Available languages

Mode/Reset Button to Change LED Functionality
Tapping the Mode/Reset button briefly switches the port indicator between displaying port link speed and PoE
status.
The following chart shows the LED indicators of the XMS-2624P along with an explanation of the indicator's
properties:
Indicator Name
System
Port Link/
Act Status
1-26
Port PoE
Status 1-24
Note: At startup, the port LEDs will flash briefly during a self-test.
Mode/Reset Button to Reset/Restore
The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch, or to restore
the switch to factory default settings.
To Reboot/Reset the Switch:
With the XMS-2624P powered on, press the Reset button for approximately three seconds until the Link/Act and
PoE LEDs both light, then release the button.
CAUTION: Do not hold the button for more than four seconds. Doing so could erase all settings
and restore factory defaults.
To Restore Default Settings:
With the XMS-2624P powered on, press and hold the Reset button approximately eight seconds, until both the
Link/Act and PoE LEDs turn off, then release the Reset button and the switch automatically restores factory default
settings and reboots. Once the System LED starts flashing again, the XMS-2624P is running with factory defaults.
CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.
Safety instructions
This product should be installed in compliance with installation rules, preferably by a qualified electrician. Incorrect installation and
use can lead to risk of electric shock or fire.
Before carrying out the installation, read the instructions and take account of the product's specific mounting location.
Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions. All Legrand
products must be opened and repaired exclusively by personnel trained and approved by Legrand. Any unauthorised opening or
repair completely cancels all liabilities and the rights to replacement and guarantees.
Use only Legrand brand accessories.
State
Green Flashing
Green On
Red On
Off
Green
Yellow
Flashing
Off
Green
Yellow
Off
Description
Indicates normal operation.
Indicates a malfunction. Contact support.
Indicates power-on system initialization.
Indicates startup/initialization process or
that power is not on.
1000Mbps device connected to the port.
10/100Mbps device connected to the port.
Port receiving or transmitting data.
Nothing connected to the port.
Switch is providing PoE power to a device.
PoE is off due to a fault or because the
connected device is exceeding power limit.
Port disconnected or link failed.