NO OPERATION OF MD
When no sound output in the CD function, you can not listen to music reading data from a CD disc if
the pickup module in MD doesn't work. This step is for checking the LASER FOCUSING ACTUATOR.
4-5. LASER FOCUSING ACTUATOR
4-5-1. Solution
Please check and replace IC400, IC401 on MAIN board.
4-5-2. How to troubleshoot (Countermeasure)
The focusing actuator makes the laser beam keep a regular interval with the surface of a CD disc.
1) Check the FOD signal from Pin13 of IC401.
If no signal, check 3.3 V(RF) and X400.
2) Check F- & F+ from IC400 to CN400 for driving the focusing actuator.
If no signal, check +1.8 V and +5 V for IC408.
3) Check if the FFC cable is solidly connected between CN400 and MD.
4) Check the MD.
If the pickup module has any trouble, it can not move the laser beam on the top or bottom side.
Please check the function after changing another MD.
4-5-3. Service hint (Any picture/ Remark)
< Waveform of F±
for driving FOCUSING actuator >
ONE POINT REPAIR GUIDE
3-10
< Signal check point >