2. Installation of Air and Flue Pipes ..................7 3. Oil Burner and Pipes ......................9 4. Electric installation......................10 Points to note before putting the machine into operation ............12 OPERATING INSTRUCTIONS OF THE HEATER ..............12 SERVICE..........................13 GUARANTEE ........................13 DISTURBANCES ......................... 14 ANTTI-TEOLLISUUS OY...
Page 5
Heater Type This booklet gives information on the installation and operation of A170 - A400 heaters. Information of the type of your heater is stamped on the name plate on the side of the machine.
In addition to this is required a tank for light-oil and a pipeline from the oil tank to the burner, which fulfils the valid regulations. - The noise emission by heater type in the heater room is: A170 86 dB A190...
- Weights of the heaters: Type Weight kg Type Weight kg A250 A170 380 A330 A190 465 A400 - The heater without the burner is lifted in place in accordance with the installation drawing or plan. Because the foundation has to be level and steady, there is no need to attach the heater to its bed.
2. Installation of Air and Flue Pipes - The air piping between the heater and the dryer is installed by using Antti air pipe parts (D630 mm). Note!: The airflow regulator is not installed in these pipes - it belongs to the suction piping of the heater.
Page 9
Antti-heaters - Lead the inlet air pipe from the suction opening of the fan to the outside air. The air pipe (L= 0.23 m) with the airflow regulator, is installed in the inlet pipe in a place where it is easy to use.
NOTE! Do not install over-sized nozzles or adjust the oil pressure setting so high that the maximum permissible oil amount for the burner will be exceeded ANTTI-TEOLLISUUS OY...
Antti-heaters 4. Electric installation All electrical installations and the installation and connection of the thermostats in the separate electric centre shall be left to an authorised electrician! Instructions for installation of the thermostats intended for the electrician: - The temperature regulator (LTM thermostat) is installed in the air pipe at maximum at 2.0 m distance from the heater in an opening which is made at the average height of pipe or above it.
Page 12
LTS -thermostat outlet end 2-nozzle probe (drying temperature) It is recommended that the drying air PTC probe is placed on the opposite side to the burner at about 0,5 m distance from the outlet end of the drying section ANTTI-TEOLLISUUS OY...
Antti-heaters Points to note before putting the machine into operation: - The burner mechanics and electricians have carried out the test run. - The oil tank is filled with clean light-oil. - There are no objects in the heater room that do not belong there.
GUARANTEE The guarantee period of Antti heaters is one (1) operating season. A five-year guarantee is granted to the fire surfaces of the heater. The guarantee covers defects in material and workmanship. As far as the electric motors are concerned, separate guarantee terms issued by the importer apply.
Antti-heaters DISTURBANCES Possible faults in the oil burner Signs Possible cause Measures to be taken Engine starts Photocell does not see light Check that photocell is clean and sees the light of the flame Burner pre-ventilates Photocell faulty Check using a new photocell...
Page 16
Vacuum in heater room Burning switching off heater room air openings missing Vacuum in heater room Suction Intake air pipe of heater has to air intake of heater fan from be led to outside inside the heater room. ANTTI-TEOLLISUUS OY...
Page 17
Antti-heaters Disturbance of burner function Nozzle outputs do not Replace nozzles correspond to heater output Nozzles clogged Burner pulsates Overpressure plate rattles Impeller of burner fan dusty Clean impeller False adjustment of burning head Adjust burning head according to Burner Manual...
Page 18
90,0 10 gal 80° 28.39 l 60° In case of failure reset the burner by pushing the button with light at the side of the burner 1 kg light heating oil = 1,18 litres light heating oil ANTTI-TEOLLISUUS OY...
Page 20
Fax +358 2 774 4777 declares that the following machinery which is placed on the market A170, A190, A330 and A400 heater conform with the provisions of the Machine Directive 98/37/EY with its amendments and to national decrees (VNp 1314/94) through which they have been brought into force. The machine also conforms to the provisions of the following EC directives and the corresponding national decrees.
Need help?
Do you have a question about the A170 and is the answer not in the manual?
Questions and answers