H3C S7502 Installation Manual
H3C S7502 Installation Manual

H3C S7502 Installation Manual

Ethernet switch
Hide thumbs Also See for S7502:

Advertisement

Quick Links

Installation Manual
H3C S7502 Ethernet Switch
Chapter 4 Hardware Installation .................................................................................................. 4-1
4.1 Confirming the Installation Preparations............................................................................ 4-1
4.2 Installation Flowchart ......................................................................................................... 4-1
4.3 Mounting the Switch to the Designated Position ............................................................... 4-2
4.3.1 Mounting the Switch onto a 19" Standard Rack...................................................... 4-2
4.3.2 Mounting the Switch on the Tabletop...................................................................... 4-3
4.4 Installing Modules of the Switch ........................................................................................ 4-3
4.5 Connecting the Grounding Cable and Power Cables........................................................ 4-3
4.5.1 Connecting the Grounding Cable............................................................................ 4-3
4.5.2 Connecting the AC Power Cable ............................................................................ 4-5
4.5.3 Connecting the DC Power Cable ............................................................................ 4-6
4.5.4 Connecting the PoE Power Cable........................................................................... 4-8
4.6 Connecting Interface Cables ............................................................................................. 4-9
4.6.1 Connecting the Console Cable ............................................................................... 4-9
4.6.2 Connecting the COM Port Cables......................................................................... 4-10
4.6.3 Connecting Category-5 Cables ............................................................................. 4-11
4.6.4 Connecting Fibers ................................................................................................. 4-12
4.7 Cabling............................................................................................................................. 4-14
4.7.1 Table-Mounted Switch .......................................................................................... 4-14
4.7.2 Rack-Mounted Switch ........................................................................................... 4-14
4.8 Cable Binding................................................................................................................... 4-14
4.8.1 Use of Labels ........................................................................................................ 4-14
4.8.2 Precautions for Cable Binding............................................................................... 4-14
4.9 Checking the Installation.................................................................................................. 4-18

Table of Contents

i
Table of Contents

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S7502 and is the answer not in the manual?

Questions and answers

Summary of Contents for H3C S7502

  • Page 1: Table Of Contents

    Installation Manual H3C S7502 Ethernet Switch Table of Contents Table of Contents Chapter 4 Hardware Installation ....................4-1 4.1 Confirming the Installation Preparations................4-1 4.2 Installation Flowchart ......................4-1 4.3 Mounting the Switch to the Designated Position ............... 4-2 4.3.1 Mounting the Switch onto a 19” Standard Rack............4-2 4.3.2 Mounting the Switch on the Tabletop..............
  • Page 2: Chapter 4 Hardware Installation

    H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Chapter 4 Hardware Installation The S7502 is designed for indoor application and must be fixed when applied. 4.1 Confirming the Installation Preparations Make sure that you have read Chapter 3 carefully. All requirements introduced in Chapter 3 have been met.
  • Page 3: Mounting The Switch To The Designated Position

    4.3.1 Mounting the Switch onto a 19” Standard Rack The S7502 has an integrated chassis and should operate indoors. Figure 4-2 Mount an S7502 Ethernet switch onto a 19” standard rack Take the following installation steps. Step 1: Confirm the following before installation: The rack has been well fixed.
  • Page 4: Mounting The Switch On The Tabletop

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation 4.3.2 Mounting the Switch on the Tabletop Step 1: Confirm the following before installation: The table is firm enough to hold the switch and cables. No obstacles around the table that may interfere with the installation.
  • Page 5 Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Note: Each cabinet has a grounding strip, to which you can connect the grounding cable of a switch. II. Other grounding environment Hereafter introduced some methods for grounding the switch in different environment.
  • Page 6: Connecting The Ac Power Cable

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Figure 4-4 Connect the grounding cable to the grounding body nearby If there is no grounding strip and no grounding body can be buried, and the Ethernet switch is AC powered, you can grounded through the PE wire of the AC power supply.
  • Page 7: Connecting The Dc Power Cable

    (3) Handle of power module (4) Power switch (5) Bail latch Figure 4-6 S7502 power module The power module has AC input socket with bail latch and a power LED on its front panel (The LED is described in 6.1.2).
  • Page 8 PGND: protection ground (You do not need to connect it because it is connected to the chassis from inside the power module). Figure 4-7 S7502 DC power module Follow these steps to connect the DC power cable: Step 1: Install the DC power plug components.
  • Page 9: Connecting The Poe Power Cable

    For the method of installing the PSE2500-A3, see the related manual shipped with the switch. (1) Grounding screw (2) RTN(+) terminal of of PoE power supply input (3) NEG(-) terminal of PoE power supply input Figure 4-10 Rear view of an S7502 PoE chassis...
  • Page 10: Connecting Interface Cables

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Follow these steps to connect the PoE power cable: Step 1: Loosen the mounting screw of the PoE terminal block on the rear panel of the switch. Step 2: Insert the -48V OT terminal of the DC power cable to the NEG (-) terminal of the switch and fasten the mounting screw;...
  • Page 11: Connecting The Com Port Cables

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Table 4-1 Console cable pinout RJ45 Signal DB-9 Signal II. Connect a Console cable Take the following steps to connect the Console cable when configuring the switch via a terminal.
  • Page 12: Connecting Category-5 Cables

    4.6.3 Connecting Category-5 Cables I. Introduction The 10Base-T/100Base-TX and 1000Base-T ports of an S7502 switch match RJ-45 connectors, and are MDI/MDIX auto-sensing. You can use category-5 cables to connect it. The following figure illustrates the appearance and pinouts of an RJ-45 connector.
  • Page 13: Connecting Fibers

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation 10Base-T/100Base-TX 1000Base-T Pinout Signal Function Signal Function Bi-directional data Reserved — BIDD+ cable D+ Bi-directional data Reserved — BIDD- cable D- Note: Tx refers to Outbound. Rx refers to Inbound.
  • Page 14 Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Fiber connectors are indispensable passive components in optical fiber communication system. Their application enables the removable connection between optical channel, which makes optical system debugging and maintenance more convenient and transit dispatching more flexible.
  • Page 15: Cabling

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Caution: When the optical port has not been connected with a fiber connector or its dustproof cover is open, there might be some invisible radiation emitted from the optical port. So do not stare into the optical port directly.
  • Page 16 Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Twisting Twisting Bending Bending Figure 4-17 Cable binding example I The radius of the curve at which a cable is bent should be no less than twice of the cable’s diameter. At the point where a cable runs out of a connector, the radius of the curve at which the cable is bent should be no less than five times of its diameter.
  • Page 17 Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation Figure 4-18 Cable binding example II Before bending the cables, bind them first. Mind that no tie binds the bended part of any cables, for fear of cable core breaking due to excessive stress. See the following figure.
  • Page 18 Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation For the cable terminals fixed with screw thread, the screws or nuts should be fastened and prevented from loosing. See the following figure; Flat Flat Flat Flat Spring Spring washer...
  • Page 19: Checking The Installation

    Installation Manual H3C S7502 Ethernet Switch Chapter 4 Hardware Installation 4.9 Checking the Installation Caution: Confirm that you have turned off the power before checking. Otherwise, improper connection may cause bodily injury or device damage. After installing the switch, please check if the items listed in the following table are normal.