Uni-P EpiFresh 550 AIR MOVERS
INSTRUCTIONS
SET UP
1. Place the Unip EpiFresh 550 so that it is in the upright, vertical position.
2. Plua the machine into a standard 115 volt outlet. Note: Each unit needs 3 amps to operate.
3. Power the unit on and adjust the speed by turning the variable speed control. The maximum
speed is 550 CFM and the minimum speed is 270 CFM.
4. The Unip EpiFresh 550 can be operated in the vertical or horizontal postion, depending on
the exact situation. At this point, adjust the machine to the optimal position.

THE CONTROL PANEL

Variable Speed Control
The Variable Speed Control is used to adjust the power of the machine. Turn the knob in a
clockwise direction, to increase the speed from minimum to maximum.The minimum speed
setting is located immediately under the OFF button. You can switch to minimum speed by
turning the knob counterclockwise.
Auxillary Outlet
If more air filtation is necessary for a space, you can "daisy chain" or link up to 3 Unip EpiFresh
550's to the same outlet. There is a maximum amperage of 12 when the units are turned off, a
maxium of 9 amps when the units are turned on. Other equipment can be plugged into the same
outlet as the EpiFresh as long as it doesn't go above the max amperage
Circuit Breaker Switch
The Circuit Breaker Switch protects the unit if there are more than 12 amps of electricity
passing the circuit. Iif this occurs, the switch will cut off the power to the unit.
Tel: 888-990-7469
Installation, Operation & Service Instructions
3
Uni-P EpiFresh 550 AIR MOVERS
CHANGE THE FILTERS
1. Loosen the 4 locks that hold the fiter board in place
2. Slide out the fiter panel board.
3.Remove the used filters and replace with new fiters.
WARNING
Always wear approved protective gear when changing the filters.
Filters should be changed after each remediation job.
If the indicator light is on, always change the HEPA filter.
APPLICATIONS
Water Damage
In this application, the Unip EpiFresh 550 should be placed in the center of the affected area. The
air scrubber will draw in the air, filter it, then blow out the newly cleaned air. To begin the process,
simply turn on the scrubber and it will start cleaning the air. Keep in mind that if you are working in a
large area or one divided by walls, you may need several air scrubbers to effectively clean the air.
Odor Control
The Unip EpiFresh 550, when used with the optional activated carbon filer (P/N:), is excellent at
odor control, as well. Simply place the carbon filter in the pre-filter slot and it will capture a wide
variety of odor-causing gas molecules, such as volatile organic compounds (VOC's), smoke.soot,
and paint fumes.
Other Uses
The Unip EpiFresh 550 is also useful in many other applications including mold remediation, fire
damage, dust control, and sewage remediation.
WARNING
Breathing Hazard
When using the Unip EpiFresh 550 in a containment area, always turn off power to open combustion
appliances, such as firelaces, furnaces, water heaters, and HVAC systems, to avoid the risk of
backdrafting carbon monoxide fumes.
If the Filter Change Light illuminates during the remediation process, immediately change the
HEPA filter
Tipping Hazard
Use caution when stacking units,
Do not stack more than 2 units on top of each other
Falling equipment could cause bodily harm.
4
Installation, Operation & Service Instructions
Tel: 888-990-7469

Advertisement

loading