Print Head Replacement Procedure
Preparation
Alta machine
Used print head
Replacement unit
Tools
Needle-nose pliers
Hex wrench (M3) (included in the Alta box)
4. Remove the hose.
4.1 Push the collar down.
4.2 Pull the hose.
6. Remove the connector. Pinch the side of the connector and pull
up
(DO NOT PULL THE
WIRE).
Remove the print head
1.
Remove the filament and wait for the print head to cool.
2. Remove the build plate.
3. Move the print head to the bottom of the platform. Adjust the
print head position so that it rests in the center.
5. Remove the M3 screws with the hex wrench.
7.
Remove the joint screws (3 pieces).
7.1 Hold the nut piece in place with the needle-nose pliers.
7.2 Remove the screw with the hex wrench.
8. Remove the print head.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Alta and is the answer not in the manual?

Questions and answers

Summary of Contents for Silhouette Alta

  • Page 1 Replacement unit Tools Needle-nose pliers Hex wrench (M3) (included in the Alta box) Remove the filament and wait for the print head to cool. 2. Remove the build plate. 3. Move the print head to the bottom of the platform. Adjust the print head position so that it rests in the center.
  • Page 2 Silhouette Alta® Print Head Replacement Procedure Insert the new print head Determine the direction of the print head. 2. Attach the nozzle with the screw and nut. 1.1 Attach the print head so that the wire connector is facing NOTE: DO NOT TIGHTEN THE SCREW TOO TIGHTLY.