Smpte vitc/ltc code reader ltc generator led display (19 pages)
Summary of Contents for HORITA TR-100 Series
Page 1
HORITA TR-100 USER MANUAL MULTI FRAME RATE SMPTE TIME CODE READER WITH LED DISPLAY Doc. 073129-00 Rev. B (C) Copyright 2014 P.O. Box 3993, Mission Viejo, CA 92690 (949) 489-0240 www.horita.com...
Page 2
No part of this document may be copied or reproduced in any form or by any means without prior written consent of HORITA CO., P.O. Box 3993, Mission Viejo, CA 92690. HORITA CO. makes no warranties with respect to this documentation and disclaims any warranties of merchantability or fitness for a particular purpose.
TABLE OF CONTENTS SECTION PAGE GENERAL FEATURES SMPTE/EBU TIME CODE LTC – Longitudinal/Linear Time Code Drop Frame Time Code CONNECTING THE TR-100 Connecting Power Connecting LTC In and Out Connecting MIDI Out OPERATING THE TR-100 Controlling the Display Display Description MIDI Time Code Output Frame Rate Display MAINTENANCE...
The TR-100 provides both a MIDI time code output as well as a reshaped LTC output. The TR-100 comes standard as a small desktop unit, but can be installed in a standard 19" rack using the HORITA S100EK Rackmount Ear kit. It can also be attached to a wall or other piece of equipment using the HORITA S100SK Wallmount Swivel Bracket kit.
It is called longitudinal or linear time code because it was originally recorded along the length of a video tape by a stationary recording head as the video was being recorded as magnetic stripes on the rest of the tape by a spinning recording head.
NOTE: Make sure the plug is inserted all the way into the power connector or else damage to the power adapter may result. Do not use an adapter of more than 9 volts at 500 milliamperes or damage to the TR-100 may result. 4.2 Connecting LTC In and Out Figure 4-1 shows a basic hookup for the TR-100.
During display of the time code value, the top discrete LED for the colon between the seconds and frames digits “flashes” to indicate reading of time code as follows: FLASH RATE MEANING Indicates that an active LTC input to the TR-100 is not present. Fast Indicates LTC is being read at play speed and MIDI time code quarter frame messages are being output.
TR-100 with at least 9 volts (maximum of 14 volts) when the TR-100 is switched on. There are no internal adjustments in the TR-100. You may return your TR-100 to HORITA for service. Please contact HORITA first, either by phone or mail, before returning your unit.