Summary of Contents for viZaar INVIZ BIG

  • Page 2 First models of the INVIZ BIG series and For questions, which have not been previous are in the market since about 10 answered by this instruction manual,...
  • Page 3 The device has for the consequences of faulty inspection been conceived exclusively for industrial results, which were achieved with the device.
  • Page 4 At the same time, protective glasses must gloves! Considerable risk of getting always be worn while operating the probe. adjusted! Never operate the device under conditions which do not comply with the operating conditions or storage conditions described in the instructions manual! www.vizaar.com...
  • Page 5 This can in any case be a compulsory The device must be transported exclusive- packed in the transport case only ly in the transport case conceived for it by according to the instructions at hand. the manufacturer. The device and the corresponding accessories must be www.vizaar.com...
  • Page 6 (e.g. danger from rotating inspection procedures like eddy current plant components) or cooled down. or radiography tests are being undertaken Exclusively the viZaar accessory articles or spare parts described in this instructions manual may be used in connection with the device.
  • Page 7 (getting stuck). Be careful employing centering tools to the probe. Faulty operated or wrong chosen centering trollies or rings can cause the probe getting stuck inside tubes and affiliated bends behind obstacles, bends and weldings etc. www.vizaar.com...
  • Page 8: Table Of Contents

    Integrated text generator Getting Started Care, maintenance and repair Cleaning of the system Maintaining of the O-ring Maintenance by the manufactorer Transport Customer service Guarantee, technical data and conformity Guarantee General device specifications Disposal of the device after end of life-expectancy www.vizaar.com...
  • Page 9: Structure And Start-Up

    DIM: H 635 x W 510 x D 365; PE; Weight empty 12,25 kg ‚Open here’ 1.1a ‚Push center and lift to unlock’ 1.1b ’ Pull-out lever Press the tab for sliding the lever ‚Wheels’ 1.1c www.vizaar.com...
  • Page 10 3 ‚Accessory pouch’ 4 ‚Card Reader’ 5 ‚Remote control’ 6 ‚Accessory box’ 7 ‚Packing drawers opened for remo- valt 1 ‚Fix magic arm insert here’’ 2 ‚Handle for carrying’ 3 ‚Feet’ 4 ‚Transport position for scope camera’ 1.1f www.vizaar.com...
  • Page 11 1 ‚Counter operation hrs’ 2 ‚PS2 keyboard for option text generator’ 3 ‚S-Video video out (only in combination with option data display modul’ 1.1i 4 ‚BNC composite video out’ 5 ‚Connector umbilical to LCD’ 6 ‚Date of manufacturing, SN’ www.vizaar.com...
  • Page 12: Accessories

    1.2 Accessories Scope of delivery version basic device in optional transport: 1 INVIZ big 2 Umbilical cord for LCD or of the simple operation pendant 3 Accessory pouch with 3.1 Power cord D, UK or US 3.2 BNC Video cord 3.3 BNC to RCA video adapter...
  • Page 13: Initial Operation

    Fire Wire / PCMCIA case of insufficient cooling, there can be :: INVIZ image recorder damage to the LED. Please contact your viZaar representant for any further question to this important issue. INVIZ camera system DVD recorder Monitor...
  • Page 14 Only NTSC or PAL monitors / VCR’s will allow to correctly operate with your INVIZ scope. The INVIZ LCD image recorder will allow to run on NTSC and PAL through it’s integrated auto-detect function. www.vizaar.com...
  • Page 15: Further Functions Of The Basic System

    www.vizaar.com...
  • Page 16: Focusing

    :: Rotate front housing until desired focus is set. :: Hold back section, while rotating front housing. :: Do not remove front housing unnecessarily. LED will shut-off at nearest fokal point. :: Clockwise: focus farther :: Conter clockwise: focus near 1.5a www.vizaar.com...
  • Page 17: Product Specifications

    :: big 2 Product specifications INVIZ big :: CCD push camera for visual inspections of tube, pipes and other cavities. :: PAL or NTSC composite video out (see product label). :: Probe length 30 meter, 50 meter, 80 meter (see product label).
  • Page 18: Supplementary Equipment

    The rod will Even without breaking, the employment of push poles training. In case of doubt, please ask viZaar for further can disable you to retrieve the camera – head with the training or technical assistance. Never push the poles from the inspected piping.
  • Page 19 1,5 meter poles need to be used 3.1a 3.1b instead of the reel. The poles / rod can be connected to the camera head or to the centering tool. disconnect from camera head connect to camera head 3.1c 3.1d 3.1e 3.1f break store connector here www.vizaar.com...
  • Page 20: Option Centering Tools And Trollies

    Always assure all Centering tools are necessary to perform tool always consider components screws of the inspections with the INVIZ big in larger obstacles, big weldings, centering tools are perfectly tubes and pipes, nevertheless, a side view damaged (oval) pipes, dirt tightened to not get lost or a straight view is employed.
  • Page 21 3 Supplementary equipment Option centering trolly adjust close to nominal diameter insert camera head 3.2e 3.2d attach push pole 3.2f 3.2c www.vizaar.com...
  • Page 22: Option Side View Prism

    Do not tighten the thread 3.3b NEAR onto the distance ring! Far view= move lens towards camera housing. Softly clean prism surface with a cotton-tip (Q-tip) dipped into 80% alcohol. 3.3c www.vizaar.com...
  • Page 23: Option Motorized Side View Mirror

    96% inspection of the inner wall surface due to general design. Softly clean prism surface with a cotton-tip (Q-tip) dipped into 80% alcohol. Remark: A standard INVIZ BIG must be prepared at viZaar / Albstadt to be able 3.4f operating a motorized side view! www.vizaar.com...
  • Page 24: Option Battery Operation

    3.5 Option rechargeable battery When battery capactiy seems Never use other charging to be reduced, NiMH cells The INVIZ Big can be equipped with a equipment than the sup- need to be replaced at the rechargeable NiMH battery. The system plied viZaar VE-100129-AE.
  • Page 25: Option Cable Counter

    When the counter is Only connect the counter to employed only careful the system when it is The INVIZ BIG inspection system can be pushing and pulling of the shut-off. equipped with an optional special digital epoxy fibre poles is allowed.
  • Page 26 :: button up ‘B’ or down ‘C’ will preset the counter to the wished value before starting the inspectin when not zero. Press button B and C for 3 seconds to reset counter to zero – usually at the beginning of the tube. metercounter metercounter pendant www.vizaar.com...
  • Page 27: Option 40Mm Head Adapter

    3.7 Option 40mm head adapter In case more light is necessary than the 3.7a remove 29mm head incl. distance ring standard 29mm head, viZaar is providing a 40mm diameter optical head with more LED – illumination power. After switching-off the system, the head can be replaced very simply by unscrewing the 29mm head incl.
  • Page 28: Image Recorder

    In the menu guidance, there are functions viZaar is always improving or extending which may not be relevant for your INVIZ the existing software of the system. In order to ensure that the image recorder.
  • Page 29 :: Adhere to the technical data sheets for lasting care and safekeeping of the storage media. 3.2b 3.2a 3.2c www.vizaar.com...
  • Page 30 A manual intervention in the selection of the video standard is activated via the setup menu. The operating pendant can be held freely, hung around the neck or fastened in the plant or to the system with the optional fastening arm. www.vizaar.com...
  • Page 31 Subsequently, the key remote control of the respective function and reverting to viZaar is not liable for the loss of image or the previous menu point. video data under any circumstances.
  • Page 32 (The next 12 images are displayed. In case there are Change directories no new images, no miniature images are displayed New folder Create a new directory in order to select “Cancel” or press starting from the lower right corner.) www.vizaar.com...
  • Page 33 Press functions: Deletion of one or several files (A file name dialogue appears, wherein the further procedure must be confirmed.) Delete Select in gallery menu. Enter the first 6 alphabets of Press the file name as follows: Press www.vizaar.com...
  • Page 34 (The foleder selection sub-menu shows a list of all Long date and time: time to half of , but video clips are available folders on the Compact Flash Card.) reproduced in full time resolution on the PC under quick time. in order to quit the editor mode. www.vizaar.com...
  • Page 35 Voltage saving mode: Leave the setting on “OFF” as long as no battery-supported INVIZ system is in use. The display is switched-off after the adjusted time setting. For a restart, the system must be switched-off and then switched-on once again. www.vizaar.com...
  • Page 36: Integrated Text Generator

    Both the text and the text back- superimpositions from viZaar engineers. description in the table. The reason for ground can be represented in colour. A Wouldn’t the continued superimposition...
  • Page 37 Ctrl + C Cursor on / off Alt + - Reduce background colour (see colour selection) Ctrl + Alt + Delete Triggers a warm start Ctrl + I System information Ctrl + L Switches the superimposed logo on / off www.vizaar.com...
  • Page 38 F12. Page up and / or Page down. To load a 3.3a fixed page on the screen, it’s not necessary to recall the entry window. Use F2 … F11 (pages 1 to 10) to load. 3.3b 3.3c www.vizaar.com...
  • Page 39 Status line 3 Status line 4 3.3e Warm start With the key combination Ctrl + Alt + Del you can trigger a restart of the system without switching-off the endoscope. A warm start is not necessary in normal operation. www.vizaar.com...
  • Page 40: Getting Started

    :: Mount your equipment basically in such releasing the probe from the control destroy the camera head irreversibly. a manner, that it stands absolutely device. viZaar even makes service Fresh weld seams in pipelines have high securely. Fundamentally, the probe does technicians available for this difficult...
  • Page 41: Care, Maintenance And Repair

    AG to devices, which are caused by repair VT repair service :: Check of the probe, of the extra-flexible attempts by unauthorized persons.
  • Page 42: Guarantee, Technical Data And Conformity

    7.2 General device specifications life-expectancy Device dimensions viZaar guarantees, that all video endoscope All the devices of viZaar described in this system components are faultless in instructions manual shall be taken back respect of material and fabrication. The All individual device dimensions are listed...
  • Page 43 Affix www.vizaar.com...