Leak Test; Fixing The Installation Plate - Samsung ND022QHXEA User Manual

Wall mounted type series
Hide thumbs Also See for ND022QHXEA:
Table of Contents

Advertisement

Fixing the Installation Plate

ND£ª£ª£ªQHX£ª£ª _IB IM_32063A_E.indd 33
120
68
140
68
Performing Leak Test & Insulation

Leak test

LEAK TEST WITH NITROGEN(before opening valves)
In order to detect basic refrigerant leaks, before recreating the
vacuum and recirculating the R410A, it's responsible of installer
to pressurize the whole system with nitrogen(using a pressure
regulator) at a pressure above 4.1MPa(gauge).
LEAK TEST WITH R410A(after opening valves)
Before opening valves, discharge all the nitrogen into the
system and create vacuum. After opening valves check leaks
using a leak detector for refrigerant R410A.
 The designs and shape are subject
to change according to the model.
CAUTION
Discharge all the nitrogen to create a vacuum and
charge the system.
installing your air conditioner _33