Installation Guide
Wastewater pumps - S-WN series
Version 1.0 2015
End-of-life, units has to be recycled in accordance with local regulations.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S-WN Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DanPumps S-WN Series

  • Page 1 Installation Guide Wastewater pumps - S-WN series Version 1.0 2015 End-of-life, units has to be recycled in accordance with local regulations.
  • Page 2: Table Of Contents

    1. Content 2. Pump labels .................................. Page 3 3. Applications .................................. Page 3 4. Technical specification .............................. Page 4 5. Handling ..................................Page 5 6. Pump installation ................................ Page 5 7. Electrical installation ..............................Page 6 8. Operation ..................................Page 7 9.
  • Page 3: Pump Labels

    The pumps meet EU’s machine directive, see declaration of conformity at the back of this manual. DanPumps guarantees that the pumps’ airborne noise level does not exceed the noise level of 74 dbA (at normal operation).
  • Page 4: Technical Specification

    4. Technical specification The S-WN pumps are built with motor in 3-phased version for 50 or 60 Hz. Volt selection between 230/400 and 400/690 after choice. Please see motor label for accurate motor information on this pump. Motor space heater 1x230vac. 50watt up to 100watt. Always secure with extern fuse. PTC resistance has 200-250ohm at 20ºC.
  • Page 5 Pump...
  • Page 6: Handling

    5. Handling The pump must be packaged properly during transport to avoid damage to the pump or surroundings. It can be transported and/or stored in vertical or horizontal position. Always place the pump on a stable surface, so it cannot tip over during service, transport, testing and installation.
  • Page 7: Electrical Installation

    7. Eletrical Installation Work is only permitted to be carried out by qualified specialists and must to be carried out in accordance with local regulations. Before work commences, ensure that all power is switched off and cannot be switched on again accidental. This also applies to the auxiliary power circuits, e.g. anti-condense heaters. Check that supply voltage and frequency are the same as rated data.
  • Page 8 Declare under our sole responsibility that the products / Erklärt eigenverantwortlich, daß die Produkte Spildevandspumpe / Wastewater pump / Abwasserpumpe Series: S-WN series Models: S-WN1, S-WN2, S-WN3 and S-WN4 Som er omfattet af denne erklæring, er i overensstemmelse med følgende standarder / To which this declaration relates are in conformity with the following standards / Auf die sich diese Erklärung bezieht, den folgenden normativen Dokumenten entsprechen...
  • Page 9 SonFlow A/S Nordager 25 DK - 6000 Kolding www.sonflow.dk Copyright © 2013 SonFlow A/S SonFlow A/S can accept no responsibility for possible errors in catalogues, brochures and other printet materials. SonFlow A/S reserves the right at any time to change the specifications without notice.