Lumiax Magic-E Series User Manual

Lumiax Magic-E Series User Manual

Mppt solar controller

Advertisement

www.lumiax.com
1.03.02.10046-1
Lumiax
Magic your solar life
Magic-E series
MPPT Solar Controller
12/24V,30/40A,
390/520/780W/1KW
MENU
OK
User Manual
User Manual_Magic-E series_KE
CE, Rohs, ISO9001:2015
Subject to change without notice!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magic-E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Lumiax Magic-E Series

  • Page 1 1.03.02.10046-1 Lumiax Magic your solar life Magic-E series MPPT Solar Controller 12/24V,30/40A, 390/520/780W/1KW MENU User Manual User Manual_Magic-E series_KE CE, Rohs, ISO9001:2015 Subject to change without notice!
  • Page 2: Table Of Contents

    Contents Safety instructions and waiver of liability ....................2 Safety Instructions ................................2 1.2 Liability Exclusion ..................................2 Pruduct Overview ............................Dimensions ..............................4 Structure & Accessor y ..........................5 Structure & Characteristics............................5 4.2 Temperaturre Sensor ...............................6 4.3 RS485 .......................................6 4.4 Optional Accessories ...............................6 Installation ..............................5.1 Installation Notes ................................7 5.2 Mounting Location Requirements ..........................7 5.3 Wiring Specifications...............................8...
  • Page 3: Safety Instructions And Waiver Of Liability

    Dear Clients, Thanks for selecting the Magic-E series solar controller. Please take the time to read this user manual, this will help you to make full use of many advantages the controller can provide your solar system. This manual gives important recommendations for installing and using and so on. Read it carefully in your own interest and pay attention to the safety recommendations in it please.
  • Page 4 2, Over view Magic-E series solar controller is based on an advanced maximum power point tracking (MPPT) technology developed, dedicated to the solar system, the controller conversion efficiency up to 98%. It comes with a number of outstanding features, such as:...
  • Page 5 High Voltage Strings and Grid-Tie Modules Another benefit of MPPT technology is the ability to charge batteries with solar arrays of higher nominal voltages. For example, a 12 Volt battery bank may be charged with a 12-, 24-, 36-, or 48-Volt nominal off-grid solar array.
  • Page 6: Pruduct Overview

    2.3 MPPT—Four Charging Stage Magic series controller has a 4-stage battery charging algorithm for rapid, efficient, and safe battery charging. U(V) Equalize Charge 14.8V 14.5V 13.7V Night MPPT Boost Float Night Charge Charge Charge TIME MPPT Charge In this stage, the battery voltage has not yet reached boost voltage and 100% of available solar power is used to recharge the battery.
  • Page 7: Dimensions

    3, Dimensions Unit:mm 63 MT3010-E(-BT/IoT) 63 MT4010-E(-BT/IoT) Φ4.5 MENU MT4010-E(-BT/IoT) MT3010-E(-BT/IoT)
  • Page 8: Structure & Accessor Y

    4, Structure & Accessor y Structure & Characteristics ①Heat Sink —dissipate controller heat ②Plastic Case —Internal protection ③LCD —Display settings and operating status, system parameters ④Key: MENU、OK ③ Set and view the operating parameters ⑤RJ11 interface MENU —Connecting monitoring devices ⑥Temperature Sensor Port —Collect temperature information, Temperature compensation.
  • Page 9: Rs485

    4.3 RS485 The charger is equipped with a RS485 port with RJ11 sockets, the RJ11 interface is defined as follows: Pin No. Definition 1 2 3 4 5 6 RS485-A RS485-B RJ11 for controller Protocol applicable to this controller: Modbus Communication Protocol V3.9 The RS485 interface on this charger is not galvanically isolated and can not be grounded.
  • Page 10: Installation

    5, Installation CAUTION: Please read all instructions and precautions in the manual before installing! It is recommended to remove the acrylic protective film covering the LCD screen before installation. 5.1 Installation Notes ⑴The solar charge controller may only be used in PV systems in accordance with this user manual and the specifications of other modules manufacturers.
  • Page 11: Wiring Specifications

    5.3 Wiring Specifications Wiring and installation methods must comply with national and local electrical specifications. The wiring specifications of the solar, battery and loads must be selected according to rated currents, and see the following table for wiring specifications: Batter y wire Rated Solar wire Load wire...
  • Page 12: Grounding

    WARNING: Risk of electric shock! Exercise caution when handing solar wiring. The solar PV array can produce open-circuit voltages in excess of 100V when in sunlight. Pay more attention to it. WARNING: Risk of explosion! Once the battery's positive and negative terminals or leads that connect to the two terminals get short-circuited, a fire or explosion will occur.
  • Page 13: Operation

    6, Operation 6.1 LCD Display 6.1.1 Status Description Item Icon Status Daytime, not charging Daytime, charging PV array Night PV voltage、 current and ampere hours The total charge ampere hours of the solar panel Batter y capacity Batter y voltage(Programmable LVD) Batter y current Batter y state of charge(in %) Batter y...
  • Page 14 6.1.2 The interface automatically cycles 6.1.3 Press OK to browse the interface...
  • Page 15: Key Function

    6.1.4 Fault indication Status Icon Description Load off, fault icon display, load icon flashes, Short circuit the LCD screen displays E1 Load off, fault icon display, load icon flashes, Over current the LCD screen displays E2 Batter y level shows empty, fault icon display, Low voltage batter y frame flashes, the LCD screen displays E3 Batter y level shows full, fault icon display,...
  • Page 16: Parameters Setting

    6.3 Parameters setting When the icon appears in the display interface, it means that the parameters can be set. Long press the MENU key for 1s, then icon flashes, press OK to change the parameter. 6.3.1 Low voltage protection When the LCD shows as the left, press the MENU key for 1s, the icon flashes, you can set the controller low voltage protection.
  • Page 17 6.3.4 Batter y type When the LCD shows as the left, press the MENU key for 1s,the icon flashes , you can set the batter y type. Display Batter y type GEL(Default) Liquid Lithium 1.Charging Voltage Parameters(Liquid, GEL, AGM) When choosing Liquid, GEL or AGM for batter y type, the parameters of boost, equalization float charge voltage can be set by mobile phone APP, RS485 or Wechat APP.
  • Page 18: Protections, Troubleshooting And Maintenance

    2.Dusk to Dawn or Evening mode When the load is set to Dusk to Dawn or Evening mode, the Day/Night threshold voltage and the Day/Night delay t can be set b the mobile phone APP, RS485 or Wechat APP, and the load can be turned on or off by the test function during the day charging process.
  • Page 19: Protection

    7.2 Protection Protection Description The controller will limit charging power in rated charge power. PV Over Current An over-sized PV array will not operate at maximum power point. When PV short circuit occurs, the controller will stop charging. PV Short Circuit Remove it to start normal operation.
  • Page 20: Technical Data

    8, Technical Data Item MT3010-E MT4010-E MT3010-E-BT MT4010-E-BT Max Charging Current System Voltage 12V/24V automatical recognization MPPT Charging Voltage before boost or equalization charging stage Boost Voltage 14~14.8/28~29.6V @25℃(default: 14.5/29V) Batter y Equalization Voltage 14~15.0/28~30V@25℃(default: 14.8/29.6V)(Liquid, AGM) Parame- Float Voltage 13~14.5/26~39V @25℃(default: 13.7/27.4V) ters Low Volt.
  • Page 21 9.Conversion Efficiency Cur ves Test conditions:lumination intensity: 1000W/m² Temperature: 25℃ Model:MT3010-E(-BT/IoT) Conversion Efficiency Curves Solar Module MPP Voltage 17V/34V Charging Power(W) Conversion Efficiency Curves Solar Module MPP Voltage 34V 51V Charging Power(W)
  • Page 22 Model:MT4010-E(-BT/IoT) Conversion Efficiency Curves Solar Module MPP Voltage 17V/34V Charging Power(W) Conversion Efficiency Curves Solar Module MPP Voltage 34V 51V 1040 Charging Power(W)

This manual is also suitable for:

Mt3010-eMt4010-eMt3010-e-btMt4010-e-bt

Table of Contents