The exclusive distributor of AMC products SR 136 CODE In accordance with the External optical and acoustic signaling device MANUAL EN (DYNAMIC transducer 110dB; LED; metal SR136 EN 50131-4 standard enclosure; optional connection of the 12V/2,2Ah battery) Edition: 2 from 03.07.2014 Supersedes: 1 from 10.02.2014...
2. Installation The signaling device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for Intrusion Detection Systems. The mounting location of the signaling device should be inaccessible in order to minimize the risk of tampering.
Page 3
Fig. 1c Tamper indicating detachment from the wall Caution! The proper indication of detachment from the wall requires screwing the additional screw to the mounting base, which will result in closing the tamper switch once the signaling device is mounted on the wall.
Page 4
3. Configuration of the signaling device The configuration of the signaling device is using two groups of switches: „MODE” and „FUNCTIONS”, which are placed on the Printed Circuit Board (see Fig. 2). Any change in configuration of the signaling device (change in the switch position) is confirmed with a short beep.
Page 5
The "FUNCTIONS" switch Eight-position ON/OFF switch "FUNCTIONS" activates additional function that can be performed by the signaling device. Table 2.The "FUNCTIONS" switch The DIP switch number Function DIP1 MEMORY SOUND The signaling device implements the following function: if an alarm Acoustic alarm memory has occurred (is saved) the device will generate several beeps at the moment of disarmament.
Page 6
Scheme 4a The example of triggering the signaling device and optical indication when the system is armed/ disarmed. „+” shorted to ground with „S” → no alarm (no optical-acoustic indication) „+” opened from ground with „S” → alarm (optical-acoustic indication) ARM/DISARM LIGHT function...
The connection of the signaling device to the control panel. The OUT3 and OUT5 control panel outputs enable the +12V power supply of the signaling device. The OUT3 output is programmed as the power supply output. The "S" control input, which is shorted to ground, is used to control the signaling device. By default, when the alarm is inactive (no alarm), the +12 V is supplied at the "S"...
Page 8
In accordance with the standards: CEI EN 50131-4:2010-08 RoHS Grade 2 Class 4 Additional information The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to operate the equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual.
11. The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to operate the equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual. The exclusive distributor of AMC products: Pulsar K. Bogusz Sp.j. Siedlec 150, 32-744 Łapczyca, Poland Phone (+48) 14-610-19-40, Fax (+48) 14-610-19-50 E-mail: biuro@pulsar.pl, sales@pulsar.pl...