Maintenance

WARNING
Remove batteries before cleaning.
• Always clean the imager head and cable
after use with mild soap or mild deter-
gent.
• Gently clean the display screen with a
clean dry cloth. Avoid rubbing too hard.
• Use only alcohol swabs to clean the
cable connections.
• Wipe the hand held display unit down
with a clean, dry cloth.

Reset Function

If the unit stops functioning and does not
operate, press the Reset Button (under the
left side port cover – Figure 4). The unit may re-
cover to normal operation when re started.

Accessories

WARNING
To reduce the risk of serious injury, only use
accessories specifically designed and rec‑
ommended for use with the RIDGID micro
CA‑300 Inspection Camera such as those
listed below. Other Ac ces sories suitable
for use with other tools may be hazardous
when used with the micro CA‑300 Inspec‑
tion Camera.
micro CA-300 Inspection Camera
Accessories
Catalog
No.
Description
37108
3' (90 cm) Cable Extension
37113
6' (180 cm) Cable Extension
37103
Imager Head and 90 cm Cable -
17 mm
37098
1m length 6 mm diameter imager
37123
17 mm Accessory Pack (Hook,
Magnet, Mirror)
40028
AC Adapter
40623
Headset Accessory with
Microphone
Further information on accessories speci fic to
this tool can be found in the RIDGID Catalog and
online at www.RIDGID.com or www.RIDGID.eu.
micro CA-300 Inspection Camera

Storage

The RIDGID micro CA-300 Inspection Cam era
must be stored in a dry secure area between
-4°F (-20°C) and 158°F (70°C) and humidity
between 15% and 85% RH.
Store the tool in a locked area, out of the
reach of children and people unfamiliar with
the micro CA-300 Inspection Cam era.
Remove the battery before any long period
of storage or shipping to avoid battery leak-
age.

Service and Repair

WARNING
Improper service or repair can make the
RIDGID micro CA‑300 Inspection Camera
unsafe to operate.
Service and repair of the micro CA-300 In spec-
tion Camera must be performed by a RIDGID
In dependent Authorized Service Center.
For information on your nearest RIDGID In-
depen dent Service Center or any service or
repair questions:
• Contact your local RIDGID distributor.
• Visit www.RIDGID.com or www.RIDGID.eu
to find your local RIDGID contact point.
• Contact RIDGID Technical Services De‑
partment at rtctechservices@emerson.
com, or in the U.S. and Canada call (800)
519-3456.

Disposal

Parts of the RIDGID micro CA-300 Inspection
Camera contain valuable materials and can
be recycled. There are companies that spe-
cialize in recycling that may be found locally.
Dispose of the com ponents in compliance
with all applicable regulations. Contact your
local waste management authority for more
information.
For EC Countries: Do not dispose of
elec trical equipment with house-
hold waste!
According to the European Guide-
line 2002/ 96/EC for Waste Elec-
trical and Electronic Equipment
and its imple men tation into na-
tional legislation, electrical equipment that
is no longer usable must be collected sepa-
rately and disposed of in an environmentally
correct manner.
15