Advertisement

Quick Links

h/p/cosmos
model names
®
h/p/cosmos
parawalk
2,44m
®
®
h/p/cosmos
parawalk
3m
®
®
h/p/cosmos
parawalk
4m
®
®
h/p/cosmos
parawalk
5m
®
®
file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc
© 2016 h/p/cosmos sports & medical gmbh
h/p/cosmos
parawalk
®
original instruction for use
author: nf
email@h-p-cosmos.com
®
development, production, sales
h/p/cosmos
sports
medical gmbh
®
&
Am Sportplatz 8
DE 83365 Nussdorf-Traunstein
Germany
phone +49 86 69 86 42 0
fax
+49 86 69 86 42 49
service@h-p-cosmos.com
www.h-p-cosmos.com
version
version 1.1, revision 06.07.2016
order-no.: [cos14310pw-v1.1_hpc-en]
created 06.07.2016
printed 06.07.2016
service
&
page: 1 of 30

Advertisement

Table of Contents
loading

Summary of Contents for h/p/cosmos parawalk 2,44m

  • Page 1 +49 86 69 86 42 0 +49 86 69 86 42 49 service@h-p-cosmos.com www.h-p-cosmos.com version version 1.1, revision 06.07.2016 order-no.: [cos14310pw-v1.1_hpc-en] file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: nf email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 1 of 30...
  • Page 2 In case of alterations of the device or the additional equipment, the latest version of these instructions for use or the corresponding additional information should be always considered. The latest version of the instructions for use is always available in PDF version on the h/p/cosmos website: http://www.h-p-cosmos.com/en/company/downloads.htm It is strictly forbidden to perform any amendments of the technical design, technical specifications, labelling and configurations of this device and the accessories connected to it.
  • Page 3 All kinds of installation and repair work and most maintenance work are to be performed only by trained and authorized technicians who have been certified by h/p/cosmos. The following symbols will indicate which work can be done by the customer and which work has to be done by authorized technicians only: The customer/user should perform this maintenance and monitoring work.
  • Page 4: Table Of Contents

    Immediate maintenance ............................. 23 Regular inspections / examinations ........................24 Hygiene and cleansing ............................24 Spare parts & consumables ............................24 file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: nf email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 4 of 30...
  • Page 5 11.1 Instruction protocol, checklist ............................27 11.2 Instruction protocol, signatures ............................28 Appendix 2: Symbols ..............................29 Contact ..................................30 file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 5 of 30...
  • Page 6: Modeloverview

    ® medical device h/p/cosmos parawalk 2,44m ® ® h/p/cosmos parawalk ® ® h/p/cosmos parawalk ® ® h/p/cosmos parawalk ® ® file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 6 of 30...
  • Page 7: Introduction

    Once you have found the perfect setting for a patient you will want use this at the next visit straight away. Therefore, the pillars of the h/p/cosmos parawalk ® have an integrated reading scale. With the help of the scale you can exactly determine the current position and reproduce simply at the next training session.
  • Page 8: Intended And Forbidden Use

    & 3 Intended and forbidden use The intended use, discussed in the following, can be performed with any h/p/cosmos parawalk system. ® 3.1 Intended use rehabilitation mobilization training gait training and therapy recreational fitness training 3.2 Forbidden use Do not modify the system and do not connect to other equipment which is not explicitly declared as compatible by all involved manufactures.
  • Page 9: Safety Notes, Warnings, Precautions

    Animals are not allowed to use the device and must not go too near (4 m distance). It is prohibited to use the device under the influence of alcohol, drugs and/or anaesthetics. file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016...
  • Page 10: Preparation Of The Device

    Before using the device, fix all four clamp levers. 4.4 During exercise The h/p/cosmos parawalk must only be used under permanent supervision of medical staff. Never set too high loads if the health and the condition of the subject/patient do not permit and a medical doctor has not authorized these loads.
  • Page 11: Operation

    Adjust the bar handrail to the desired height by pressing the push button and moving the handrail up- or downwards. Push button Move the bars horizontally to adjust the requested width. file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016...
  • Page 12 We have deliberately refrained from giving you standard settings for particular heights, because the adjustment can widely differ according to the posture and the individual situation of the testing person. file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016...
  • Page 13: Service

    All kind of installation and repair work as well as most maintenance work is to be carried out only by trained and authorized technicians who have been certified by h/p/cosmos. The following symbols will indicate which work can be done by the customer and which work has to be done by authorized technicians: The customer / user should perform this maintenance and monitoring work.
  • Page 14 Maintenance and repair of the devices (also opening of the device) have to be performed by service engineers authorized and certified by h/p/cosmos, preferably within the scope of a maintenance contract. The installation by unqualified personnel may cause damages or injury due to a malfunction. Never disassemble, repair, or modify the device yourself.
  • Page 15: Installation

    Within Germany, most devices are delivered and assembled by h/p/cosmos directly or by an authorised forwarder. If delivered by h/p/cosmos, the packaging will be removed and recycled.
  • Page 16: Installation H/P/Cosmos Parawalk

    7.5 Installation h/p/cosmos parawalk ® file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 16 of 30...
  • Page 17 Time needed for the entire assembling, 2 persons, approximately 90 minutes. 7.5.4 Work preparation Check all parts delivered by h/p/cosmos ® Clean intended space and floor file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 17 of 30...
  • Page 18: Work Steps

    Lay down connectors (Pos.50) Add pillar brackets (Pos. 60) with tap holes to the outside Add bottom frames (Pos. 20 + 40) file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 18 of 30...
  • Page 19 Put plastic rings on pillar arm Stick handrail trough plastic ring and pillar Fix handrail with washer and screw Plastic ring file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 19 of 30...
  • Page 20 Add second wooden plate carefully (if included) Close holes with plastic caps Check if all screws are tight and device is safe to use file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 20 of 30...
  • Page 21 Set anchor Apply torque Check, if all screws are bolted tight and check if device is safe to use 800 mm file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 21 of 30...
  • Page 22: Installation Checklist And Instruction Of The User

    Among other things, he ensures that at least the nine points of the following checklist have been performed and/or checked before the customer is introduced to the operation of the h/p/cosmos device. For detailed information and instructions on installation and commissioning please refer to all respective chapters in this manual.
  • Page 23: Maintenance And Safety Inspections

    2 m radius clear. 8.1 Preventive maintenance The h/p/cosmos authorised service technicians are happy to help you in case problems occur. Preventive maintenance can prevent future problems and is indispensable for the safety of technical devices. Therefore, ask our service department for an annual preventive maintenance contract, which is highly recommended by the manufacturer.
  • Page 24: Regular Inspections / Examinations

    The h/p/cosmos devices are neither sterile nor can they be sterilized. The surfaces of the device can be cleaned with a light moistened cloth. For disinfection h/p/cosmos recommends Bacillol plus which can be ordered from h/p/cosmos, order number [cos12179]. Before use of cleaning and disinfection substances, always test the compatibility of the substance at poorly visible places.
  • Page 25: Technical Data

    9.2 Economic life time The economic life time of the h/p/cosmos parawalk® is determined at common usage and application to 10 years. Every maintenance and repair work needs to be carried out by authorized h/p/cosmos technicians. For expendable parts a shorter life-time is due.
  • Page 26: Disposal

    10 Disposal Upon request and at the expense of the client, h/p/cosmos might take over the disposal of old or defective devices. Please contact service@h-p-cosmos.com for a detailed offer. Note the information for possible disposal of the running machine parts or components through the client or a subcontractor.
  • Page 27: Appendix 1: Protocols

    After the instruction is completed, the instruction protocol is to be signed by the h/p/cosmos technician and all trained persons. Signed instruction protocol, signed delivery note and the registration form are to be sent to h/p/cosmos.
  • Page 28: Instruction Protocol, Signatures

    This will furthermore result in loss of liability and warranty. Please fill out the instruction protocol and send it back to h/p/cosmos by Fax to +49 86 69 86 42 49, by email to sales@h-p-cosmos.com or by mail:...
  • Page 29: Appendix 2: Symbols

    IEC 60417-5032-2 connection point for Neutral line Warning of hot surfaces IEC 60445 file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 29 of 30...
  • Page 30: Contact

    Am Sportplatz 8 DE 83365 Nussdorf-Traunstein Building 2 (picture below) h/p/cosmos sales & service Feldschneiderweg 5 DE 83365 Nussdorf-Traunstein file: \\quasarf\erp$\article\cos14310pw-v1_1_hpc-en\20160706_cos14310pw-v1.1_hpc-en_instruction_for_use_h-p-cosmos_parawalk.doc © 2016 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 06.07.2016 printed 06.07.2016 page: 30 of 30...

This manual is also suitable for:

Parawalk 3mParawalk 4mParawalk 5mCos30018 l2.44Cos30018Cos30019 ... Show all