    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table of Contents 1. Document Overview ........................9 1.1. Document identification ....................... 9 1.2. Disclaimer ......................... 9 1.3. Copyrights ......................... 9 1.4. Precautions ........................10 1.5. Symbols ........................... 11 2. Product Overview ........................12 2.1. Package Contents ......................12 2.2.
  • Page 3 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5.2.2. Output ASI ......................66 5.2.3. Output IP ......................66 5.2.4. Input TS ........................ 68 5.3. System Settings ......................... 68 5.3.1. System - Overview ....................68 5.3.2. System - Time ......................68 5.3.3. System - Network Interface ..................69 5.3.4.
  • Page 4 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 F.3. Decoder configuration ...................... 118 F.4. Encoder configuration ...................... 119 G. Use Cases ..........................122 G.1. 4k ..........................122 G.1.1. Overview ......................122 G.1.2. Configuration ....................... 123 G.2. 4k and modulator ......................125 G.2.1. Overview ......................125 G.2.2.
  • Page 5 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 List of Figures 1.1. Direct current symbol ........................ 11 1.2. Alternating current symbol ......................11 1.3. Ground symbol ......................... 11 1.4. Blocked trash ..........................11 2.1. Front View Interface ........................13 2.2. Rear View Interface ........................14 2.3.
  • Page 6 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 List of Tables 1.1. Document Identification ....................... 9 2.1. Front View Interface ........................13 2.2. Rear View Interface ........................14 2.3. Power Switch ........................... 15 2.4. I/O Base Interface ........................16 2.5. I/O Base Alarm Connector Pinout description ................. 17 2.6.
  • Page 7 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5.33. Global ........................... 64 5.34. DVB compliance ........................65 5.35. Carrier ID ..........................65 5.36. SBTVD FullSeg compliance ...................... 65 5.37. Carrier ID ..........................66 5.38. Output ASI ..........................66 5.39. Output IP ..........................66 5.40.
  • Page 8 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 I.16. Specification - Configuration and management interfaces ............... 140 I.17. Specification - System ......................141 I.18. Specification - Licenses ......................142 I.19. Specification - Physical ......................144 I.20. Specification - Environmental and Power ..................144 I.21.
  • Page 9: Document Overview

    1.3. Copyrights Notice The CM5000 is not designed or intended to violate any other entity's copyright or other IP (Intellectual Property) rights. Each CM5000 user may only use their CM5000 in conjunction with materials legally owned or licensed by such user, and only to the extent that such ownership or license rights permit such use.
  • Page 10: Precautions

    Never expose your device to rain, use it near water, or in damp or wet conditions. Never place objects containing liquids on the CM5000, as they may spill into its openings; doing so increases the risk of electrical shock, short- circuiting, fire or personal injury.
  • Page 11: Symbols

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Warning This product contains a lithium battery. The lithium battery may explode if it is incorrectly replaced. This battery must be replaced only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
  • Page 12: Product Overview

    2.1. Package Contents Before continuing, please check the contents of the product package. This product package should contain the fol- lowing items: • One (1) CM5000, • One (1) Power Cord, • One (1) CD ROM, • This User's Manual.
  • Page 13: Front View

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.2. Front View This figure describes the front interface of the CM5000. Figure 2.1. Front View Interface Table 2.1. Front View Interface Front Panel Air Intakes Front Panel Interfaces FP are described in Section 4.2, “ Front Panel ”...
  • Page 14: Rear View

    UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.3. Rear View This figure describes the generic rear interfaces of the CM5000. Depending on your exact model and the options purchased, the extended slots may contain additional connectors which will be described in the next paragraphs. Figure 2.2. Rear View Interface Table 2.2.
  • Page 15: Power Switch

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.4. Power Switch This figure describes the location of the Power switch of the CM5000. Figure 2.3. Power Switch Table 2.3. Power Switch Use this switch to turn ON the unit. Switch it Power Switch back to the original position to turn OFF the unit.
  • Page 16: I/O Base Interfaces

    This DB9 connector is dedicated to input and output discrete signals. 2.5.1. I/O Alarm Connector The CM5000 provides the user with 4 external GPIOs : 2x IN and 2x OUT. GPO are dry-loops based on electro-mechanical relays, AC/DC 1A / 24V max.
  • Page 17: I/O Base Alarm Connector Pinout

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Both have a 2KV isolation with the platform mechanical and electrical ground. GPO dry-loops default to OFF (opened) when the unit is powered-up. Those GPIOs are available on a 9 points female Sub-D connector : Figure 2.5.
  • Page 18: Extended Interfaces

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.6. Extended Interfaces Depending of the hardware options that you've purchased, some of the interfaces may be accessible on I/O Extended Interfaces ([X], [VA], [VB]). www.ateme.com Page 18...
  • Page 19: Extended L-Band Modulator Interfaces

    Figure 2.6. Extended L-Band Modulator Interfaces Table 2.6. Extended L-Band Modulator Interfaces XLB1 Encoder SDI IN Use this BNC connector to input the SDI video signal into the CM5000. 75Ω Encoder Use this BNC connector to output the encoded bitstream. It...
  • Page 20: Extended If Modulator Interfaces

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.6.2. Extended IF Modulator Interfaces This figure describes the Extended IF Modulator interfaces of the CM5000. Figure 2.7. Extended IF Modulator Interfaces Table 2.7. Extended IF Modulator Interfaces Encoder Use this BNC connector to input the...
  • Page 21: Extended Asi/Sdi Interfaces

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.6.3. Extended ASI/SDI Interfaces Next figure describes the ASI/SDI extended interface of the CM5000. Figure 2.8. Extended ASI/SDI Interfaces Table 2.8. Extended ASI/SDI Interfaces Use this BNC connector to input the chan- Channel 1 SDI Input nel 1 SDI video signal into the CM5000.
  • Page 22: Extended Aes Audio Interfaces

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.6.4. Extended AES Audio Interfaces This figure describes the AES Audio extended interface of the CM5000. Figure 2.9. Extended AES Audio Interfaces Table 2.9. Extended AES Audio Interfaces AES Audio Input Use this DB25 connector to input up to 8 AES audio pairs.
  • Page 23: Extended Aes Audio Connector Pinout

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Figure 2.10. Extended AES Audio Connector Pinout Note To input audio with XLR connectors, use the XLR to DB25 cable provided separately (Ref: AEXT- CBL). www.ateme.com Page 23...
  • Page 24: Extended Analog Audio Interfaces

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.6.5. Extended Analog Audio Interfaces This figure describes the Analog Audio extended interface of the CM5000. Figure 2.11. Extended Analog Audio Interfaces Table 2.10. Extended Analog Audio Interfaces Analog Audio Input Use this DB25 connector to input up to 4 analog audio pairs.
  • Page 25: Extended Analog Audio Connector Pinout

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Figure 2.12. Extended Analog Audio Connector Pinout Note To input audio with XLR connectors, use the XLR to DB25 cable provided separately (Ref: AEXT- CBL). www.ateme.com Page 25...
  • Page 26: Serial Number

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 2.7. Serial Number Serial Number and Production Code Markings are located in the rear side [SN]. Figure 2.13. Serial Number and Production Code Markings www.ateme.com Page 26...
  • Page 27: Ventilation

    Figure 2.14. Cool air intakes on the front panel Figure 2.15. Warm air outputs on the rear panel Place the CM5000 in a well-ventilated space, and allow ideally up to 10cm of free space on all sides of the CM5000 so increasing air circulation and cooling.
  • Page 28: Installation

    • For Stand Alone installations, place the unit on a stable surface. It requires clearance above and on each side to allow for cooling. • Alternatively, for Rack installations, mount the unit in a standard 19-inch rack. The CM5000 requires 1U of vertical space.
  • Page 29: Quick Start

    • The front panel selection menu appears when the unit is up and running. 3.2. Quick start Step 1: Configure management IP address Use the front panel to configure the MGT IP address of the CM5000: [CM5000 IP address] (System -> Network - > MGT -> IP). Step 2: Open a web browser On a computer connected to the same network, launch your favorite web browser and browse to http://[CM5000 IP address].
  • Page 30: User's Interfaces

    4.2. Front Panel The CM5000 has a local LCD and keypad interface allowing a simple management of the unit. The control buttons and LCD provide an easy method of setting the network interface addresses and default gateway parameters directly from the front of the CM5000 System without using a management computer.
  • Page 31: Lcd

    The TFT [FP5] displays the video input signal and its format. 4.2.4. Keypad The Keypad is used for configuration when navigating the local setup menu of the CM5000. Use the directional keys, [FP8] to [FP11], to navigate through the different menus.
  • Page 32: System

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Temperature Unit Uptime Channel SD Aspect Ratio CH 1 pairs 1-4 SDI source CH 1 pairs 5-8 SDI source AES inter- Monitor AES pairs 1-4 face source Audio monitoring AES inter- AES pairs 5-8 face source...
  • Page 33 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Version Software Build Update from USB Hardware slots description and status License BISS-E Modulator Restore state Yes/No Enabled Redundancy Channel 1 Master/Slave Destination Text screen Screens timeout Video screen Monitor SDI 1 Monitor SDI 2...
  • Page 34: Front Panel Menu - Service Main

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table 4.3. Front Panel Menu - Service Modulator Enabled Transmit Mode Output Power slot Output Power H (dBm) Output Power L (dBm) BUC's LOF (MHz) Frequency (MHz) Symbol Rate (MBd) Standard Service Modulator Type Roll-off...
  • Page 35: Mpeg-4 Avc

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Network ID Network Name DVB-SI Tables Carrier ID Bitrate Occupancy Min Bitrate PCR on Modulator Output Ip 1 Format Connector Autosense Input Emulation Frame Syn- chronization Format Processing Video MPEG-4 AVC MPEG-2 HEVC TS PID...
  • Page 36: Teletext

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Input Source Processing Format Teletext SCTE-35 DVB Subtitles SMPTE-2038 STD-B24 Input Clock Source Source Table 4.5. Front Panel Menu - Service Remuxer Enabled Yes/No Standard Packet Size Bitrate (kbps) Table Bitrate (kbps) Enable SI/PSIP tables...
  • Page 37: Web Gui

    • use a cross-over Ethernet cable to connect the devices directly to the controlling computer, • use straight through Ethernet cables to connect the devices to a hub or switch. Configure both the management computer and CM5000 to be on the same subnet. To do this, two solutions are possible: •...
  • Page 38: Web Gui Overview

    The login dialog box will be displayed in your OS language. It may differ from the above figure. 4.3.2. Web GUI Overview Once logged in, the web server of the CM5000 will display its management environment. This environment is divided into 2 main areas: •...
  • Page 39: Status Tab

    • [GC1]: Button used to load a preset into the web GUI editor. The preset can be loaded from a file, from slots stored on the CM5000 or from a preset using factory settings. This action does not disrupt nor reconfigure the CM5000.
  • Page 40: Remuxer Tab

    2019-07-08 • [GC2]: Button used to save the content of the web GUI editor to a file or to a slot stored on the CM5000. • [GC3]: Button used to discard non applied changes done in the web GUI editor. After this action, the web GUI editor will show the settings that are being used by the CM5000.
  • Page 41: Web Interface - Remuxer Tab

    CM5000 or from a preset using factory settings. This action does not disrupt nor reconfigure the remuxer. • [GC2]: Button used to save the content of the web GUI editor to a file or to a slot stored on the CM5000.
  • Page 42: System Tab

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Note If you want to import a preset from a file to a slot, you can load it using [GC1], then save it using [GC2]. Afterward, you may optionally use the discard button [GC3] to show the settings the remuxer is using.
  • Page 43: Settings Package Configuration

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Settings package The settings package is used to backup/restore or transfer from one unit to another most of the settings of the encoder. To create a settings package: • Click on [GC2]. • A popup will appear. Choose the item(s) you want to be saved into your package. Click OK.
  • Page 44: Simple Setting Edition

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Warning Importing channel presets or remuxer presets will also erase the current configuration and may restart the encoder. Note For security reasons, VPN certificates, SNMP community strings, BISS injected id, GUI password and the license file cannot be exported.
  • Page 45 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 • Click on [GS5] to apply your changes or on [GS4] to cancel them. www.ateme.com Page 45...
  • Page 46: Settings

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5. Settings This chapter lists all configurable parameters that can be set through the GUI Interface. Some are not accessible depending on your product or the licenses that you purchased. See the product specification in annexes to check capability of your product.
  • Page 47: Carrier Id

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 TS occupancy min bitrate (number) MPEG ATSC TS compliance ISDB SBTVD FullSeg SBTVD OneSeg TS packet size Null bitrate (number) PMT PID (number) Program number (number) PMT PCR PID (number) PAT TS ID (number) PAT period...
  • Page 48: Output Asi

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Information (string) Longitude (real number) Latitude (real number) ATSC compliance These settings are available when 'TS conformance' is ATSC and PSIP tables are enabled. Table 5.5. ATSC Parameter Value Note None Delivery Cable Terrestrial Channel short name...
  • Page 49 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Available on Output power High (real number) the status page Available on Output power Low (real number) the status page BUC's LOF (number) Frequency (real number) Symbol rate (real number) QPSK 8PSK 16APSK 32APSK 64APSK...
  • Page 50: Output Ip

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 0.15 0.20 0.25 0.35 Tilt (real number) Normal Frame type Short Pilot mode Spectral inversion PL Scrambling Gold Sequence 0..26141 DVB Carrier ID (DVB-CID) These settings are available when a DVB output is enabled. Table 5.8. DVB Carrier ID (DVB-CID)
  • Page 51: Video

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Password enable (string) Only when Protocol is Zixi None Only when Protocol is RTP Columns (number) Only when FEC is 1D or 2D Rows (number) Only when FEC is 1D or 2D Steps (number) Only when FEC is 1D or 2D...
  • Page 52: Video

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 MPEG-4 AVC-I MPEG-2 HEVC 525i 625i 720p@50 720p@59.94 720p@60 1080i@25 1080i@29.97 1080i@30 1080psf@23.976 Input 1080psf@24 1080psf@25 1080p@23.976 1080p@24 1080p@25 1080p@29.97 1080p@30 1080p@50 1080p@59.94 1080p@60 Auto sense Video PID (number) VBR - Quality Capped Rate control...
  • Page 53 The auto sense functionality allows the encoded stream to dynamically adapt to a video input format change, e.g. if the video input changes from 625i to 720p50 the CM5000 will adapt to encode a 720p50 stream. However it imposes some constraints on the configuration. Among others: •...
  • Page 54: Mpeg-4 Avc-I

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Main (4:2:0 8-bit) High (4:2:0 8-bit) High 10 (4:2:0 10-bit) High 4:2:2 (8-bit) High 4:2:2 (10-bit) Automatic Frame Field Only Interlacing mode PAFF MBAFF MBAFF and PAFF Deblocking Deblocking strength (number) Flat Scaling matrices Default...
  • Page 55 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Force AFD emulation Enable picture timing SEI Video Input Picture timing SEI source Date Table 5.13. MPEG-2 Parameter Value Note Main Profile 4:2:2 (using 4:2:0) 4:2:2 Automatic Frame Field Only MBAFF Interlacing mode Frame and Field...
  • Page 56: Colorimetry

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Date Table 5.15. Colorimetry Parameter Value Note Custom SDR WCG ARIB STD-B67 Only when Mode DVB PQ10 Codec is not DVB HDR10 MPEG-2 DVB HLG10 ATSC HDR10 ATSC HLG Auto Color primaries BT 709 BT 2020...
  • Page 57: Audio

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5.1.7. Audio Table 5.16. Audio Parameter Value Note MPEG Layer2 AAC LC (MPEG-4) AAC LC (MPEG-2) AAC HEv1 Codec AAC HEv2 Dolby Digital Dolby Digital Plus Pass-through Mono Dual-mono Only when pass- Non pass-through mode...
  • Page 58: Mpeg Layer2

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Language code None Clean effects Language type Hearing Impaired Visual Impaired Commentary Silence Sine 440Hz Emulation mode Noise Mute TS Emulation forced Delay (real number) Gain (real number) Loudness control EBU R128 Mode ATSC A85...
  • Page 59: Dolby Digital

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 TNS allowed MS allowed Table 5.19. Dolby Digital Parameter Value Note User Metadata Dolby E Ancillary Only when ancillary Program (number) metadata is selected Only when ancil- Last used metadata Reversion mode lary or Dolby E...
  • Page 60 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Copyright bit Original flag Unspecified Dolby Digital surround EX Enabled Disabled Unspecified Dolby headphone mode Enabled Disabled Unspecified Stereo Downmix preference Dolby prologic Dolby prologic II -1.5 Lt/Rt center mix level -3.0 -4.5 -6.0 -infinity -1.5...
  • Page 61: Data

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5.1.8. Data Table 5.20. Data Parameter Value Note Enable Teletext SCTE-35 Type DVB Subtitles SMPTE-2038 STD-B24 Data PID (number) Delay (real number) Clear BISS Stream identifier descriptor Component tag (number) Component descriptor Component tag (number)
  • Page 62: Teletext Filter

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table 5.22. Teletext descriptor Parameter Value Note Enable Initial Subtitle Description Additional Information Program Schedule Hearing Impaired Page (number) Language code Table 5.23. Teletext filter Parameter Value Note Enable Field 1 (pass/dismiss per VBI line)
  • Page 63: Smpte-2028

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 IP source port (number) Only when source is TS and input is IP SYNC Input ASI source Only when source is TS and input is ASI ASI Input TS stream PID (number) Only when source is TS...
  • Page 64: Remuxer Settings

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table 5.30. SCTE-35 GPI source Parameter Value Note Disabled Command source GPI1 GPI2 Command type Insert Out Of Network Insert Type Return To Network Insert Event Id (number) Insert Pre-Roll [4000-95443717] Insert Immediate Insert Break Duration...
  • Page 65: Dvb Compliance

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 MPEG TS compliance SBTVD FullSeg TS packet size Table Bitrate Enable SI/PSIP tables DVB compliance These settings are available when 'TS conformance' is DVB and SI tables are enabled. Table 5.34. DVB compliance Parameter Value...
  • Page 66: Output Asi

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Network name (string) Generated From Input TS 1 From Input TS 2 From Input TS 3 From Input TS 4 From Input TS 5 From Input TS 6 From Input TS 7 From Input TS 8 Table 5.37.
  • Page 67 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Backup IP (IP address) Backup port (number) Protocol Zixi None Only when Protocol is RTP Columns (number) Only when FEC is 1D or 2D Rows (number) Only when FEC is 1D or 2D Steps (number)
  • Page 68: Input Ts

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5.2.4. Input TS Table 5.40. Input TS Parameter Value Note Enable Input Internal SYNC Input ASI Source Only when Input ASI is selected ASI Input Channel 1 - Main Internal Source Only when Input Internal is selected...
  • Page 69: System - Network Interface

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 NTP enable NTP address (IP address) PTP enable PTP interface Stream 1 Stream 2 Domain number (number) 5.3.3. System - Network Interface Table 5.43. Interface Parameter Value Note Interface Stream 1 Stream 2 Disable Status...
  • Page 70: System - Network Route

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 5.3.5. System - Network Route Table 5.45. Route Parameter Value Note Disable Default Type Host Interface Stream 1 Stream 2 Destination (IP address) Netmask (netmask) Gateway (IP address) 5.3.6. System - Network VPN Table 5.46. Route...
  • Page 71: System - Assets

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Preset Slot 1 .. Slot 128 [enable] tickbox to enable/disable the automation functionality. [Add rule] button to create an automation rule. When enabled the automation functionality will look for a rule matching the SDI input video format and then will load its corresponding channel preset.
  • Page 72 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Fonts The following font file formats are supported: • TrueType font file (.ttf) • TrueType Font collection (.ttc) • Microsoft Windows bitmap font file (.fon) • OpenType font file format (.otf) Public keys CSV Warning Only CSV files are supported.
  • Page 73: System - Alarms

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 -----END PUBLIC KEY-----"; IRD-B PKCS8 5.3.9. System - Alarms Table 5.49. Alarms names Alarm name Active condition (when applicable) The audio signal contains silence for longer than Audio Signal Inactive 10s (per audio track that are not pass-through)
  • Page 74: System - Logs

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 System Power Supply Unit A power supply unit is failing (per power supply unit) Table 5.50. Alarms actions Parameter Value Note Name Disabled Information Level Warning Critical Delay (number) None Activate GPO 1 Activate for Channel 1...
  • Page 75: System - Snmp Service

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Information Warning Critical 5.3.11. System - SNMP Service Table 5.53. Trap target Parameter Value Note State Enabled/Disabled 5.3.12. System - SNMP Trap Target Table 5.54. Trap target Parameter Value Note SNMP v2 trap Type SNMP v2 notification...
  • Page 76: System - Misc Redundancy

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Statmux port (number) 5.3.16. System - Misc redundancy Table 5.58. Misc Redundancy Parameter Value Note Channel 1 Channel Channel 2 Enabled Satus Disabled Master Master/Slave Slave Peer streaming in- Destination (IP address) terface IP address 5.3.17.
  • Page 77: Specific Operations

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 6. Specific Operations 6.1. Installing License In the web GUI, go to the System tab and click License. The upper section is used to update the license settings. To do so, click the Update button. A pop-up should appear asking for a license file. Click on the Browse button to point to it and click Ok to proceed with the update, or Cancel to abort.
  • Page 78: Recovery

    6.3. Recovery If the web GUI becomes unreachable (and you are sure this is not a network problem) or the CM5000 keeps rebooting by itself without allowing you to do anything, it may be due to a corrupted file or settings incompatibility between 2 versions preventing the system to boot normally.
  • Page 79 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 • Step 2: Watch for a Maintenance message displayed on FP5 after a few seconds. • Step 3: Quickly press the validation key (see Section 4.2, “ Front Panel ”) to enter the Maintenance menu.
  • Page 80: Mib User Guide

    A.1. SNMP overview This section applies to the CM5000 version 3.5.2.0 (build 31.3.3.0). It is a guide for interfacing the CM5000 via a NMS, or through simple SNMP commands. The MIB of the CM5000 can be used to control, configure, and monitor the unit.
  • Page 81: Mib Overview

    UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Request rate The CM5000 will process up to 300 requests per second. Walking through the entire MIB may thus take hundreds of seconds. Communities Community strings provide a basic right access mechanism. Two community strings are defined: "public" is associated to Read-Only variables, "private"...
  • Page 82: Main Nodes

    (OID 1.3.6.1.4.1.27338.4.15) kyrion2Conformance (OID 1.3.6.1.4.1.27338.4.1) The CM5000 only exports full compliance group. Please refer to RFC 2580 for more information on that topic. kyrion2Unit (OID 1.3.6.1.4.1.27338.4.2) This node contains information related to the physical unit, such as unit Serial Number (RO), Name (RW) and Model (RO).
  • Page 83 Configuring network interfaces ” and Section A.3.1.8, “ Configuring routes ” for more information. kyrion2Biss (OID 1.3.6.1.4.1.27338.4.7) Used to specify injected IDs. Please note that these fields are Write-Only, but belong to the Read-Write community. The CM5000 can hold two injected IDs. kyrion2Time (OID 1.3.6.1.4.1.27338.4.8) Used to set or get the current date.
  • Page 84 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 kyrion2Preset (OID 1.3.6.1.4.1.27338.4.13) This node is related to preset management. It lists all the configuration slots stored in the unit, and can also be used to edit the slot name. Please note that this node can neither be used to view nor edit configuration slot content, but only its name.
  • Page 85: Preset Editing Guidelines

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 A.2.2. Preset editing guidelines All of the active configuration preset settings are located under the kyrion2ChannelCfgTs node. During the develop- ment phase, the web GUI is a valuable tool to check if the SNMP commands have been accepted by the encoder or not.
  • Page 86: Mib Use Cases

    A.3.1. System A.3.1.1. Identification process The model name and serial number can be retrieved through the nodes kyrion2UnitName and kyrion2UnitSerialNumber. The following example shows the identification process of a CM5000. snmpget -v2c -c public $HOST \ ATEME-KYRION2-MIB::kyrion2UnitName.0 #ATEME-KYRION2-MIB::kyrion2UnitName.0 = STRING: encoder-5 snmpget -v2c -c public $HOST \ ATEME-KYRION2-MIB::kyrion2UnitSerialNumber.0...
  • Page 87 #ATEME-KYRION2-MIB::kyrion2SnmpCommunityReadOnly.0 = STRING: read-only snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2SnmpCommunityReadWrite.0 s "read/write" #ATEME-KYRION2-MIB::kyrion2SnmpCommunityReadWrite.0 = STRING: read/write The CM5000 can send SNMP traps on pre-defined events to up to four targets. The trap targets are defined in the list kyrion2SnmpManager. www.ateme.com Page 87...
  • Page 88 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Warning This list is automatically reorganized so that enabled targets are located on the lowest indexes. Perform- ing several changes in a single SNMP commands has thus an undefined behaviour. The following example empties the list of trap targets, and adds 172.16.1.22:1256 as a new target.
  • Page 89 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 The following example configures Stream 2 IP address to 10.16.127.221/16: snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2NetworkConnectionIsEnabled.3 i 1 #ATEME-KYRION2-MIB::kyrion2NetworkConnectionIsEnabled.3 = INTEGER: true(1) snmpset -v2c -c private $HOST ATEME-KYRION2-MIB::kyrion2NetworkConnectionIsDhcp.3 i 2 #ATEME-KYRION2-MIB::kyrion2NetworkConnectionIsDhcp.3 = INTEGER: false(2) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2NetworkConnectionAddress.3 d 10.16.127.221...
  • Page 90: Channel Presets

    A.3.2. Channel Presets A.3.2.1. Loading/saving channel presets A CM5000 channel configuration is called a "preset". Presets are stored in indexed "slots". These slots must be seen as copies at a given instant of a configuration. There is also a virtual preset slot called "Active configuration" which: •...
  • Page 91: Quality/Latency Mapping

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 The following example reads the name of preset #3, loads it to channel 1 active configuration, and stores it in slot #5. snmpget -v2c -c public $HOST ATEME-KYRION2-MIB::kyrion2PresetPresetName.3 #ATEME-KYRION2-MIB::kyrion2PresetPresetName.3 = STRING: my preset 3 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCommandLoadPreset.1 i 2...
  • Page 92 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 The remaining tables are used to set non compliance specific parameters like PMT/PCR PID or period, BISS mode and key, etc... The following example sets the channel 1 TS bitrate to 20Mbps and switches the compliance to ATSC. (Check...
  • Page 93 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsTsBissMode.1.1 i 2 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsTsBissMode.1.1 = INTEGER: n1(2) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsTsBissKey.1.1 s 0123456789AB #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsTsBissKey.1.1 = STRING: 0123456789AB snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoTsBissIsEnabled.1.1.1 i 1 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoTsBissIsEnabled.1.1.1 =...
  • Page 94 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsOutputIpProtocol.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsOutputIpProtocol.1.1.3 = INTEGER: udp(1) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsOutputIpDestinationAddress.1.1.3.1 \ d 225.10.10.1 # ATEME-KYRION2-MIB::kyrion2ChannelCfgTsOutputIpDestinationAddress.1.1.3.1 = Hex-STRING: E1 0A 0A 01 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsOutputIpDestinationPort.1.1.3.1 u 5000...
  • Page 95 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 The next table, kyrion2ChannelCfgTsOutputDvbsModulationTable, is used to set the modulation type through kyrion2ChannelCfgTsOutputDvbsModulationType. Note kyrion2ChannelCfgTsOutputDvbsModulationState deprecated. kyrion2HardwareModulatorIsMuted instead. Note kyrion2ChannelCfgTsOutputDvbsModulationMode is reserved for futur use. Only CCM is supported at the moment. Finally, the kyrion2ChannelCfgTsOutputDvbsCarrierIdTable table, allows to enable and configure the carrier ID.
  • Page 96: Carrier/Modulation State Mapping

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table A.2. Carrier/Modulation state mapping Carrier/Modulation kyrion2HardwareModulatorIsMuted kyrion2HardwareModulatorIsModulated True(1) Carrier only False(2) False(2) Modulated False(2) True(1) A.3.2.7. Configuring video Configuring video is performed through kyrion2ChannelCfgTsEsVideo sub-tree. The main entry is the kyrion2ChannelCfgTsEsVideo table. It allows to choose the video codec.
  • Page 97 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoInputSdiFormat.1.1.1 i 7 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoInputSdiFormat.1.1.1 = INTEGER: n1080i2997(7) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoInputEmulationMode.1.1.1 i 1 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoInputEmulationMode.1.1.1 = INTEGER: black(1) snmpset -v2c -c private $HOST ATEME-KYRION2-MIB::\ kyrion2ChannelCfgTsEsVideoInputEmulationIsMovingPatternEnabled.1.1.1 i 1 #ATEME-KYRION2-MIB:: kyrion2ChannelCfgTsEsVideoInputEmulationIsMovingPatternEnabled.1.1.1 = \...
  • Page 98 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Then, configure the GOP size to 30: snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoH264GopSizeMax.1.1.1 i 30 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoH264GopSizeMax.1.1.1 = INTEGER: 30 And finally, set the video PID to 300: snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoTsPid.1.1.1 i 300 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsVideoTsPid.1.1.1 = INTEGER: 300...
  • Page 99 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioInputFormat.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioInputFormat.1.1.3 = INTEGER: pcm(1) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioInputSource.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioInputSource.1.1.3 = INTEGER: sdi(1) • Since it is a PCM source, next step is to provide the channel layout: The only supported layouts are given in the table below.
  • Page 100 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Grp1 Ch1&2 Grp1 Ch3&4 Grp2 Ch1&2 Grp2 Ch3&4 Grp3 Ch1&2 Grp3 Ch3&4 10-11 Grp4 Ch1&2 12-13 Grp4 Ch3&4 14-15 The following sample maps Grp2/Ch1&2 to {L,R}, Grp2/Ch3&4 to {C,Lfe} and Grp3/Ch1&2 to {Ls,Rs}. snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioInputSdiEntriesEntries.1.1.3.1 i 4...
  • Page 101: Remuxer Presets

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioAc3BitRate.1.1.3 i 320000 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioAc3BitRate.1.1.3 = INTEGER: 320000 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioAc3IsEnhanced.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioAc3IsEnhanced.1.1.3 = INTEGER: true(1) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioAc3MetadataSourceSource.1.1.3.1 i 2 #ATEME-KYRION2-MIB::kyrion2ChannelCfgTsEsAudioAc3MetadataSourceSource.1.1.3.1 =...
  • Page 102 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpget -v2c -c public $HOST ATEME-KYRION2-MIB::kyrion2PresetRemuxerPresetName.3 #ATEME-KYRION2-MIB::kyrion2PresetRemuxerPresetName.3 = STRING: my preset 3 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2RemuxerCommandLoadPreset.1 i 2 #ATEME-KYRION2-MIB::kyrion2RemuxerCommandLoadPreset.1 = INTEGER: 2 snmpset -v2c -c private $HOST ATEME-KYRION2-MIB::kyrion2RemuxerCommandAction.1 i 2 #ATEME-KYRION2-MIB::kyrion2RemuxerCommandAction.1 = INTEGER: load(2) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2RemuxerCommandSavePreset.1 i 4...
  • Page 103 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 A.3.3.3. Configuring IP outputs This is done in the same way as configuring a channel IP output but with using: • kyrion2RemuxerCfgTsOutputIp as the main entry. • kyrion2RemuxerCfgTsOutputIpDestination table for main/backup parameters. See Section A.3.2.5, “ Configuring IP outputs ”...
  • Page 104 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2RemuxerCfgTsInputIsEnabled.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2RemuxerCfgTsInputIsEnabled.1.1.3 = INTEGER: udp(1) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2RemuxerCfgTsInputSource.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2RemuxerCfgTsInputSource.1.1.3 = INTEGER: asi(1) snmpset -v2c -c private $HOST \ ATEME-KYRION2-MIB::kyrion2RemuxerCfgTsInputAsiChannel.1.1.3 i 1 #ATEME-KYRION2-MIB::kyrion2RemuxerCfgTsInputAsiChannel.1.1.3 = INTEGER: asiSyncIn(1)
  • Page 105: Simple Rpc Guide

    2019-07-08 Appendix B. Simple RPC Guide B.1. Overview This section is a guide for interfacing the CM5000 via simple HTTP requests (GET or POST) in addition to SNMP when a file upload or download is needed. Note All the examples provided in this section are using the command-line application wget, which is avail- able for all major Operating Systems.
  • Page 106 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 wget --post-file=$FILE \ --header 'Content-Disposition: attachment; filename=license.lic' \ http://$HOST/simple-rpc/system/setLicense B.2.1.3. License download Download the license file: wget --content-disposition http://$HOST/simple-rpc/system/getLicense B.2.1.4. Export system settings Export the system settings to the archive $FILE: #Export all settings: wget -O $FILE http://$HOST/simple-rpc/system/export #Export specific settings (e.g.
  • Page 107: Channel

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 B.2.1.5. Import system settings Update the system settings using the settings archive file $FILE: wget --post-file=$FILE \ --header 'Content-Disposition: attachment; filename=$FILE' \ http://$HOST/simple-rpc/system/import Note All the configuration file included in the archive will be imported.
  • Page 108: Remuxer

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 wget -O $FILE http://$HOST/simple-rpc/presets/channel/getSlot/$INDEX Export the factory preset to the file $FILE: wget -O $FILE http://$HOST/simple-rpc/presets/channel/getFactory Import the file $FILE into the slot preset indexed by $INDEX (0 based): wget --post-file=$FILE http://$HOST/simple-rpc/presets/channel/setSlot/$INDEX B.2.3. Remuxer B.2.3.1. Active configuration...
  • Page 109 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 wget --post-file=$FILE http://$HOST/simple-rpc/presets/remuxer/setSlot/$INDEX www.ateme.com Page 109...
  • Page 110: Vpn Guide

    C.1. Overview The CM5000 embeds a Virtual Private Network (VPN) client. It allows the CM5000 to connect to a private network across another one (e.g Internet) and behaving like it is directly connected to the private network. The client is based on the OpenVPN®...
  • Page 111: Client Configuration

    Protocol the proto line of the server configuration. Server address IP address The server address must be reachable by the CM5000 Must be the same as the one defined on Server port the port line of the server configuration Certificate/keys...
  • Page 112: Redundancy

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Appendix D. Redundancy D.1. Overview The aim of the 1+1 IP redundancy functionality is to protect an IP broadcast event from the failure of an encoder, or of a source, without any other monitoring equipment.
  • Page 113 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 • Data inputs are valid. • Outputs are valid. • Outputs are streaming. Reaction time: The required time to mute a stream following an event is at most 750ms. The time to unmute is at most 1250ms.
  • Page 114: Zixi/Arq

    Thus, specific NAT/firewall/routing rules must be established to allow the CM5000 to reach its destination and con- versely, to allow the destination to reach the CM5000. A CM5000 unit can handle up to 8 different destinations. If more are required, a forwarding infrastructure such as Zixi Broadcaster® is required.
  • Page 115: Route Configuration Sample

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 As we can see on the previous figure, the encoder must be able to reach the same destination through two network interfaces using two different routes. This can be done by binding the routes to an interface.
  • Page 116: Biss-Ca

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Appendix F. BISS-CA F.1. Overview BISS-CA (EBU Tech 3292-s1) is a conditional access system based on open cryptographic standards. It uses a com- bination of symmetric and asymmetric ciphers to protect the transmitted content and entitle or revoke, in real-time, any targeted receivers in an interoperable manner.
  • Page 117: Key

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 • Using the SK key, it can descramble the ECM and recover the SW. • Using the SW, it can descramble the TS stream. F.2. Key The public key is derived from the private key. They are RSA-2048 bits key pair. They should be stored according to the PKCS #8 syntax standard.
  • Page 118: Decoder Configuration

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Command line sample on a Debian system: openssl genpkey -algorithm RSA -out private_key.pem -pkeyopt rsa_keygen_bits:2048 openssl rsa -in private_key.pem -pubout -out public_key.pub F.3. Decoder configuration Warning Use GWT web GUI only ! (http://X.X.X.X/gwt) If you use the flash GUI, you may have to reset all the configuration.
  • Page 119: Encoder Configuration

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Service Figure F.3. Service To activate BISS-CA descrambling, go to service, set descrambling mode to BISS and biss mode to BISS-CA. All the currently registered private keys will be tested when trying to descramble the incoming TS stream.
  • Page 120 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Figure F.4. System Go to system/assets tab. Click 'Add asset' button to upload the csv file containing the IRD's public keys. Only CSV files are supported. Each public key must be inserted in a double quote and separated with a semicolon.
  • Page 121 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Figure F.5. Channel Once done, on the channel tab, go to Global setting/BISS and select CA mode. Settings: • Entitlement Session ID: ID used to identify a content protection session that is using a certain set of keys.
  • Page 122: Use Cases

    In this use case we will describe how to encode a 4k stream split into 4 HD SDI to a MPTS of 4 programs. G.1.1. Overview 2 CM5000 with 2 channels and remuxer functionality encode 2 HD SDI channels each. Channels 1 and 2 of encoder 1 will produce 2 SPTS (program number 101 and 102 respectively). These programs will be remuxed by encoder 1 remuxer in a MPTS of 101 and 102.
  • Page 123: Configuration

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 • ASI out 2 to encoder 1 ASI in. • ASI out 1 to encoder 2 SYNC in. • SDI3 to encoder 2 channel 1 SDI in. • SDI4 to encoder 2 channel 2 SDI in.
  • Page 124 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Enable Input TS 1 as Internal Channel1. In the more section configure a delay of 20ms. Enable Input TS 2 as ASI ASI input. In the more section configure a delay of 20ms. Enable Input TS 3 as ASI SYNC input. In the more section let the delay at 0ms.
  • Page 125: 4K And Modulator

    L-band/IF-band. G.2.1. Overview 4 CM5000 with remuxer functionality encode 1 HD SDI channel each. One of the encoder must have a modulator. Encoder 1 will produce 1 SPTS from HD SDI 1 (program number 101) Encoder 2 will produce 1 SPTS from HD SDI 2 (program number 201). The encoder 2 remuxer aggregates 101 and 201 in a MPTS.
  • Page 126: Configuration

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Wiring • SDI1 to encoder 1 channel 1 SDI in. • encoder 1 ASI out to encoder 2 SYNC in. • SDI2 to encoder 2 channel 1 SDI in. • encoder 2 ASI out to encoder 3 SYNC in.
  • Page 127 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Enable Input TS 1 as Internal Channel1. In the more section let the delay at 40ms. Enable Input TS 2 as ASI SYNC input. In the more section let the delay at 0ms. Configure the output bitrate with at least the sum of the program 101,201 and 301 Encoder 4 channel and modulator Don't activate the channel ASI output.
  • Page 128 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Start all channels, remuxers, and unmute the modulator. www.ateme.com Page 128...
  • Page 129: Colorimetry

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Appendix H. Colorimetry H.1. Colorimetry Colorimetry signaling detail per preset. Table H.1. SDR Master- Alternative Content light Matrix co- Transfer char- ing display Preset Color primaries transfer char- level infor- efficients acteristics color vol- acteritics SEI...
  • Page 130: Appendix

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Appendix I. Appendix I.1. Product's specification Table I.1. Specification - Identification Product Name CM5000 Table I.2. Specification - Video Input Function Values Requires Input number 1 or 2 SDI inputs - 3G Level A or Level B-DL 1080p 23.97fps / 24 fps / 25fps /...
  • Page 131: Specification - Audio Input

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.3. Specification - Audio Input Function Values Requires SDI embedded (up to 16 per SDI input) Source AES (8 AES pairs per AES board) AES board Analog (4 analog pairs per analog board) Analog board Input level up to 24 dBu Left-Right gain difference <...
  • Page 132: Specification - Data Input

    Teletext - OP47 Teletext/VPS - SMPTE 2031M VANC - SMPTE 2038 SCTE104 - SMPTE 2010 Table I.5. Specification - Black Burst-3Level and ASI Synchronization Black Burst/3Level and ASI Synchronization are not supported on CM5000 Table I.6. Specification - Filter Function Values Requires...
  • Page 133: Specification - Video Processing

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.7. Specification - Video Processing Function Values Requires Main (4:2:0) 8-bit HEVC License (7) Main 10 (4:2:0 10-bit) HEVC & 10b Licenses (7) Main 12 (4:2:0 12-bit) HEVC & 12b Licenses (7) Profil HEVC HEVC &...
  • Page 134: Specification - Pip Processing

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.8. Specification - PIP Processing Function Values Requires Baseline, Main, High 4:2:0 8 bits PIP & MPEG4 Licenses Profil H.264 High 4:2:2 8 bits PIP & MPEG4 & 422 Licenses Profil AVC-I High 10 , High 4:2:2 Intra 8 bits PIP &...
  • Page 135: Specification - Audio Processing

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.9. Specification - Audio Processing Function Values Requires Number Up to 36 per video service Audio Number License of tracks MPEG1-LII [32-384kbs] Default codec MPEG2-AAC-LC [16-512kbs] AAC License MPEG4-AAC-LC [16-512kbs] AAC License MPEG4-AAC-HE [16-96kbs]...
  • Page 136 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.11. Specification - Remuxer Function Values Requires 2 External ASI Inputs TS Remux (6) Input 2 Internal Inputs: Channel 1 Main or Channel 1 PIP TS Remux (6) Table I.12. Specification - 1+1 Redundancy...
  • Page 137 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.14. Specification - Output Function Values Requires 1 MGT interface 2 Stream interfaces 4 Outputs (2 per channel if dual) - except modulator option 1 SDI loopback (per channel) - except modulator option Backup stream...
  • Page 138: Specification - L-Band Or If Modulator

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.15. Specification - L-Band or IF Modulator Function Values Requires DVB-S QPSK Constellation QPSK License FEC 1/2, 2/3, 3/4, 5/6, 7/8 DVB-S (EN 300 421) Roll-off 0.05, 0.10, 0.15, 0.20, 0.25, 0.35 Bitrate from 3 Mbps to 72 Mbps...
  • Page 139 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 DVB-S2x FEC 64APSK: 11/15, 7/9, 4/5, 5/6 (normal frame only) 64APSK License DVB-S2x FEC 64APSK-L: 32/45 (normal frame only) 64APSK License Roll-off 0.05, 0.10, 0.15, 0.20, 0.25, 0.35 Short Frames, Long Frames Pilot Mode On/Off...
  • Page 140: Specification - Configuration And Management Interfaces

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 RF Carrier ID RF Carrier ID descriptor support Power On state Muted / Modulator state on power on restored ASI Output Second ASI Output available to broadcast the output stream L-Band main output SMA 50 Ω...
  • Page 141: Specification - System

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.17. Specification - System Function Values Requires Manual time update GMT offset Time NTP (high precision option) Individual trap support SNMP trap support Alarms GPO action on alarm Alarm message time filtering Password SNMP R & RW, WebGui...
  • Page 142: Aac

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.18. Specification - Licenses License Name Max Value HEVC video encoding HEVC 10-bit HEVC 12-bit HEVC 4:2:2 HEVC maximum bitrate 20 to 120 MPEG-4 AVC 10-bit 1 to 2 MPEG-4 AVC High 4:2:2 profile...
  • Page 143 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 DVB-DSNG 8PSK Modulation DVB-DSNG 16QAM Modulation DVB-S2 QPSK Modulation DVB-S2 8PSK Modulation DVB-S2 16APSK Modulation DVB-S2 32APSK Modulation DVB-S2X DVB-S2X 64APSK Modulation www.ateme.com Page 143...
  • Page 144: Specification - Physical

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Table I.19. Specification - Physical 19'' 1-RU Dimensions 482x44x519 mm /19''x1.73''x 20,4'' min: 6.4 kg/14.1 lbs Weight max: 7.3 kg/17 lbs Table I.20. Specification - Environmental and Power Cooling Cooling air flow from front to back Operating Temperature 5 °C to 40 °C / +41 °F +104 °F...
  • Page 145: Notes

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 I.1.1. Notes (1) SCTE-104 messages must respect the following restrictions when they are used to generate SCTE-35: - They should use the multiple_operation_message() format. All single_operation_message() are discarded. - They should contain only one operation per multiple_operation_message(). If more than one operation is present in the same multiple_operation_message(), the following ones are discarded.
  • Page 146: Warranty

    To obtain warranty service, call ATEME Technical Support. You will be asked to provide your ATEME product's Serial Number, and you may be asked to furnish proof of purchase to confirm that the CM5000 is still under warranty. All CM5000 returned to ATEME must be securely packaged in their original box and shipped with postage prepaid.
  • Page 147: Normative Reference

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 I.3. Normative Reference Table I.22. Normative reference Subject Reference Ancillary AFDBarData SMPTE 2016M-1/3 Ancillary ATC SMPTE 12M-2 Ancillary Audio HD SMPTE 299M Ancillary Audio SD SMPTE 272M Ancillary cc608 SMPTE 334-2 Ancillary cc708 SMPTE 334-1...
  • Page 148: Glossary

    CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 I.4. Glossary Table I.23. Glossary 3:2 pull- Process of converting 24 frame/s material to 29.97 frame/s. down Sampling method. In 420 sampling, chrominance components have half the horizontal and vertical 422/420 resolution of luminance component. In 422 sampling, chrominance components have half the hori-...
  • Page 149 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 Management information base stems from the OSI/ISO Network management model and is a type of database used to manage the devices in a communications network. It comprises a collection of ob- jects in a (virtual) database used to manage entities (such as routers and switches) in a network.
  • Page 150 CM5000 User Manual UM-CM5000-FW3.5.2.0-REV0.0 2019-07-08 SNMP, a communication protocol between management stations (consoles, for example) and man- aged objects, (such as routers, gateways, and switches) makes use of MIBs. Components controlled by the management console need a so-called SNMP agent -- a software module that can communi- SNMP cate with the SNMP manager.
  • Page 151: Support And Resources

    CM5000 to work properly, contact us via the provided link. ATEME Technical Support - support@ateme.com Before contacting us, make sure that you have a physical access to your CM5000 and that you have the following information on hand: • Your CM5000's Serial Number •...

Table of Contents

Save PDF