MD Mustang Dynamometer Manual page 15

Digital air/fuel ratio (lambda) meter
Table of Contents

Advertisement

The scale will be automatically expanded to a 0-5V scale. Clicking the check mark in this
column switches the input back to either voltage or sample data mode.
4. Input in Use
Check the button if this input is actually hooked up. The LM-1 will record from each input
regardless if the input is actually connected to something or not. If it is not used, this check
mark allows you to prevent it to be included in the graph, printout or in the saved data file.
9.7.1 Loading and Saving Log Data
Click the 'Load' button to either download LM-1 Log data or re-load a previously recorded log file.
The log file data format is compatible with the DIF file format that most spreadsheet programs are
compatible with. Each log data file starts with a header that describes the usage of the inputs. To
save log data from the LM-1, press the 'Save' button.
9.7.2 Importing Input Descriptions.
As a convenience the input settings from a previously saved log file can be quickly re-loaded using
the 'Import Input Descriptions' button. This saves you from re-entering all the input settings.
9.7.4 Resetting the log in the LM-1.
This button is grayed out if no log data is present in the LM-1. Pressing it clears the log data in the
LM-1 unit.
- 15 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lm-1

Table of Contents