Appendix A: Annual Inspection Checklist - Avanti Runner 2000 Original Instructions Manual

Fall protection system
Table of Contents

Advertisement

Appendix A: Annual inspection checklist

Runner 2000/2002 or Eagle
Type of AVANTI Runner:
Standards:
EN353-1 / RfU11.073 / AS/NZS1891.3
Tower (WEA-No.):
Date of inspection:
1
Ladder system
1.1
Rungs
Are dents less than 10 mm in diameter or 1 mm deep?
Are the rung ends fixed tight to the stiles?
Are the rungs free of cracks?
1.2
Stiles
Are dents less than 20 mm in diameter or 1 mm deep?
Are the stile ends free of dents?
Are the stiles free of cracks?
1.3
Flange connection kits
Is the distance between the rungs of consecutive ladder sections at tower flange between 255 and 300 mm?
1.4
Ladder ends
Are the AVANTI rubber feet or end caps mounted?
1.5
General
Is the ladder system free of dirt (oil, corrosion, paint, etc.)?
2
Safety rail system
2.1
Safety rail sections
Are the safety rail sections mounted on the front side?
Is the guide seat of each safety rail section placed on the left side?
Are the ends of each safety rail section free of sharp edges?
2.2
Rung fitting
Is there a rung fitting on the first (lowest) rung of each ladder section?
Is there a rung fitting on the last (highest) rung of each ladder section?
Is there a rung fitting on at least every third rung of each ladder section?
Is each rung fitting free of damages?
2.3
Fish-joints
Is each fish-joint mounted with 4 hammerhead screws?
Are all the indicator marks of the hammerhead screws and the self-locking nuts at an angle of 70º?
2.4
General
Is the safety rail system free of dirt (oil, corrosion, paint, etc.)?
Is the safety rail system free of damages?
3
Others
3.1
Resting platforms
Are the resting platforms in place and fixed properly?
3.2
Screws
Are all the screws in place and torqued properly?
3.3
Labels and markings
Are all the labels and markings legible?
4
Runner system
4.1
-
Is the runner approved for use?
5
Final assessment
5.1
-
Is the FPS approved for use?
This inspection shall be carried out before the first use and at least every 12 months by AVANTI or by a
certified technician. This checklist and the Inspection log sheet shall be filled in and filed for future reference.
User´s name:
DS
Phone:
Name of inspector:
Date of next inspection:
OK
NOK
COMMENTS
OK
NOK
COMMENTS
OK
NOK
COMMENTS
OK
NOK
COMMENTS
OK
NOK
COMMENTS
Inspector´s Signature:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Runner 2002Eagleds runner

Table of Contents