Download Print this page

LIBERTY AV SOLUTIONS DigitaLinx DL-PSU8 Quick Install Manual

Hide thumbs Also See for DigitaLinx DL-PSU8:

Advertisement

Quick Links

DL-PSU8 Quick Install Guide
This guide is for quick installation only.
For complete owners manual go to www.libav.com or use a QR reader to access the
manual via QR code below.
Scan QR Code with your Smart-phone or Tablet
Rev 191204
11675 Ridgeline Drive
Phone: 719-260-0061
Colorado Springs, CO
Toll-Free: 800-530-8998
80921
Fax: 719-260-0075

Advertisement

loading
Need help?

Need help?

Do you have a question about the DigitaLinx DL-PSU8 and is the answer not in the manual?

Questions and answers

Summary of Contents for LIBERTY AV SOLUTIONS DigitaLinx DL-PSU8

  • Page 1 DL-PSU8 Quick Install Guide This guide is for quick installation only. For complete owners manual go to www.libav.com or use a QR reader to access the manual via QR code below. Scan QR Code with your Smart-phone or Tablet Rev 191204 11675 Ridgeline Drive Phone: 719-260-0061 Colorado Springs, CO...
  • Page 3: Product Overview

    DL-PSU8 Quick Guide Product Overview The DL-PSU8 is an integrated switching power supply designed for converting AC into DC power. It provides 2 AC input channels and 8 DC output channels. Input voltage is 100~240VAC, output voltage is selectable per output channel; 5/12/18/24/48V DC. The max power consumption of a single DC channel is 12W when using the 5VDC setting and 15W when using the 12/18/24/48VDC settings.
  • Page 4 DL-PSU8 Quick Guide Front / Back Panel View 1. AC1 AC2 - Input AC Source Indicators • When GREEN; AC input is powered on with normal output • When RED; AC input is not powered • When ORANGE - Input voltage is too low or too high 2.
  • Page 5 DL-PSU8 Quick Guide Voltage, Power, Current Per Output VOLTAGE POWER MAX CURRENT PER (WATTS MAX) OUTPUT 5V DC 2.4A 12V DC 1.25A WARNING: DO NOT EXCEED MAXIMUM 18V DC .83333A RATINGS 24V DC .625A 48V DC .3125A...
  • Page 6 DL-PSU8 Quick Guide Cabling Wiring Requirements Ethernet Control The DL-PSU8 may be controlled via Ethernet using web browser for web server control or by using telnet commands using port 4001. See owners manual online at www.libav.com for complete API. The TCP/IP port requires a standard straight-through Category 5 or greater cable with the TIA/EIA-568B crimp TIA/EIA-568B pattern for optimal operation.
  • Page 7: Technical Specifications

    DL-PSU8 Quick Guide Technical Specifications Input/Output Connections Inputs Two (2) IEC 320 C13/C14 Male Input Voltage 100~240VAC 50~60Hz Outputs Eight (8) 2-Pin terminal block Output Voltage 5V, 12V, 18V, 24V or 48V; selectable. Maximum output power consumption of 5V:12W signal channel 12/18/24/48V:15W Control Ethernet...
  • Page 8 Thank you for your purchase. For Technical Support please call our toll free number at 800-530-8998 or email us at supportlibav@libav.com www.libav.com Digitalinx is a brand of: 11675 Ridgeline Drive Colorado Springs, Colorado 80921 USA Phone: 719-260-0061 Fax: 719-260-0075 Toll-Free: 800-530-8998...