1)
Adjust the fl ow rate in the direction as indicated by the arrow.
2)
Turn the fi lter case in the direction as indicated by the arrow, then take it out.
3)
Move the blue switch to OPEN, then you can open the motor body, on the contrary the
motor body is locked.
4)
Turn the motor body in the direction as indicated by the arrow, then take it out.
5)
Ciean and change the impeller after taking out.
6)
Make sure to put the O-ring at the right place (as shown in the pic).
Winter care
•
Take the pump out of the water.
•
Thoroughly clean the pump (see section 6.0)
•
Check the pump for damage.
•
Caution: Never immerse the connecting plug!
•
Store the ump in frost-free conditions, in a container with water if possible.
Pump does not work
Noise
Insuffi cient water displace-
ment
Trouble Shooting
Possible Cause
•
No power
•
Burned
•
Rotor is blocked
•
Running without water
•
Filter housing is blocked or
shaft is broken
•
Ceramic shaft or bearing:
Wearing occurs
•
Impeller broken
•
Flow rate valve closed
•
Filter housing is clogged
•
Low voltage
Possible Solution
•
Plug in
•
Clear blockages
•
Plug in again and add water
•
Clean blockages after ope-
ning
•
Change the shaft or bearing
•
Change impeller
•
Open the fl ow rate valve
•
Clean blockages and plug in
•
Change to right voltage
8