LIBERTY AV SOLUTIONS DIGITALINX DL-PSU8 Owner's Manual

Hide thumbs Also See for DIGITALINX DL-PSU8:

Advertisement

Quick Links

DL-PSU8 Owners Manual
Rev 200422
11675 Ridgeline Drive
Phone: 719-260-0061
Colorado Springs, CO
Toll-Free: 800-530-8998
80921
Fax: 719-260-0075

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIGITALINX DL-PSU8 and is the answer not in the manual?

Questions and answers

Summary of Contents for LIBERTY AV SOLUTIONS DIGITALINX DL-PSU8

  • Page 1 DL-PSU8 Owners Manual Rev 200422 11675 Ridgeline Drive Phone: 719-260-0061 Colorado Springs, CO Toll-Free: 800-530-8998 80921 Fax: 719-260-0075...
  • Page 2 DL-PSU8 Owners Manual Important Safety Instructions » Please completely read and verify you understand all instructions in this manual before operating this equipment. » Keep these instructions in a safe, accessible place for future reference. » Heed all warnings. » Follow all instructions. »...
  • Page 3: Table Of Contents

    DL-PSU8 Installation Guide Table of Contents Product Overview ��������������������������������������������������������������������������������������������������������������������������������������� Product Contents ���������������������������������������������������������������������������������������������������������������������������������������� Front and Rear Panel ���������������������������������������������������������������������������������������������������������������������������������� Voltage, Power, Current Per Output ������������������������������������������������������������������������������������������������������������ Installation Instructions ������������������������������������������������������������������������������������������������������������������������������ Rack-mounting the Power Hub ��������������������������������������������������������������������������������������������������������������������� Connecting Devices ��������������������������������������������������������������������������������������������������������������������������������������� Apply Power �������������������������������������������������������������������������������������������������������������������������������������������������� System Control ������������������������������������������������������������������������������������������������������������������������������������������� Connect Ethernet Control ������������������������������������������������������������������������������������������������������������������������������...
  • Page 4: Product Overview

    DL-PSU8 Owners Manual Product Overview The DL-PSU8 is an integrated switching power supply designed for converting AC into DC power. It provides 2 AC input channels and 8 DC output channels. Input voltage is 100~240VAC, output voltage is selectable per output channel; 5/12/18/24/48V DC. The max power consumption of a single DC channel is 12W when using the 5VDC setting and 15W when using the 12/18/24/48VDC settings.
  • Page 5: Front And Rear Panel

    DL-PSU8 Installation Guide Front and Rear Panel 1. AC1 AC2 - Input AC Source Indicators • When GREEN; AC input is powered on with normal output • When RED; AC input is not powered • When ORANGE - Input voltage is too low or too high 2.
  • Page 6: Voltage, Power, Current Per Output

    DL-PSU8 Owners Manual Voltage, Power, Current Per Output VOLTAGE POWER MAX CURRENT PER (WATTS MAX) OUTPUT 5V DC 2.4A 12V DC 1.25A WARNING: DO NOT EXCEED MAXIMUM 18V DC .83333A RATINGS 24V DC .625A 48V DC .3125A Installation Instructions Rack-mounting the Power Hub Attach the supplied rack ears to the sides of the DL-PSU8.
  • Page 7: System Control

    DL-PSU8 Installation Guide System Control Connect Ethernet Control The DL-PSU8 can be controlled via Ethernet through a web browser interface or can be controlled using Telnet commands The TCP/IP port requires a standard straight-through Category 5 or greater cable with the TIA/EIA-568B crimp pattern for optimal operation.
  • Page 8: Web Gui Settings

    DL-PSU8 Installation Guide Web GUI Settings Switcher Control Connecting to Web GUI Control Network a PC computer and the DL-PSU8 then open a web browser in the PC and type in IP address of the DL-PSU8. The default IP address is 192.168.0.178 so be sure the computer you are using to connect to the DL-PSU8...
  • Page 9: Port On And Off Control

    DL-PSU8 Installation Guide Port ON and OFF Control The CONTROL menu allows you to power ON and OFF DC power ports 1-8 on the DL-PSU8. Click On / Off on the DC power port you would like to turn on or off. Click All On or All Off to turn ALL ports on or off.
  • Page 10: Port Voltage Settings

    DL-PSU8 Installation Guide Port Voltage Settings The Voltage Settings menu allows you to set the voltage for DC ports 1-8 Choose the applicable voltage setting for the DC port, then click Confirm Locking Ports In the Voltage Settings menu you can lock or unlock the DC port voltage selection so the voltage cannot be changed accidentally.
  • Page 11: Network Settings

    DL-PSU8 Installation Guide Network Settings The Network menu allows you to set the network settings for the device. Navigate to the Network menu, select either DHCP or STATIC IP as the desired IP mode. If choosing DHCP, make sure the DL-PSU8 is connected to a router / network switch with a DHCP server support. When choosing the STATIC IP option, manually enter in the desired IP ADDRESS, SUBNET MASK and GATEWAY information, then click CONFIRM for changes to take place.
  • Page 12: Security Settings

    DL-PSU8 Installation Guide Security Settings The Password menu allows you to reset the password Navigate to the PASSWORD menu, enter in a user defined password in the password field, then click CONFIRM. Locking Front Panel Buttons The Password menu above will also allow you to lock or unlock the ON and OFF front panels buttons so they won’t be accidentally turned off physically by mistake.
  • Page 13: Control Commands

    DL-PSU8 Installation Guide Control Commands RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None Telnet Settings: User defined IP address (default IP address:192.168.0.178), port 4001 The commands are in ASCII format and are case sensitive DC Channel / Port Control Description Command Examples...
  • Page 14: Voltage Locking, Front Panel Control

    DL-PSU8 Installation Guide Voltage locking, Front panel control Description Command Examples >SetLock:{#} Command: Locks voltage selection on a port >SetLock:1 {#} = 1-8 = 1-8 (when left empty command Response: will lock ALL channels) <Locking 01 channel. >SetUnlock:{#} Command: Unlocks voltage selection on a port >SetUnlock:1 {#} = 1-8 = 1-8 (when left empty...
  • Page 15: System Commands

    DL-PSU8 Installation Guide System Commands Description Command Examples >GetSta Command: Query status of all channels >GetSta Response: 01 02 03 04 05 06 07 08 State O 12 12 12 12 12 12 12 12 Over N Out: out channel State: O-Open, S-Shut Vm: voltage Over: overload N-NO Y-Yes...
  • Page 16: Technical Specifications

    DL-PSU8 Installation Guide Technical Specifications Input/Output Connections Inputs Two (2) IEC 320 C13/C14 Male Input Voltage 100~240VAC 50~60Hz Outputs Eight (8) 2-Pin terminal block Output Voltage 5V, 12V, 18V, 24V or 48V; selectable. Maximum output power consumption of 5V:12W signal channel 12/18/24/48V:15W Control Ethernet...
  • Page 17 Thank you for your purchase. For Technical Support please call our toll free number at 800-530-8998 or email us at supportlibav@libav.com www.libav.com Digitalinx is a brand of:...

Table of Contents