WB-OVRC-UPS-625-8
WB-OVRC-UPS-850-8
QUICK START GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for watt box WB-OVRC-UPS-625-8

  • Page 1 ™ WB-OVRC-UPS-625-8 WB-OVRC-UPS-850-8 QUICK START GUIDE...
  • Page 2: Box Contents

    BOX CONTENTS • WattBox UPS • IEC power cord • 4 × rubber feet FRONT PANEL A. AC Power Switch. • A short press of less than 1 second turns on the bat- tery backup outlets (item D). • When battery backup is on and the alarm is sound- ing, a short press (less than 1 second) mutes the alarm sound until the next AC power loss.
  • Page 3: Rear Panel

    REAR PANEL G. Feet. H. Mounting Keyholes for vertical and horizontal mounting. SIDE PANEL Circuit Breaker Reset Button: Press this button to restart the WattBox after an overcurrent condition causes it to shut down to protect your gear. Power Inlet: Detachable power cord outlet for 3 prong IEC power cord. K.
  • Page 4: Installation

    INSTALLATION The 625VA / 850VA UPS is designed to sit on a desk, floor, or other flat surface (like a shelf). It can also be mounted (vertically or horizontally) on a flat surface using the slots on the back. Drill two holes, 16cm apart and aligned on a stud in the wall.
  • Page 5 CLAIMING THE WATTBOX ON OVRC When connected to an IP-enabled WattBox power conditioner, this unit adds additional features to the power conditioner. For example, the power conditioner can show battery health and allow for load shedding (when in battery mode). If you are not familiar with OvrC, visit OvrC.com.
  • Page 6 UPS Power on When UPS is powered on, it will enter this mode for 4 seconds. AC Mode LCD information will be displayed in the following order when LCD is touched. Output voltage Input voltage Load level as a percent Battery capacity as a percent Overload mode Can occur under AC power and battery power.
  • Page 7 Fault Code Battery backup outlets This occurs when the UPS enters Disconnect short-circuited loads and have short circuited battery mode and the output voltage is restart the UPS again. less than 30V. Overdraw on surge-only This occurs when the UPS is in AC Disconnect all output loads and restart outlets mode and the load is greater than 120%...
  • Page 8: Led Indicators

    LED INDICATORS Surge Green The unit has power and all outlets are surge protected. Protected There is no AC power supplied to the unit, or the MOVs have been consumed by a surge event. Site Fault Incoming AC outlet is grounded. Incoming AC outlet is not grounded and requires inspection by an electrician.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS / CONSIGNES DE SÉCURITÉ IMPORTANTES Read and observe the following safety points at all times. Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries.
  • Page 10 la pile connectée à la terre peut provoquer un choc électrique. La probabilité d’un tel choc peut être réduite si ces terres sont éliminées lors de l’installation et de la maintenance. NOTICE / AVIS For indoor use only. Internal components are not sealed from the environment. The device can only be used in a fixed location such as a telecommunication centre, or a dedicated computer room.
  • Page 11 WARNING – Power Sources, Grounding, Polarization / AVERTISSEMENT – Sources d’alimentation électrique, mise à la terre, polarisation The UPS must be connected to a grounded electrical outlet. This plug is designed to be inserted into a NEMA 5-15 (three-prong grounded) outlet only. Do not force the plug into an outlet that is not designed to accept it. Never dismantle the plug or to alter the power cord, and do not attempt to defeat the grounding feature by using a 3-to-2 prong adapter.
  • Page 12 Ne placez pas le cordon d’ a limentation près de zones de haute circulation piétonnière (par exemple, des couloirs). Ne créez pas de risque de chute avec le cordon d’ a limentation. Si l’ e nveloppe de protection du cordon se déchire, comme le câblage interne ou le blindage est exposé, débranchez-le de la source d’...
  • Page 13 FCC WARNING / AVERTISSEMENT DE LA FCC WARNING!! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. AVERTISSEMENT !! Toute modification sur cet appareil sans l’ a pprobation par la partie responsable pour la conformité pourrait annuler l’...
  • Page 14 Notice: (1) An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord by used. (2) Use only shielded cables to connect I/O devices to this equipment.
  • Page 15 SNAPAV SURGE PROTECTOR CONNECTED EQUIPMENT PROTECTION POLICY CAUTION: Audio/video, computer and/or telephone system installations can be very complex systems of interconnected components. A single protector may not be able to completely protect complex installations. In those cases, employ a systemic approach using multiple protectors.
  • Page 16: Year Limited Warranty

    pack it in a shipping carton/box with enough packing material to protect it during transit. The RA number must also be clearly marked on the outside of the carton. Ship the unit to SnapAV. Please note that you are responsible for any and all charges related to shipping the unit to SnapAV.