page 3 Radio frequency: 868.42MHz (EU) 908.42MHz (US) Range: More than 100m outdoors About 30m indoors Dimensions: 59*59*56mm <100mA Working current: <40uA Standby current: Recommended installation height: Within 8m ( installation height 2m) PIR detection range Ⅱ. Installation  (1)Power on (battery or USB) (2)Install the sensor in a desired position using screws or 3M tape (3)Insert the Multisensor in it’s holder...
  • Page 4 Ⅲ. DETECTION AREA Multisensor’s motion detection area is shown below. Actual range of the sensor can be influenced by environment conditions. Should false motion alarms be reported, check for any moving objects within the sensor’s detection area, such as trees blowing in the wind, cars passing by, windmills.
  • Page 5 Ⅳ. Inclusion to Z-Wave network The sensor can be added to the Z-Wave network by following steps: (1)Power on the device by USB or batteries. (2)Set z-Wave gateway/hub to learning mode (see Z-Wave gateway/hub Operation Manual) (3)Triple click the device's Z-Wave button (4)The LED indicator of the sensor will keep flashing quickly.
  • Page 6 V. Exclusion from Z-Wave network The sensor can be excluded from the Z-Wave network by following steps: (1)Power on the device (2)Set z-Wave gateway/hub to exclusion mode (see Z-Wave gateway/hub Operation Manual) (3)Triple click the device's Z-Wave button (4)The LED indicator of the sensor will keep flashing quickly. If the exclusion is succeeded, the LED light will be flashing slowly (enter the SmartStart function).
  • Page 7 Ⅷ. WAKE UP COMMAND CLASS If the product is within the network, press and hold Z-Wave button for more than 3 seconds,it will broadcast Wake Up Notification when release the button, it will report that the product is waked up. Using Wake up interval set command to set the automatic wake up time.
  • Page 8 13 (0x0D) (1) Wait time for clearing the PIR triggered (default 30 seconds) If there is no trigger during this time, it will send Notification (Notification Type is Home Security, Event is 0,Parameter 1 is Motion Detection Unknown Location)to its associated node. (2) effective value:10~3600 s 14 (0x0E) When the PIR is triggered,send basic command or not。...
  • Page 9 Temperature sensor value change threshold (1)Unit F as default,threshold value=Value. (0xB7) Effective value:1F~144F(0x0001~0x0090.) 5(%) Humidity sensor value change threshold effective value: 0~80%(0x00~0x50) ;when it is set to (0xB8) be 0,this threshold value doesn’t work 50 (lux) Light sensor value change threshold (0xB9) effective value:0~30000lux (0x0000~0x7530);when it is set to be 0,this threshold value doesn’t work...