Samsung AQT18P0GED/AND Owner's Instructions Manual

Split-type room air conditioner (cool and heat)

Advertisement

Split-type Room Air Conditioner (Cool and Heat)
Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción)
Climatiseur de type Séparé (Refroidissement et Chauffage)
E S F A DB98-20879A(2)
OWNER'S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D'UTILISATION
Indoor unit
AQT18P0GBD(S)
AQT18P0GED(S)
AQT24P6GBD(S)
AQT24P6GED(S)
Outdoor unit
UQT18P0GBD(S)
UQT18P0GED(S)
UQT24P6GBD(S)
UQT24P6GED(S)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AQT18P0GED/AND

  • Page 1 Split-type Room Air Conditioner (Cool and Heat) Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción) Climatiseur de type Séparé (Refroidissement et Chauffage) E S F A DB98-20879A(2) OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION Indoor unit Outdoor unit AQT18P0GBD(S) UQT18P0GBD(S) AQT18P0GED(S) UQT18P0GED(S) AQT24P6GBD(S)
  • Page 2: Safety Precautions

    URING OPERATION ISPOSING OF THE UNIT THERS Register your product at www.samsung.com/global/register If you don’t follow the safety precautions, you may get the risk of an electric shock, injury or death. The manufacturer or qualified service personnel must install this air conditioner.
  • Page 3: Table Of Contents

    Contents REPARING YOUR AIR CONDITIONER Safety Precautions ........View of the Unit .
  • Page 4: View Of The Unit

    View of the Unit The design and shape are subject to change according to the model. Indoor Unit Auto grille Air filter (under the grille) Timer indicator Sleep Timer indicator Fan speed setting Air Inlet Air flow blades (outlet) Operation indicator Set temperature &...
  • Page 5: Outdoor Unit

    Outdoor Unit Air Inlet(Rear) Air Outlet Connection Valve...
  • Page 6: Remote Control-Buttons And Display

    Remote Control - Buttons and Display Remote control transmission indicator Battery discharge indicator Fan speed Anion indicator Sleep mode On Timer setting On/Off button Mode selection button (AUTO, COOL, DRY, FAN, HEAT) Fan speed adjustment button Turbo button On Timer button Off Timer button Operating mode AUTO,...
  • Page 7: Getting Started

    etting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features.
  • Page 8: Inserting The Remote Control Batteries

    Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
  • Page 9: Selecting The Automatic Operating Mode

    Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the optimum temperature and the fan speed is selected automatically. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 10: Cooling Your Room

    Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 11: Heating Your Room

    Heating Your Room You must select the Heat mode if you wish to adjust the: Heating temperature Fan speed when heating If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 12: Changing The Room Temperature Quickly

    Changing the Room Temperature Quickly The Turbo cooling/heating function is used to cool or heat your room as quickly as possible. You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
  • Page 13: Removing Excess Humidity

    Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 14: Airing Your Room

    Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 15: Selecting Energy Saving Mode

    Selecting Energy Saving Mode If you wish to save energy when using your air conditioner, select the Energy saving mode with the Energy saving button. If necessary, press the (On/Off) button. Result: The operation indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 16: Generating Anion

    Generating Anion The air conditioner can generate anion with an ionizer in the indoor unit. Since it is an additional function, you can select it any mode, even when the air conditioner is turned off. Press the button. Result: The air conditioner generates anion. The indoor unit beeps.
  • Page 17: Adjusting The Air Flow Direction Vertically

    Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. Press the button one or more times as required.
  • Page 18: Setting The On Timer

    Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the the required time is displayed.
  • Page 19: Setting The Off Timer

    Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the the required time is displayed.
  • Page 20: Setting The Sleep Timer

    Setting the Sleep Timer The Sleep Timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of 6 hours. If you wish to switch the unit off at a specific time, refer to page 19.
  • Page 21: Operating Recommendations

    Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Heating performances The heat pump inside the air conditioner absorbs heat from outside air and brings it indoors. If the temperature of the outside air drops, the air conditioner will heat less.
  • Page 22: Temperature And Humidity Ranges

    Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... High temperatures Low temperatures High humidity levels Mode Outdoor Temperature Heating 0°C to 24°C approx. Cooling 21°C to 54°C approx.
  • Page 23: Solving Common Problems

    Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem The air conditioner does not operate at all The air conditioner does not operate with the remote control No beep is heard when you press (On/Off) on the remote control...
  • Page 24: Cleaning Your Air Conditioner

    Cleaning Your Air Conditioner Grille support Body groove Lower front grille Hook Cleaning Deodorizing and Bio Filters (Option) Deodorizing Filter Bio Filter For the best use of your air conditioner, you must clean it every two weeks regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you IMPORTANT have switched off the breaker used for the unit.
  • Page 25: Technical Specifications

    Technical Specifications Model Indoor unit AQT18P0GBD(S) AQT24P6GBD(S) AQT18P0GED(S) AQT24P6GED(S) Power Supply 220V~, 60Hz 220-240V~, 50Hz...