Control unit with touch-screen display

Advertisement

Funkce / Function
EST-2 device function comprises of several function elements, i.e. the total of three basic devices, units to busbar CIB. Jsou to IDRT2-1, IM2-140M a KEY2-01.
Not all function elements of the above three basic devices are implemented in EST-2.
The setting menu enables to define the menu language, screen saver, sleep mode, brightness setting, and initial screen option.
The button panel can be optionally configured in the setting menu as required. 4 basic button templates are available - 2x2, 2x3, 3x3, 3x4. The setting
menu of the button configuration enables to add a symbol, icon from preset offer (48 various symbols) to individual buttons, or. fitting into the button 3
alphanumeric characters.
The button screen
The function programming of iNELS system to individual buttons on EST-2 device screen is performed identically to the programming of other digital
inlets, events in unit IM2-140M. The specified digital inputs enable using only parameter A and D. The inputs do not enable using a recognize parameter
I – negated output, and parameter B – balanced input and also double balanced input parameter. The buttons are identical with binary inputs of unit IM2-
140M (see figure layout). The buttons can be configured identically to the wall mounted controllers WSB both for long and short pressing (>1.5s).
4 colour indicators placed in the top left corner of the screen are connected with the digital outputs. Each of four colour indicators is independently
controllable and programmable. Green and blue indicator is connected with outputs RE1, RE2 in device KEY2-01 in the device administrator. Yellow and red
indicators are interconnected with outputs HAND and MAN in device IDRT2-1 in the device administrator.
Thermoregulation screen
The thermoregulation control screen enables to regulate the temperature of selected heating circuit within scope +/- 5°C on display EST-2. The buttons for
the temperature control of the heating circuit are connected with analogue output, temperature regulation of unit IDRT2-1 in the device administrator.
4 colour indicators placed in the top left corner of the screen are connected with the digital outputs. Each of four colour indicators is independently
controllable and programmable. Green, blue, yellow and red indicators are interconnected with outputs ON, LED, HAND and MAN in device IDRT2-1 in the
device administrator.
The screen for controlling RGB lights and light sources
EST-2/RGB screen includes basic regulation and control elements and buttons for controlling the RGB light sources. The screen is connected with device
ADC2-40M to busbar CIB. The control screen function of RGB is set in such way the individual colour elements R, G and B are interconnected and simulate
the signal level on analogue inputs 1 to 3, and the resulting brightness of the light is connected and simulated on the analogue input 4. In order to make
the simulation from RGB screen functioning, it is necessary to set voltage range 0-5 V on individual analogue inputs in IDM.
The control screen RGB comprises of several elements and buttons.
- Long pressing (touch) of button ON/OFF controls the central setting of RGB elements and the light brightness - on/off
- The buttons
in the screen upper part include the light brightness setting function from 0-100% in step 5% (see the indicator of adjustable brightness %)
- Buttons
in the screen lower half include the colour comfort setting function and accelerated control of RGB light. The buttons include the arresting
function. Upon pressing button
is indicated in the RGB light source output by means of mixing the elements with resulting white colour. Then we can regulate only the brightness
intensity on the output. Upon pressing (touch) button
button „light on with colour as per RGB" is arrested. Now reset the analogue inputs values of individual RGB colour elements as per the preset cursor in
the colour wheel of RGB scale on screen EST-2/RGB.
4 colour indicators placed in the top left corner of the screen are connected with the digital outputs, and their interconnection with the outputs is identical
to the screen with buttons.
Info
specifies information related to the device and firmware version. Using the icon
returns back to the button panel.
The top right corner of the screen includes the system time specification. The display system time is connected with unit KEY2-01 in the device administrator
If you want to change the design of the button screen, it is always necessary before configuring icons (buttons) to RESET the device.
All inputs and outputs of EST-2 unit can be freely programmed including the parameter setting by means of IDM program.
Basic screen versions of EST-2:
IN1
IN4
IN7
IN10
Button for moving between screens
„white light on", the analogue inputs are automatically set to the maximum value of individual colour elements which
„light on with colour as per RGB" the button
IN2
IN3
IN5
IN6
IN8
IN9
IN11
IN12
Info on
device
„white light on" is automatically blocked, and
provides transfer to menu Setting used for editing EST-2. Icon
Circuit
temperature
correction Decrease
brightness
Illumination in
color based on
RGB
Settings
Legend:
EST-2=> settings menu=>item selection=>2x2 - input IN1- IN4
EST-2=> settings menu=>item selection=>2x3 - input IN1- IN6
EST-2=> settings menu=>item selection=>3x3 - input IN1- IN9
EST-2=> settings menu=>item selection=>3x4 - input IN1- IN12
Increase
brightness
Output ON/OFF
button
Illumination in
white