4.1.
ZERO SETTING
Prior to operation, perform a zero setting. To do this place the gauge foot on the zero set bar (fig.1 item 10) and press the probe down
until it is level with the base then press the 'ZERO' button, the gauge has been set to zero when the LCD displays '0.00'. Note: After
zero setting, the gauge retains this setting until the 'ZERO button is pressed again or battery is removed.
4.2.
PRODUCT USAGE
Switch on the gauge by pressing the ON/OFF button. Place the gauge foot across the tyre tread with the probe tip over the tyre groove.
Press the probe down until it stops moving then read the display. The pressure exerted by the tip of the measuring probe must be uniform
and constant to ensure correct and stable readings. Do not press too hard or incorrect results will be recorded.
5. MAINTENANCE
5.1.
BATTERY INSTALLATION/REPLACEMENT
NOTE: The battery should last for one year of continuous use. If the display is blank or the digits are flashing the battery voltage is too
low, replace the battery with a new CR2032 power cell. If the digits do not change when buttons are pressed or probe is moved, remove
the battery for 1 minute to reset the unit. The battery should be removed if the gauge is not to be used for a long period.
5.1.1.
Remove battery cover (fig.2.A) by sliding it backwards and lifting off.
5.1.2.
Remove rubber spacer (fig.2.B) and exhausted battery (fig.2.C) and fit replacement with +ve side uppermost. Place the rubber spacer on
top of the battery and press it into the recess. Slide the cover back into place.
Dispose of old battery in a safe and approved manner. If the display fails to alter when the slide is moved, remove the battery, wait at least
1 minute and then refit the battery.
5.2.
CALIBRATION
5.2.1.
Calibration is valid for 12 months after the packaging is opened.
5.2.2.
We do not supply a certificate of calibration the for initial period. We recommend that the unit is returned to us annually for re-calibration.
A test certificate can be issued at this time. For re-calibration quote VS0563CAL
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
BATTERY REMOVAL
Refer to section 5.1.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
fig.2
01284 703534
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
VS0563 | Issue:7 (H) 26/02/20

Advertisement

loading