Arena Luci LCZG1019FA-RGBW User Manual

Arena Luci LCZG1019FA-RGBW User Manual

Rgb / rgbw controller based on zigbee 3.0 protocol

Advertisement

Quick Links

LCZG1019FA-RGBW
This
instruction
manual
information about the installation and use of the
projector.
Please
instructions carefully.
The security of this device is guaranteed only with
the proper use of the following instructions,
therefore they must be kept carefully.
Never install the device in locations easily
accessible by people who ignore the existence of
this user's manual and safety instructions.
Disconnect the unit from any power supply before
attempting any operation in contact or inside the
unit, and when not in use.
It is essential that each device is correctly earthed
and that electrical installation conforms to all
relevant standards.
Prior to connect the unit to the mains supply,
check the output voltage fits the technical
requirements on the label.
Never let the power cord come into contact with
other cables.
Never touch the electrical contacts, either directly
with your fingers, or indirectly by means of sharp
or metal objects.
Make sure that cables cannot cause trip hazard.
Do not attempt to dismantle and modify the unit.
Due to the high technological level of this unit, any
Please note that as part of Arena Luci's ongoing commitment to continuous product development, specifications
are subject to change in the course of product improvement without notice. Arena Luci is not responsible for
damages resulting from improper or different use than expected.
User's manual
RGB / RGBW controller based on ZigBee 3.0 protocol
contains
important
read
and
follow
WARNINGS
service maintenance should be performed by
specialised operators. Please contact your Arena
these
Luci dealer for any operation.
Always ensure that the structure to which you are
attaching the unit is secure and is able to support
the weight of each unit.
Do not allow contact with water or any other fluids,
or metallic objects (IP 20).
Do not install the projector in areas of high
humidity. The unit is intended only for indoor
purposes.
Avoid installing the unit close to heat sources.
Allowed to be mounted directly on inflammable
surfaces.
Install the unit where it can be easily aerated.
Do not use any solvent based cleaning agents.
Use only a soft, dry anti-static cloth.
The installation of LED modules (including power
supplies) should be done according to current
technical rules and regulations. The installation
should be performed only by a qualified operator.
Avoid contact with either corrosive agents or
humidity and moisture on delicate elements:
damages from corrosion are not refunded as
component defects.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LCZG1019FA-RGBW and is the answer not in the manual?

Questions and answers

Summary of Contents for Arena Luci LCZG1019FA-RGBW

  • Page 1 Please note that as part of Arena Luci's ongoing commitment to continuous product development, specifications are subject to change in the course of product improvement without notice. Arena Luci is not responsible for damages resulting from improper or different use than expected.
  • Page 2 LCZG1019FA-RGBW Important: Read All Instructions Prior to Installation Function introduction 12-36VDC Input ZigBee RGBW Receiver Common Anode output (+) CH 1 (R) output (-) 1/R- CH 2 (G) output (-) 2/G- Prog. 3/B- CH 3 (B) output (-) 4/W- CH 4 (W) output (-)
  • Page 3 USER’S MANUAL 4. TouchLink to a ZigBee Remote Step 1: Method 1: Short press “Prog” button (or re-power on the device) 4 times to start Touchlink commissioning immediately, wait for the connected light to flash twice before proceeding. 180s timeout, repeat the operation.
  • Page 4 LCZG1019FA-RGBW 6. Factory Reset Manually Step 1: Short press “Prog.” key for 5 times continuously or re-power on the device for 5 times continuously if the “Prog.” key is not accessible. Step 2: Connected light will blink 3 times to indicate successful reset.
  • Page 5 USER’S MANUAL 8. Find and Bind Mode Step 1: Short press “Prog.” button 3 times (Or re-power on the device (initiator node) 3 times) to start Find and Bind mode (connected light flashes slowly) to find and bind target node, 180 seconds timeout, repeat the operation. 12V/24V/36V CVPSU AC Power...
  • Page 6 LCZG1019FA-RGBW 10. Delete Learning to a ZigBee Green Power Remote Step 1: Short press “Prog.” button 3 times (Or re-power on the device 3 times) to start delete Learning mode (connected light flashes slowly), 180 seconds timeout, repeat the operation.
  • Page 7 USER’S MANUAL 12. ZigBee Clusters the device supports are as follows: Input Clusters • 0x0003: Identify •0x0004: Groups •0x0000: Basic • 0x0005: Scenes •0x0b05: Diagnostics •0x0006: On/off • 0x0008: Level Control • 0x0300: Color Control Output Clusters •0x0019: OTA 13. OTA The device supports firmware updating through OTA, and will acquire new firmware from ZigBee controller or hub every 10 minutes automatically.
  • Page 8 The device meets the essential requirements of the Directives LVD 2014/35/UE, EMC 2014/30/UE, RAEE 2012/19/UE, RoHS 2011/65/UE, Ecodesign 2009/125/CE reg. (UE) 1194/2012, Energy label Arena Luci srl via Svizzera 12/14 46042 Castel Goffredo (MN), Italy Tel. +39 0376 782411 Fax +39 0376 780973 www.arenaluci.com info@arenaluci.it...

Table of Contents