Download Print this page

National Instruments NI VB-8012 Safety, Environmental, And Regulatory Information page 2

Advertisement

Safety Voltages
Connect only voltages that are within these limits.
DMM Isolation Voltages
Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock.
Channel-to-earth ground
Continuous...............................................................300 V, Measurement Category II
Withstand.................................................................3,000 V
Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level
electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.
Caution Do not connect the VirtualBench to signals or use for measurements within Measurement Categories III or IV.
DC Power Supply Isolation Voltages
+25 V and -25 V-to-earth ground continuous ........................60 VDC, Measurement Category I
Note Measurement Categories CAT I and CAT O (Other) are equivalent. The input circuits are not intended for direct connection to the MAINs
building installations of Categories CAT II, CAT III, or CAT IV.
Power Requirements
Caution The protection provided by the VB-8012 can be impaired if it is used in a manner not described in the user documentation.
Voltage input range ................................................................100 to 240 VAC, 50/60 Hz
Power consumption................................................................100 W maximum
Power input connector ...........................................................IEC C13 power connector
Power disconnect ...................................................................The AC power cable provides main power disconnect. Do not position the equipment so that it is
Preparing the Environment
Ensure that the environment you are using the NI VB-8012 in meets the following specifications.
Operating temperature ...........................................................0 to 40 °C
Cooling...................................................................................Forced air circulation (positive pressurization) through a fan. Fan speed automatically adjusts
Pollution Degree ....................................................................2
Maximum altitude..................................................................2,000 m
Indoor use only.
Note Refer to the NI VirtualBench VB-8012 Specifications on ni.com/manuals for complete specifications.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications.
These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational
electromagnetic environment.
This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a
peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and
prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation.
Furthermore, any modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local
regulatory rules.
Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories.
2 | ni.com | NI VB-8012 Safety, Environmental, and Regulatory Information
, verified by a 5 s dielectric withstand test
rms
difficult to disconnect the power cable. Depressing the front panel power button does not inhibit
the internal power supply.
according to operating conditions. Intake and exhaust locations are on rear of device. Ensure that
the intake and exhaust locations are not obstructed.

Advertisement

loading