Association
This sensor has two Association groups with only one node for each group. Group one is a lifeline
group who will receive unsolicited messages relating to case tamper notifications, battery level
notifications, Wake-Up notifications, and Device Reset Notifications. Group two is intended to be used
with multi-channel association for a controller to subscribe to contact switch open/close notifications
sent encapsulated from each of the eight endpoints one for each contact switch. Each endpoint must
be enabled by putting the controller's node ID into the device's Association Group 2 with either an
Association Set encapsulated with Multi-Channel Encapsulation OR a Multi-Channel Association Set
encapsulated with Multi-Channel Encapsulation.
Example Multi Channel Association Set Command:
Group Identifier
Node ID
Marker
vg
Multi-Channel Node ID
End Point
Bit Address
Configuration
The sensor has seven supported configuration parameters.
Parameter
Description
Number
Number of seconds between periodic
1
battery reports. (Heartbeats)
One-Time Wakeup Notification. (In ad-
2
dition to normal Wakeup Notification)
Number of Application Level Retries
after a failed transmission defined as
3
either not ACKed or Supervision Report
not returned when encapsulated.
The minimum number of seconds to
4
sleep between application level retries.
Application Retry Multiplier.
The number of seconds between a
5
current application retry is the count
of retries multiplied by this number in
seconds + a small random delay.
6
2
Blank/Nothing Entered
0x00
1 (Press plus button to make the variant group fields appear.)
01 (Controller's Node ID)
0x00
Not Selected
Number
Default
of Bytes
4200
2
(0x1068)
0
2
(Not in use).
1
5
1
6
1
5
Min
Max
4200
255 (0xFF)
(0x1068)
1 (must be
divisible by
sleep step
3600
time of
(0x0E10)
configuration
parameter 7)
1
15
60
1
(0x3C)
1
5