Installation and
Operating Instructions
ANTTI DRYER HEATER
(Gas-fuelled heater, direct driven)
VACBOOST M09 A1500
408102 (en)
06-2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VACBOOST M09 A1500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ANTTI VACBOOST M09 A1500

  • Page 1 Installation and Operating Instructions ANTTI DRYER HEATER (Gas-fuelled heater, direct driven) VACBOOST M09 A1500 408102 (en) ANTTI-TEOLLISUUS OY Koskentie 89 FI-25340 Kanunki, Salo Tel. +358 2 774 4700 Fax +358 2 774 4777 E-mail: antti@antti-teollisuus.fi 06-2010 www.antti-teollisuus.fi...
  • Page 2: Table Of Contents

    CONTENTS Dryer heater type ..............................3 PRESENTATION OF THE MACHINE ........................4 Suitable gases: ............................... 5 PURSUED CONFIGURATION ..........................6 INSTALLATION ..............................8 Safety instructions and regulations......................... 8 Selecting the installation location ........................... 8 Components to be installed in front of the gas burner .................... 8 Gas reservoir/connection............................
  • Page 3: Dryer Heater Type

    Dryer heater type This book deals with the Antti A1500 range of gas fuelled, direct driven dryer heaters. Channel burners are avail- able for two different gases; liquid gas and natural gas. The basic components of the two burners are similar. Refer to the nameplate affixed to the side of the machine for detailed information about the type of your heater.
  • Page 4: Presentation Of The Machine

    The electric installations of the grain dryer's control centre must be carried out by an electrician. In addition is required a supply/reservoir of gas, and a pipeline from it to the burner, installed in accordance with the regulations. Antti-Teollisuus Oy 408102 06-2010...
  • Page 5: Suitable Gases

    17.3 A70240 DR HEATER A1500 FURNACE ASSEMBLY A70240 128.1 A70251 DR HEATER A1500 BASE A70251 A70597 DR HEATER A1500 NAMEPL ANTTI A70597 A71290 DR HEATER A1500 SUCTION CONE A71290 66.8 800074 GAS BURNER A1500 OILON GP 90H A70238 RAIN COVER BURNER ASSEMBLED A-500 - A-1500...
  • Page 6: Pursued Configuration

    - If the heater is protected against rain, it can be installed at a distance of at least three (3) metres from the grain dryer and other buildings. The length of the air duct between the glowing parts of the heater and the air channel end must be 6 metres. Antti-Teollisuus Oy 408102 06-2010...
  • Page 7 The above-mentioned distances also apply if an existing dryer is converted to a vacuum dryer. Primarily, the same regulations apply to insulated and sheet-metal-clad StandAlone dryers that are installed out of doors than to silo element dryers that are constructed of steel. Antti-Teollisuus Oy 408102 06-2010...
  • Page 8: Installation

    THE BURNER OF THE HEATER MUST ABSOLUTELY BE PROTECTED AGAINST THE RAIN. IF THE BURNER IS NOT PROTECTED, ANTTI-TEOLLISUUS OY WILL NOT ASSUME ANY LIABILITY FOR THE CONSEQUENCES. Inlet air for the dryer heater must not be routed from inside the heater room, but the room must be equipped with openable doors for this purpose.
  • Page 9: Lifting The Dryer Heater In Place

    Natural gas 150.0 m If you know the energy content of the gas, you will be able to calculate exactly the maximum allowed gas volume. NOTE! The maximum allowed output of the heater must not be exceeded! Antti-Teollisuus Oy 408102 06-2010...
  • Page 10: Electric Installation

    - The purpose of the pressure difference sensor is to monitor that the air flows through the heater and does not take any other route of lower resistance. Therefore, it must not be installed anywhere else than in the inlet air pipe after the heater. Antti-Teollisuus Oy 408102 06-2010...
  • Page 11 If you apply drying temperatures higher than normally, the cut-off temperature will also be higher than normally. Install the sensor inside the pipe in the same manner as the drying air sensor, mentioned above in this manual. Antti-Teollisuus Oy 408102 06-2010...
  • Page 12 Also ensure, that there is no direct line of vision from the sensors to the rear part of the combustion chamber. The heat radiation from the chamber transmits wrong measurement results to the thermostats. Antti-Teollisuus Oy 408102 06-2010...
  • Page 13: Operating Instructions For The Dryer Heater

    - The heater fan cannot be switched off even via its own operating switch before the heater has cooled down below the "fan” temperature of the LTM thermostat (nor shall the heater blower be switched off from the main switch until the heater has cooled down). Antti-Teollisuus Oy 408102 06-2010...
  • Page 14: Servicing

    GUARANTEE The guarantee period for the Antti-heaters runs for one (1) operating season. A five-year guarantee is granted to the fire surfaces of the heater. The guarantee covers defects in material and workmanship. Separate guarantee terms issued by the manufacturer apply to the oil burner.
  • Page 15: Possible Malfunctions In The Gas Burner

    Check the setting, repair as required abruptly during pre-ventilation or after that sure switch (symbol P) The impulse hose(s) for the air differential Clean the hose(s) pressure switch dirty Faulty air differential pressure switch Replace Soiled blower Clean Antti-Teollisuus Oy 408102 06-2010...
  • Page 16 – or when the burner steps up to the 2nd stage – the operation stops (gas pressure switch, min.), and a restart Clogged filter Clean the filter follows. Setting of the gas pressure switch (min.) Adjust faulty Antti-Teollisuus Oy 408102 06-2010...
  • Page 17 - faulty adjustment ring position Adjust 9. Malfunction of leak tester Burner does not start. See point “Leak tester” in the burner manual Red signal light is illuminated Leak tester is faulty Replace Gas valve is leaking Replace Antti-Teollisuus Oy 408102 06-2010...
  • Page 18: Eu Declaration Of Conformity

    Koskentie 89 FI-25340 KANUNKI Tel.: +358 (0)2 7744700 Fax +358 (0)2 7744777 declares that ANTTI VACBOOST M09 A1500 - DRYER HEATER (Gas-fuelled heater, direct driven) conforms with the provisions of the following directives: Machine Directive 2006/42/EC Low Voltage Directive 2006/95/EC Electro-Magnetic Compatibility Directive (EMC) 2004/108/EC Kuusjoki 11.05.2009...