Download Print this page

Rauland-Borg Telecenter IV Installation Manual

Hide thumbs Also See for Telecenter IV:

Advertisement

RAULAND-BORG CORPORATION

Table of Contents

Introduction ................................................................................................ 1
FCC Requirements ...................................................................................... 2
Initial System Installation and Checkout ..................................................
Configure Line-Link Modules .................................................................... 6
Install Field Wiring (Set External EEPROM Switch) ................................
Checkout Internal Communication System ............................................
Install Interconnect Wiring ........................................................................
Checkout Interconnect System .................................................................. 16

Introduction

This manual provides instructions for installing and testing a Telecenter IV. Except for the
procedure covering initial system installation and checkout, procedures for installing and
checking-out the internal and interconnected communications systems are kept separate.
Use only the procedures applicable to the site requirements.
Unless otherwise stated, the procedures assume the central chassis has been wired at the
factory, DIP switches have been preset, and the installer has a completed copy of the
System Planning Worksheet.
Special Note:
If interconnecting a Telecenter IV to the public utility, read the
before beginning installation.
©
1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89)
Telecenter® IV
Installation
3450 West Oakton Street, Skokie, Illinois 60076-2951
l
l
Page
3
8
12
13
Requirements
FCC
Installation
KI-1583A
(708) 679-0900
Page 1 of 20

Advertisement

loading

Summary of Contents for Rauland-Borg Telecenter IV

  • Page 1: Table Of Contents

    Physical Number Layout Planning Worksheet (blank form) ....17 Introduction This manual provides instructions for installing and testing a Telecenter IV. Except for the procedure covering initial system installation and checkout, procedures for installing and checking-out the internal and interconnected communications systems are kept separate.
  • Page 2: Fcc Requirements

    Installation FCC Requirements Rauland-Borg’s Model TC4171 (COA Module) conforms to the requirements of the Federal Communica- tion Commission’s Rules and Regulations, Part 68, which governs the connection of circuitry to protect the telephone network. The user must be aware of the requirements pertaining to the installation and the operation of this protective device.
  • Page 3 Perform Initial System Installation and Checkout Summary: Install the Telecenter IV cabinets in an office environment so that free access is provided to the front and rear. Ensure proper grounding and power is provided. Verify the system oper- ates prior to proceeding with the subsequent installation and checkout procedures.
  • Page 5 installation Connect the power source and verily the pilot lamp, located by the power switch on the Step 12. Central Control Assembly, remains off. Step 13. Place the power switch to the ON position (up) and verily the pilot lamp lights. Note: Other lamps may also be seen to illuminate within the TC4001.
  • Page 6: Configure Line-Link Modules

    320-335 000101 001101 208-223 010101 011101 464-479 80-95 336-35 1 000110 96-111 001110 224-239 010110 011110 480-495 352-367 000111 112-127 1 5 001111 240-255 011111 496-511 010111 368-383 Page 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89) 6 of 20 ©...
  • Page 7: Configure Speaker (And Single Link Staff Phone) Control Boards

    0001111(S) 391-415 0010000(S) 416-440 0000001(S) 41-65 0000110(S) 166-190 0001011(S) 291-315 0010001(S) 0000010(S) 66-90 0000111(S) 191-215 0001100(S) 316-340 441-465 OOlOOlO(S) 466-490 0000011(S) 91-115 0001000(S) 216-240 0001101(S) 341-365 0010011(S) 491-511 © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89) Page 7 of 20...
  • Page 8: Install Field Wiring (Set External Eeprom Switch)

    If two completely different programming set ups are required for day and night use, connect the EEPROM switch as shown in Drawing KMO896. This is a custom alternative to the standard day/night function. © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89) Page 8 of 20...
  • Page 10 To reduce crosstalk in speaker applications, wire the D and E terminal connections of above. odd numbered single-link staff phone circuits opposite those of even numberd circuits. © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89) Page 10 of 20...
  • Page 11 Wherever possible, these are factory installed. However, large amplifiers may be temporarily removed from a rack for shipment. If so, they should be mounted and connected to existing wiring. Rauland-Borg Corporation (Orig. © 1989 10/88; Rev. l/89)
  • Page 12 GR2 to show lines in use. Step 13. If a TC4400 Call Control Console is installed, check it according to the procedure in its manual, KI-1559. Page 12 of 20 © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89)
  • Page 13: Install Interconnect Wiring

    Do not program the line for single digit dialing (Location Codes 64016-34). Assign a non-accessible architectural number (901 if using dial ‘9’ for outside access). Set the hunt bit (A:8) off on the preceeding line. © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89) Page 13 of 20...
  • Page 15 View - Not all components shown.) RELAY 2.2 M (l/4 watt) resistor inserted across terminals 1-2 and 3-4 after removal of jumper across terminals l-2 and 3-4. © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89) Page 15 of 20...
  • Page 16: Checkout Interconnect System

    Once the above tests have been completed and the hardware and wiring are known to be okay, Telecenter software can be altered to meet system requirements. (Refer to the Programming manual, Kl-1584.) 16 of Page © 1989 Rauland-Borg Corporation (Orig. 10/88; Rev. l/89)