Scheme 4a The example of triggering the signaling device and optical indication when the system is armed/
disarmed.
Scheme 4b Example of triggering the signaling device with separation of optical and acoustic signals
Scheme 4c Connection of the signaling device with two wires
Caution: When separating the optical and acoustic indication
(because of the use of the "A" terminal), some functions
adjustable via the switches are not available.
„+" shorted to ground with „S" → no
alarm
(no optical-acoustic indication)
„+" opened from ground with „S" →
alarm
(optical-acoustic indication)
ARM/DISARM
LIGHT
(DIP4)
Arming – indicated with three short
optical flashes
Disarming – 1 longer optical signal
„+"shorted to ground with „S"
→ no alarm
(no acoustic indication)
„+"opened from ground with „S"
→ alarm (acoustic indication)
„+"shorted to ground with „A" →
no alarm (no optical indication)
„+"opened from ground with „A"
→ alarm
(optical indication)
Connecting the signaling device
using two power cables and the
activation
of
optical-acoustic
indication by supplying power.
Caution!
The first powering activates the
device.
The
performed only once.
Each subsequent powering
triggers optical-acoustic
indication.