9. Troubleshooting

Fault
Cause
Engine does not start
Automatic oil cut-out has not
responded
Spark plug fouled
No fuel
Generator has too little or no
Controller or capacitor defective
voltage
Overcurrent circuit-breaker has
triggered
Air filter dirty
14
Remedy
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / have the petrol cock
checked
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter