GRIDDLE
FOR YOUR SAFETY
DANGER
If you smell gas:
Shut off gas to the appliance
Extinguish any open flame
Open Lid
If odor continues, keep away from the
appliance and immediately call your gas
supplier or fire department
Never operate this appliance unattended
Never operate this appliance within 25 ft (7.5
m) to any flammable liquid
If a fire should occur, keep away from the
appliance and immediately call your fire
department. Do not attempt to extinguish
any oil or a grease fire with water.
Failure to follow these instructions could result
in fire or explosion which could cause property
damage, personal injury, or death.
WARNING
Do not store or use gasoline, or other flammable
vapors or liquids in the vicinity of this or any
other appliance.
PN: 205514
08-03-2019
INSTALLATION,
OPERATION and
USER'S MANUAL
WARNING
This instruction manual contains important
information necessary for the proper assembly
and safe use of the appliance.
Read all safety,
maintenance instructions thoroughly before
installing or servicing this equipment.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage.
The installation of this appliance must conform
with state or other codes, or, in the absence of
such codes, with either the National Fuel Gas
Code, ANSI Z223.1 / NFPA 54, or the Standard for
Recreational Vehicles, ANSI A/NFPA 1192, and
CSA Z240 RV Series, Recreational Vehicle Code,
as applicable.
IMPORTANT
INSTALLER
/
OWNER:
INSTRUCTIONS ARE TO BE LEFT WITH THE END USER
OF THIS APPLIANCE. RETAIN THESE INSTRUCTIONS AND
WARRANTY INFORMATION FOR FUTURE REFERENCE.
ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE
DIRECTED TO THE COMPANY LISTED ON THE WARRANTY
OR RATING PLATE WHICH CAME WITH YOUR APPLIANCE.
MODELS:
SOP-1002A
SOP-1003A
OUTDOOR USE ONLY
FOR RECREATIONAL
VEHICLE USE
CERTIFIED UNDER:
ANSI Z21.89-2017 / CSA 1.18-2017
installation, operating, and
THESE
WARNINGS AND

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Suburban Elite Series and is the answer not in the manual?

Questions and answers

Kayla
May 2, 2025

How do I light this thing

User image 6815562028066
1 comments:
Mr. Anderson
May 17, 2025

To light the Airxcel Series:

1. Make sure the control knob is in the OFF position.
2. Push the control knob in and turn it counter-clockwise to the “Light” position.
3. If ignition does not occur in 5 seconds, turn the control knob to OFF, wait 5 minutes, and try again.

For match lighting:

1. Ensure the control knob is OFF.
2. Remove the griddle top.
3. Light an 11” long match and place it near the ignition electrode on the right or left side of the burner.
4. Push the control knob in and turn it counter-clockwise to HIGH.
5. Confirm the burner lights and stays lit.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Airxcel Suburban Elite Series

  • Page 1 INSTALLATION, OPERATION and USER’S MANUAL MODELS: SOP-1002A SOP-1003A GRIDDLE OUTDOOR USE ONLY FOR RECREATIONAL VEHICLE USE CERTIFIED UNDER: ANSI Z21.89-2017 / CSA 1.18-2017 FOR YOUR SAFETY WARNING This instruction manual contains important DANGER information necessary for the proper assembly If you smell gas: and safe use of the appliance.
  • Page 2: Table Of Contents

    WARNING RATINGS LABEL REPLACEMENT PARTS It is the consumer’s responsibility to see that the WARRANTY Suburban Elite Series griddle is properly assembled, installed and maintained. Failure to follow the instructions in this manual could result in bodily IMPORTANT SAFETY injury and/or property damage.
  • Page 3: Package Contents

    WARNING INSTALLATION SAFETY PRECAUTIONS • Suburban Griddle installation must conform with • This appliance shall be used outdoors only, and local codes, or in the absence of local codes, with shall not be used in a building, garage, or any either the National Fuel Gas Code, ANSI Z223.1/ other enclosed area.
  • Page 4: Installation Instructions

    Standard for The Suburban Elite Series Griddle must be installed Pigtails and Flexible Hose Connectors for LP Gas, on the opposite side from the fuel distribution/ ANSI/UL 569, and shall be of a length no longer dispensing system of the recreational vehicle.
  • Page 5: Sop1003A

    4. Install grease tray into front control panel as shown in the illustration on page 3. 5. Find a large, clean area in which to assemble your Suburban Elite Series Griddle. NOTE: Make sure all the plastic protection and packaging is removed before assembling.
  • Page 6: Operating Instructions

    TURNING OFF THE GRIDDLE OPERATING Turn the CONTROL KNOB to the OFF position. INSTRUCTIONS IGNITION ELECTRODE POSITION ALL MODELS The ignition needle should be .175” from the top of the burner to create the proper spark, as shown in the LIGHTING THE GRIDDLE illustration below.
  • Page 7: Sop1002A

    Baked-on grease deposits may require the use of an SAFETY GUIDELINES abrasive plastic cleaning pad. Use only in direction of • When the Suburban Elite Series Griddle is not in use, brushed finish to avoid damage. Do not use abrasive ensure the control knob is in the OFF position. pad on areas with graphics.
  • Page 8: Food Safety

    STORING YOUR GRIDDLE CLEANING THE BURNER ASSEMBLY Follow these instructions to clean the burner. DANGER 1. Turn gas OFF at the control knob. Do not put griddle in storage or travel mode 2. Ensure all components have cooled immediately after use. Allow griddle to cool to touch 3.
  • Page 9: Troubleshooting Guide

    Clean injection and gas hose roaring noise Burner could be damaged Call Suburban Customer Service Contact Suburban - A Division of Airxcel Customer Service Department at 423.775.2131 EXT: 7101 for help troubleshooting, assembly questions, operation problems, and replacement parts (if required).
  • Page 10: Product Specifications

    PRODUCT SPECIFICATIONS MODELS: SOP-1002A and SOP-1003A SOP-1002A - PERMANENT INSTALLATION SOP-1003A - PORTABLE / TABLETOP BURNER INPUT RATE 11,000 BTU/h BURNER INPUT RATE 11,000 BTU/h INLET GAS PRESSURE MAX: 13 inches W.C. (Water Column) INLET GAS PRESSURE MAX: 13 inches W.C. (Water Column) UNIT WEIGHT 18 lbs.
  • Page 11: Ratings Label

    The unit ratings label can be located inside the burner box. To view the ratings label, remove the Griddle Plate. MODEL SOP-1002A MODEL SOP-1003A PERMANENT INSTALLATION RATINGS LABEL PORTABLE / TABLETOP RATINGS LABEL AIRXCEL, INC. - SUBURBAN DIVISION DAYTON, TENNESSEE 37321 AIRXCEL, INC. - SUBURBAN DIVISION DAYTON, TENNESSEE 37321 Model Number/Numéro de modèle: SOP1002A FOR OUTDOOR USE ONLY | Model Number/Numéro de modèle: SOP1003A...
  • Page 12: Warranty

    PROOF OF PURCHASE. Suburban - A 3. Damage or repairs required as a consequence of faulty or Division of Airxcel; hereafter referred to as Suburban, does not incorrect assembly or application not in conformance with use warranty registration therefore, you are required to furnish Suburban instructions.