SL24.D 1 - Product characteristics Control unit for governing sliding gear motors at 24 Vdc with a maximum power of 80 W, equipped with an encoder interface to detect obstacles and control the speed, and an integrated 433 MHz receiver. The control panel: - can customize the slow-down distance and speed for both opening and closing - has an obstacle detection system...
SL24.D 3 - Description of the terminal blocks 15 A F1 (ATO) PROGRAM. MENU' 15 A F1 (ATO) PROGRAM. MENU' F2 (5X20) F2 (5X20) F3.15 A F3.15 A ENCA ENCB ENCA ENCB 51 52 61 62 51 52 61 62 21 22 12 14 1 0 10 11 99 61 62...
Page 5
- 230 Vac 15 A F1 (ATO) - 120 Vac PROG F2 (5X20) F3.15 A SL24.D F1 (ATO) F2 (5X20) 51 52 61 62 F3.15 A 21 22 12 14 1 0 10 11 99 61 62 31 99 32 15 A F1 (ATO) ENCA...
Page 6
SL24.D 3.1 - Description of output function Photocell - PH (N.C.): Operating according to the setting for parameter P06: Accessories power supply: P06 = 1 Photocell: 24 Vdc output - with the gate stopped, does not allow the gate to open Functions according to the P08 parameter setting.
SL24.D 4 - Connecting accessories 4.1 - Key switch and control devices EDS1 N.C. N.C. N.O. N.O. 99 61 62 Step-by-step control Pedestrian control 4.2 - Photocells and photocells when closing Normally closed contact (when the photocells are not engaged the 62 and 63 LEDs must be on), if not used then jumper 62 to 99 and 63 to 99, you must observe the polarity of the power supply for the photocells: 51 52 61 62 (FSW)
Page 9
SL24.D 5.2 - Using the display Self-calibration: If the gate travel parameter is changed, there is no need for the installer Button Description to run new calibrations, however, when changing the travel parameters, Button to turn on the display, to access the menu and to the control panel needs to learn the current curve again, thus disabling confirm the parameter value change.
Page 10
SL24.D Output 14 type of open gate warning loght Safety input n. 62 (SCA) Photocell on closing (PHC) Gate closed: not active - with the gate stopped, allows the gate to open Gate not closed: active fixed - during the opening does not intervene - with the gate open, does not allow it to close Gate closed: not active and when released will reload the pause time...
Page 11
SL24.D Direction (OFF) Factory reset Left-hand actuator (the gate, seen from the Display Button Description side of the gate where the actuator is located opens to the left) Waiting to press OK for 5 s to load factory oooo Right-hand actuator (the gate, seen from settings the side of the gate where the actuator is Note:...