Tatsuta Electric Wire & Cable AD-AS-1LCM-A Operation Manual

Water leakage location detector

Advertisement

Quick Links

TTS-KS-W5010-1
Water Leakage Location Detector
AD-AS-1LCM-A
Operation Manual
TATSUTA Electric Wire & Cable Co., Ltd.
Electronics Division
System Department

Advertisement

Table of Contents
loading

Summary of Contents for Tatsuta Electric Wire & Cable AD-AS-1LCM-A

  • Page 1 TTS-KS-W5010-1 Water Leakage Location Detector AD-AS-1LCM-A Operation Manual TATSUTA Electric Wire & Cable Co., Ltd. Electronics Division System Department...
  • Page 2 <<<Important Safety Instructions!!>>> Warning Erroneous operation of this water leakage detector not complying with the warning labels or the following warnings may not only lead to possible fatality or serious injury, but also fire, electric shock or failure. Warnings! Strict Prohibitions! □...
  • Page 3: Table Of Contents

    à Attached Drawing 1 Outside Dimensions of Water Leakage Location Detector (AD-AS-1LCM-A) à Attached Drawing 2 Explanation of Individual Parts of Water Leakage Location Detector AD-AS-1LCM-A) à Attached Drawing 3 Explanation of Operational Setting Switches of Water Leakage Location Detector (AD-AS-1LCM-A) à...
  • Page 4: Explanation Of Individual Parts Of Water Leakage Location Detector

    First of all, thank you very much for purchasing the Water Leakage Detector AD-AS-1LCM-A. Before using, read this operation manual carefully to ensure correct operation. Keep this manual in a convenient place for quick reference. 1. Explanation of Individual Parts of Water Leakage Location Detector Water leakage location detectors (AD-AS-1LCM-A)has functions in Drawing 1.
  • Page 5: Installation And Handling Precautions

    2.Installation and Handling Precautions 2-1 Installation The Water Leakage Position Detector (AD-AS-1LCM-A) shall be securely installed in a strong housing, on the wall, etc. inside a building.) Be sure to follow the instructions below when installing this product. 1) Avoid installing the detector in any location subject to high temperature and high humidity, excessively dusty environments and corrosive gas environments.
  • Page 6: Configuration Of Water Leakage Location Detecting System

    Triplex, single wiring conductor: φ0.8mm min. and 100m max. in length Drawing 2 Water Leakage Location Detecting System 5. External Connection AD-AS-1LCM-A has a terminal block as shown in Drawing 3. (Make connections securely in conformance to Sections 1 to 5.) Terminal block (M3) Power...
  • Page 7 The structure of the Water Leakage Sensor (AD-LS Sensor) used for the Water Leakage Location Detector (AD-AS-1LCM-A) are shown in Drawing 4 and Table 4. Shapes and functions of each wire vary, so care should be taken when connecting to the detector. Refer to Drawing 5 Incorrect wiring will result in inaccurate indication of water leakage locations or break alarm output.
  • Page 8: Control Output Contact Connection

    5-4 Control Output Contact Connection There are outputs for water leakage and break output connections (Contact a), use them if external control is needed. (Refer to Drawing 6.) Power source Sensor Water leakag Break C-LOOP AC85~264V - Water leakage Sensor Break contact Power source 4-20mA output...
  • Page 9: Water Leakage Location Data Output Connection

    5-5 Water Leakage Location Data Output Connection 5-5-1 Connection The AD-AS-1LCM has a function that outputs the water leakage location by DC electrical current. *Use an analog input device with an input resistance of 500 Ω or lower. Power Sensor Water leakage Break C-LOOP...
  • Page 10: Operation Check

    6. Operation Check 6-1 Power-On When the detector is powered on, the Power Indicator LED and the 7-segment LED light up. (Refer to Drawing 12.) In the case that the LED does not light up, the detector may be out of order. Power off the detector promptly and contact the manufacturer.
  • Page 11: Operation Chart

    7. Operation Chart 7-1 Standard Operation Chart (Factory setting) Refer to Drawing-15 for the operation chart. Power Lighting up Power Indicator LED Lighting out Water leakage detection function Break detection function Lighting up Flashing Alarm Indicator LED Lighting out Lighting out Lighting out Buzzer Stop Switch Buzzer sounding...
  • Page 12: Operation Chart When Alarm Hold Setting Is Activated

    7-2 Operation Chart When Alarm Hold Setting is Activated Changing operational setting switches activates the alarm hold setting for indication and control output contacts. For the operation chart, refer to Drawing 18. NO.2 ON ⇒ The condition is changed to that in which the alarm hold setting for the water leakage location indication is activated NO.3 ON ⇒...
  • Page 13: Indication Of Detector Number

    The detector number is indicated on the leftmost 7-segment LED. *The factory setting is 0 (no indication). Indication of detector number Detector Number 漏水位置検知器 Setting Switch AD-AS-1LCM-A 電源 警報 ブザー停止 警報解除 TATS UTA Ele c tr ic Wir e & Cable Co .,Lt d Drawing 19 Indication of Detector Number 9.
  • Page 14: Buzzer Setting

    10. Buzzer Setting Turning the No.1 operational setting switch ON to set the buzzer to constant sound. (Refer to Attached Drawing 21.) NO.1 ON ⇒ Sounding of buzzer is prevented. Drawing-21. Buzzer Setting 11. Specifications 11-1. Ratings For ratings, see Table 2. Table 2 Ratings Item Specifications...
  • Page 15: Specifications

    11-3 Performances For performance parameters, refer to Table-4. Table 4 Performances Item Specifications Number of sensor circuits Length of sensor connection 1 to 250m Detecting sensitivity level Standard High Highest setting Water leakage detection 10kΩ±20% 25kΩ±20% 50kΩ±20% 100kΩ±20% sensitivity Sensitivity in the case of 16kΩ±20% 37kΩ±20% 68kΩ±20%...
  • Page 16 Attached Drawing-1 POWER ALARM BUZZER RESET STOP - Approved by Checked by Prepared by Water Leakage Location Detector Scale - / - AD-AS-1LCM-A Unit Appearance Dimension Drawing Prepared on 2010.04 TTS-KS-W3285-0 Tatsuta Electric Wire & Cable Co., Ltd.
  • Page 17 (*Contact: 1a) (*Contact: 1a) AC85V~ - AC264V Approved by Checked by Prepared by Scale - / - Explanation of various parts of Unit the Water Leakage Location Detector AD-AS-1LCM-A Prepared on 2010.04 Tatsuta Electric Wire & Cable Co., Ltd. TTS-KS-W3286-0...
  • Page 18 If it is changed to no function status, no corresponding operation is activated ,so care should be taken. Approved by Checked by Prepared by Scale -/- Water Leakage Location Detector AD-AS-1LCM-A Unit Operation setting switch instructions 2010.04 Prepared on TTS-KS-W3287-0 Tatsuta Electric Wire & Cable Co., Ltd.
  • Page 19 4-20mA output is out of order. Lighting Lighting Lighting Lighting Lighting Alarm LED status Flashing Approved by Checked by Prepared by Scale -/- Water Leakage Location Detector AD-AS-1LCM-A Unit Indication instruction-1 2010.04 Prepared on TTS-KS-W3288-0 Tatsuta Electric Wire & Cable Co., Ltd.
  • Page 20 The detector number is indicated on the leftmost 7-segment LED. (1 to 9 and A, B, C, D, E, F can be indicated.) *The factory setting is 0 (no indication). Approved by Checked by Prepared by Scale -/- Water Leakage Location Detector AD-AS-1LCM-A Unit Indication instruction-2 2010.04 Prepared on Tatsuta Electric Wire & Cable Co., Ltd.

Table of Contents