Page 1
Operation & Maintenance Manual WB-4000-D Visit our Website for more information on this product www.diversitech.ca 1200 55 Avenue, Montreal, Quebec H8T 3J8 Tel: 1.800.361.3733 | Fax: 1.514.631.9480 | info@diversitech.ca...
Page 2
By nature and variety of dusts, it is impossible to list all potential hazards related to dust control equipment or systems. Therefore, it is imperative that the application and use of this equipment be discussed with an DIVERSITECH distributor, and that this manual is read in its entirety and all personnel involved with this equipment are instructed to comply with the statements pertaining to safety.
The dust is caught by the downward flow and once again moved towards the settling chamber. The dust drawer of the DIVERSITECH Collector contains no airflow inlets or outlets. In fact, airflow is never close to the dust drawer. This eliminates the possibility of re-entrainment...
Initial Installation Considerations The location of the unit(s) must be planned to maximize effective operation, service and maintenance. Should questions arise or assistance is needed consult your DIVERSITECH distributor. After the installation, clearance must be available to service the following components: 1.
cartridge filters and cause excessive differential pressure across the filters resulting in greatly reduced air flow along with premature filter replacement. Note: The air line must be free of oil and water. Oil and/or water will destroy cartridge filters. A customer supplied regulator with a 160 PSI gage must be installed to monitor air pressure. Prior to the final connection of the air line to the collector manifold, the air line should be purged.
Rotate filter slightly to assure no binding and proper location on the flange. Most DIVERSITECH dust collectors use two filters, stacked vertically on each venturi. Position second filter directly on top of first filter, gasket side down and centered vertically with lower filter.
Precautions might be needed to prevent dusting. Maintenance Safety Care with the design of DIVERSITECH collectors has minimized safety hazards for the maintenance and production personnel. Caution: Personnel involved with the DIVERSITECH collector must be familiar with...
Maintenance Procedures With sound periodic and routine maintenance programs you will receive a long service life from your DIVERSITECH collector. Schedules should be changed as a result of experience, determined after a reasonable period of operation. IMPORTANT: Please remove the spark baffle filters in each booth on a monthly basis and wash with detergent.
Note: Be certain the compressed air is off and the pressure relieved before servicing any components that contain compressed air. 6. Follow the manufacturer’s maintenance schedule for the compressed air filters. 7. Tighten the couplings of the valves for the reverse jet pulse cleaning. 8.
Page 11
Note: Discard filters according to all local codes and regulations. Please help protect the environment. Follow filter installation instructions on page 7 to replace filters. Trouble Shooting Guide Symptom Possible Cause Remedy Blower does not start. a. Open electrical supply circuit. Trace circuit back from correct interruption.
Page 12
replaced. per instructions on page 11. Symptom Possible Cause Remedy e. Compressed air volume Increase available air volume. Refer to inadequate. page 5. f. Compressed air pressure Increase air pressure to Maximum of inadequate. 100 PSI. g. Compressed air contaminated with Eliminate source of contamination and oil or water.
Page 13
REPLACEMENT PARTS LIST DIVERSITECH MODEL WB-4000DCA PART DESCRIPTION PART NO. QTY. PER UNIT Filter, Cartridge 351D91A3292 2493 X each Plate, Filter Cap with gasket 1222 X each “T” Handle, Filter Clamp 1224 X each “T” Handle, Access Door Latch 1023...
Page 14
LIMITED EQUIPMENT WARRANTY For a period of 2 years from the date of purchase, all Diversitech products are warranted to be free from defects in material, workmanship, and construction, when used in accordance with installation, maintenance instructions, and expressly stated proper use application(s). Diversitech Inc.
Need help?
Do you have a question about the WB-4000-D and is the answer not in the manual?
Questions and answers