Standard Horizon HX600S Alignment Manual
Standard Horizon HX600S Alignment Manual

Standard Horizon HX600S Alignment Manual

Hide thumbs Also See for HX600S:

Advertisement

Quick Links

The HX600S has been carefully aligned at the factory for the specified performance
across the land mobile band.
Realignment should therefore not be necessary except in the event of a component
failure.
All component replacement and service should be performed only by an authorized
STANDARD HORIZON representative, or the warranty policy may be voided.
The following procedures cover the sometimes critical and tedious adjustments that are
not normally required once the transceiver has left the factory. However, if damage occurs
and some parts are replaced, realignment may be required. If a sudden problem occurs
during normal operation, it is likely due to component failure; realignment should not be
done until after the faulty component has been replaced.
We recommend that servicing be performed only by authorized STANDARD HORIZON
service technicians who are experienced with the circuitry and fully equipped for repair and
alignment. Therefore, if a fault is suspected, contact the dealer from whom the transceiver
was purchased for instructions regarding repair. Authorized STANDARD HORIZON service
technicians realign all circuits and make complete performance checks to ensure
compliance with factory specifications after replacing any faulty components. Those who do
undertake any of the following alignments are cautioned to proceed at their own risk.
Problems caused by unauthorized attempts at realignment are not covered by the
warranty policy. Also, STANDARD HORIZON must reserve the right to change circuits and
alignment procedures in the interest of improved performance, without notifying owners.
Under no circumstances should any alignment be attempted unless the normal function
and operation of the transceiver are clearly understood, the cause of the malfunction has
been clearly pinpointed and any faulty components replaced, and the need for realignment
determined to be absolutely necessary. The following test equipment (and thorough
familiarity with its correct use) is necessary for complete realignment. Correction of
problems caused by misalignment resulting from use of improper test equipment is not
covered under the warranty policy. While most steps do not require all of the equipment
listed, the interactions of some adjustments may require that more complex adjustments be
performed afterwards. Do not attempt to perform only a single step unless it is clearly
isolated electrically from all other steps. Have all test equipment ready before beginning,
and follow all of the steps in a section in the order presented.

Required Test Equipment

Radio Tester with calibrated output level at 200 MHz
ο
In-line Wattmeter with 5% accuracy at 200 MHz
ο
50 Ω, 10 W RF Dummy Load
ο
Regulated DC Power Supply adjustable from 3 to 15 VDC, 2A
ο
Frequency Counter: ±0.2 ppm accuracy at 200 MHz
ο
AF Signal Generator
ο
AC Voltmeter
ο
DC Voltmeter: high impedance
ο
VHF Sampling Coupler
ο
Alignment Preparation & Precautions
A 50 Ω RF load and in-line wattmeter must be connected to the main antenna jack in all
procedures that call for transmission, except where specified otherwise. Correct alignment
is not possible with an antenna. After completing one step, read the next step to see if the
same test equipment is required. If not, remove the test equipment (except dummy load
and wattmeter, if connected) before proceeding.
Correct alignment requires that the ambient temperature be the same as that of the
transceiver and test equipment, and that this temperature be held constant between 20 ~
HX600S Alignment
1/5
FCC ID: K6630193X20
IC ID: 511B-30193X20
Alignment
Vertex Standard Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HX600S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Standard Horizon HX600S

  • Page 1 FCC ID: K6630193X20 IC ID: 511B-30193X20 Alignment HX600S Alignment The HX600S has been carefully aligned at the factory for the specified performance across the land mobile band. Realignment should therefore not be necessary except in the event of a component failure.
  • Page 2 FCC ID: K6630193X20 IC ID: 511B-30193X20 Alignment 30 °C (68 ~ 86 °F). When the transceiver is brought into the shop from hot or cold air, it should be allowed some time to come to room temperature before alignment. Whenever possible, alignments should be made with oscillator shields and circuit boards firmly affixed in place.
  • Page 3 FCC ID: K6630193X20 IC ID: 511B-30193X20 Alignment Set the transceiver to CH16 (156.800 MHz) with “high” power mode, and then turn the transceiver off. Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver on to enter the alignment mode.
  • Page 4 FCC ID: K6630193X20 IC ID: 511B-30193X20 Alignment Press the [MEM] key to enable adjustment of this Alignment Mode. Press the [▼] or [▲] key to adjust the deviation level. Press the [MEM] key to exit this Alignment Mode. Press the [▼] or [▲] key to select the display to [FSK 0 xx], then confirm the deviation meter reading.
  • Page 5 FCC ID: K6630193X20 IC ID: 511B-30193X20 Alignment Squelch Tight Adjustment Adjust the Radio Tester output level +2 dBµ (with a standard AM modulation: 30 % AM modulation @ 1 kHz) at 1.100 MHz. Press the [▼] or [▲] key to select the display to [AM TI xxx]. Press the [MEM] key to read the Squelch Tight data.

Table of Contents