Hydraulic Kit - EverHot BL1 Series Technical Manual

Forced circulation systems
Table of Contents

Advertisement

Application
As a pump, regulator and air venting valve in solar heating systems.
With the hydraulic kit, hydraulic balancing, flow measurement and venting can be performed directly in
the station.
The built-in SETTER Inline UN allows the required quantity of fluid in the primary circuit to be exactly
• Rugged
design
Operation
The flow-rate measurement is based on the proven principle of a baffle float.
The basis for the air venting are special flow technology measures which accumulate the air in the top
of the venting space, from where it can be released from time to time. At the same time, acts as a check
on whether air is building up in the system. There are no
Mechanical parts, so the design ensures a long service life.

Hydraulic kit

and simply set and checked. The continuous venting system meets the most
demanding requirements and keeps the system free of air.
Systems which are correctly balanced hydraulically and air-free guarantee
optimal energy extraction, and are thus more cost-effective in the sense of the
energy-saving directives laid down by law.
Using the scale, which is pre-calibrated for glycol, the technician can set and
check the exact flow-rate values on-site. Neither training courses nor expen-
sive measuring devices are required. Installation and venting can be carried
out by one person working unaided.
Installation position
The solar station must be mounted vertically to ensure problem-free function-
ing of the venting unit.
Advantages
• Cost-effective installation and filling
• Multi-functional ball valve, which greatly simplifies the filling and draining of
the system
• Collector and reservoir sections can be separated for installation work
• Straightforward pump replacement (suction and pressure side can be shut off)
• Precise and rapid regulation adjustments, requiring no diagrams, tables or
expensive measuring devices
• Function checking using the direct flow rate indicator in the SETTER Inline UN
• Visual scale in l/min pre-calibrated for glycol mixes u=2.3 mm
• Constant air release while system is running
• Straightforward venting directly in the station
• Can be connected to any readily-available controller
• Reliable operation, and maintenance-free