1.3. Copyrights Notice The ATEME Kyrion(R) is not designed or intended to violate any other entity's copyright or other IP (In- tellectual Property) rights. Each ATEME Kyrion(R) user may only use their ATEME Kyrion(R) in con- junction with materials legally owned or licensed by such user, and only to the extent that such ownership or license rights permit such use.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 In no event shall ATEME be liable for any indirect, special, consequential or incidental damages, including, but not limited to, lost profits or loss or damage to data arising from the use of these materials, even if advised in advance of the possibility of such damages.
2.1. Package Content Before continuing, please check the content of the product package. This product package should contain the following items: • One (1) Kyrion(R) CM5000, • One (1) Power Cord, • One (1) CD ROM, • This User's Manual.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.2. Front View Next picture describes the front interface of the Kyrion(R) CM5000. Figure 2.1. Front View Interface Table 2.1. Front View Interface Front Panel Air Intakes Front Panel Interfaces FP are described in Section 4.2, “ Front Panel ”...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.3. Rear View Next picture describes the generic rear interfaces of Kyrion(R) Encoders. Depending on your exact model and the options purchased, the extended slots may contain additional connectors which will be described in the next paragraphs.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.4. Power Switch Next figure describes the location of the Power switch of the Kyrion(R) CM5000. Figure 2.3. Power Switch Table 2.3. Power Switch Use this switch to turn ON the unit. Switch it Power Switch back to the original position to turn OFF the unit.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.5. I/O Base Interfaces Next figure describes the I/O Base interfaces of the Kyrion(R) CM5000. Figure 2.4. I/O Base Interface Table 2.4. I/O Base Interface Connect the provided cable to this inlet. AC Inlet (~AC) The Kyrion(R) auto detects AC voltage.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.6. Extended Interfaces Depending of the hardware options that you purchased, some of the next interfaces may be accessible on I/O Extended Interfaces ([X], [VA], [VB]). www.ateme.com Page 14...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.6.1. Extended L-Band Modulator Interfaces Next figure describes the Extended L-Band Modulator interfaces of the Kyrion(R) CM5000. Figure 2.5. Extended L-Band Modulator Interfaces Table 2.5. Extended L-Band Modulator Interfaces XLB1 Encoder SDI IN Use this BNC connector to input the SDI video signal into the Encoder.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.6.2. Extended IF Modulator Interfaces Next figure describes the Extended IF Modulator interfaces of the Kyrion(R) CM5000. Figure 2.6. Extended IF Modulator Interfaces Table 2.6. Extended IF Modulator Interfaces Encoder XIF1 Use this BNC connector to input the SDI video signal into the Encoder.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.6.4. Extended Analog Audio Interfaces Next figure describes the Analog Audio extended interface of the Kyrion(R) CM5000. Figure 2.8. Extended Analog Audio Interfaces Table 2.8. Extended Analog Audio Interfaces Analog Audio Input Use this DB25 connector to input up to 4 analog audio pairs.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.7. Serial Number Serial Number and Production Code Markings are located in the rear side [SN]. Figure 2.9. Serial Number and Production Code Markings www.ateme.com Page 20...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 2.8. Ventilation Air ventilation prevents abnormal temperature rises inside the unit. Next figures show cool air intakes and warm air outputs. Figure 2.10. Cool air intakes on the front panel Figure 2.11. Warm air outputs on the rear panel Place the Kyrion(R) in a well-ventilated space, and allow ideally up to 10cm of free space on all sides of the Kyrion(R) so increasing air circulation and cooling.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 3. Installation 3.1. Hardware setup Step 1: Unpack and install the Kyrion(R) Unpack your Kyrion(R) unit and install it. • For Stand Alone installation, place the unit on a stable surface. It requires clearance above and on each side to allow cooling.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 • After a few seconds, a BOOTING message should appear on the LCD. • The front panel selection menu appears when the unit is up and running. 3.2. Quick start Step 1 : Configure management IP address Use the front panel to configure the MGT IP address of the encoder: [Kyrion IP address] (System ->...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 4. User's Interfaces 4.1. Three configuration tools There are 3 different ways to configure your Kyrion(R): • Front Panel access (see Section 4.2, “ Front Panel ”), • Web-based interface (see Section 4.3, “ Web GUI ”), •...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Table 4.1. Status LED Off : Encoder idle Solid Green : Valid input signal Solid Orange : No input signal Off : Encoder idle Solid Green : Valid output signal Solid Orange : Invalid output signal...
Page 26
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Uptime Channel Monitor SD Aspect Ratio Load From Slot Preset Channel 1 Save To Slot Table 4.3, “Front Panel Modulator Menu - Service Modulator” Service Name Table 4.4, “Front Pan- Main el Menu - Service Main”...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Table 4.3. Front Panel Menu - Service Modulator Enabled Transmit Mode Output Power (dBm) BUC's LOF (MHz) Frequency (MHz) Symbol Rate (MBd) Service Modulator Standard Type Roll-off Frame Type Pilot mode Spectral Inversion 10 MHz Clock Ref Table 4.4.
Page 28
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Enabled Format MPEG Layer 2 Audio 1 Dolby Digital SMPTE 302M Input Processing Enabled Input Processing Format Teletext Data 1 SCTE-35 DVB Subtitles SMPTE-2038 www.ateme.com Page 28...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 4.3. Web GUI With the web-based interface you have access to all the parameters. 4.3.1. Access setup Ethernet connection Connect the Kyrion(R) MGT interface B2 to an Ethernet connection. You can either: • use a cross-over Ethernet cable to connect the devices directly to the controlling computer, •...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Login protection and the associated password can be configured in the System tab of the Web interface (see Section 4.3.5, “ System Tab ”). Figure 4.2. Log into the Web Server Note The login dialog box will be displayed in your OS language. It may be different that the above figure.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Figure 4.3. Web Based Interface 4.3.3. Status Tab This Tab is used to monitor the status of the encoder channels. Figure 4.4. WEB Based Interface - Status Tab • [GS1]: Outputs state summary. • [GS2]: Channel state summary.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Figure 4.5. WEB Based Interface - Channel Tab • [GC1]: Button used to load a preset into the web GUI editor. The preset can be loaded from a file, from slots stored on the Kyrion(R) or from a preset using factory settings. This action does not disrupt nor reconfigure the encoder.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 4.3.5. System Tab This tab allows you to configure the system settings, monitor and manage the equipment. Figure 4.6. WEB Based Interface - System Tab Simple setting edition Figure 4.7. Simple setting edition To edit a simple setting, you can: •...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 To edit one or multiple settings of a line in a table: • Click on the setting you want to edit. The buttons [GS4] and [GS5] appear. They apply for the whole line. • Update the values on the line.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 5. Settings This chapter lists all the parameters that can be set through the GUI Interface. Some are not accessible depending on your product or the licenses that you purchased. See the product specification in annexes to check capability of your product.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 PMT PCR PID (number) PAT TS ID (number) PAT period (number) PMT period (number) CAT period (number) Enabled non PSI tables DVB/ISDB/SBTVD compliance Those settings are available when 'TS conformance' is one of DVB, ISDB or SBTVD (Full/one-seg).
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 9/10 Use external reference clock 0.20 Roll-off 0.25 0.35 Normal Frame type Short Pilot mode Spectral inversion 5.1.5. Output IP Table 5.8. Output IP Parameter Value Note Enable Main interface Stream 1 Stream 2 Main IP...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 MPEG-2 Video PID (number) Black Pattern Emulation mode Freeze Custom Mute Emulation moving pattern Resize None Denoise Medium High IVTC Logo name (string) Logo X (number) Logo Y (number) GOP Size (number) GOP B Frames...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Deblocking strength (number) Flat Scaling matrixes Default Allow CABAC Allow hierarchical B frames Allow HRD information Enable AFD bar data SEI Enable picture timing SEI Table 5.11. MPEG-4 AVC-I Parameter Value Note High 10 intra...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Emulation forced Delay (real number) Gain (real number) Table 5.14. MPEG Layer2 Parameter Value Note Copyright bit Original bit Table 5.15. AAC Parameter Value Note TNS allowed MS allowed Table 5.16. Dolby Digital Parameter Value...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Normal 16:9 Normal 2.21:1 Normal HD Hearing Impaired Hearing Impaired 4:3 Hearing Impaired 16:9 Hearing Impaired 2.21:1 Hearing Impaired HD Language code Composition ID (number) Ancillary ID (number) 5.2. System Settings 5.2.1. System - Miscellaneous Table 5.23.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 6. Specific Operations 6.1. Installing License On the web GUI, go to the System tab and click License. The upper section is used to update the license settings. To do so, click the Update button. A popup should appear asking for a license file. Click on the Browse button to point to it and click Ok to proceed with the update, or Cancel to abort.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Note You can check that the upgrade process did well by checking that the displayed Current Version number is the one expected. Note Update package are specific files provided by ATEME support. They should bear the exten- sion ".pkg".
Page 50
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 • Step 2: Watch for a Maintenance message displayed on FP5 after a few seconds. • Step 3: Quickly press the green ticker (FP7 see Section 4.2, “ Front Panel ”) to enter the Maintenance menu.
Teletext/VPS (SMPTE 2031M) SCTE104 (SMPTE 2010) Teletext Page properties configuration Table A.9. Specification - Black Burst-3Level and ASI Synchronization Black Burst/3Level and ASI Synchronization are not supported on CM5000 Table A.10. Specification - Filter Function Values Requires Resize 4/5 3/4 2/3 1/2...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Table A.16. Specification - L-Band or IF Modulator Function Values Requires Constellation QPSK DVB-S QPSK FEC QPSK 1/2, 2/3, 3/4, 5/6, 7/8 Modula- DVB-S (EN 300 421) tion License Roll-off 0.35 Bitrate from 3 Mbps to 40 Mbps...
Page 58
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 > 34 dB Shoulder rejection Less than -45 dB at f/fn = 2 H2 rejection Less than -45 Db @10Hz less than -55 dBc/Hz @100Hz less than -70 dBc/Hz @1KHz less than -80 dBc/Hz Phase Noise...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Table A.17. Specification - System Function Values Requires Time update Time NTP server support (high precision option) GMT offset support Individual trap support Alarms SNMP trap support Alarm message time filtering Password SNMP R and RW, WebGui...
Page 60
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 Feature Licenses Some features need a license to be activated: • AAC LC/HE support • AAC HEv2 support • Pro-MPEG FEC support • HD video support • MPEG-4 AVC High 4:2:2 profile support • Max audio channel number support •...
Any loss, corruption or destruction of data while using an ATEME Kyrion(R) is the sole responsibility of the user, and under no circumstances will ATEME be held liable for the recovery or restoration of this data.
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 A.4. Glossary Table A.19. Glossary 3:2 pull- Process of converting 24 frame/s material to 29.97 frame/s. down Sampling method. In 420 sampling, chrominance components have half the horizontal and 422/420 vertical resolution of luminance component. In 422 sampling, chrominance components...
CM5000 users' manual UM-CM5000-FW1.1-REV1.0 2012-10-30 A.5. Support and Ressources Contact Technical Support Before You Contact Technical Support: • Read the manuals. • Try to isolate the problem or to reproduce it many times. • Make sure that all of the cables are correctly and firmly attached.
Need help?
Do you have a question about the CM5000 and is the answer not in the manual?
Questions and answers
Shortcu to Adjust brightness from the front pannel of the CM5000