JVC AV-48P575 Series Service Manual page 49

Rear projection television
Table of Contents

Advertisement

4.7.4.3
DEFLECTION ADJUSTMENT
Measuring
Item
instrument
V. POSITION /
Signal
SIZE /
generator
LINEARITY
adjustment
Remote
control unit
C
C
AV-48P575
C
H. POSITION
Signal
adjustment
generator
Remote
control unit
D
H. SIZE
Signal
adjustment
generator
Remote
control unit
1-48 (No.YA091)
Test point
Adjustment part
[1.PICTURE/SOUND]
D01 : V. SIZE
D05 : V. LINE
D06 : V. CENT
F62 : Without
convergence operation
no-signal area
no-signal area
AV-56P575
AV-56P585
35mm
50mm
[1.PICTURE/SOUND]
D14 : H. CENTER
F62 : Without
convergence operation
E
[1.PICTURE/SOUND]
D03 : H. SIZE
F62 : Without
convergence operation
Screen size
(92%)
Picture size
100%
• To memorize every time after finish adjustment on each
mode.
(1) Receive NTSC circle pattern signal.
(2) Select FULL mode with [ASPECT] key.
(3) Select 1. PICTURE/SOUND from SERVICE MENU.
(4) Select < F62 > (Without convergence operation).
(5) Change the data 0 to 1, then it makes picture without
convergence operation.
(6) Select < D01 > (V. SIZE), < D05 > (V. LINE) and
A
< D06 > (V. CENT).
(7) Adjust < D01 >, < D05 > and < D06 > to make A = B
(precision ±2mm), and adjust to make C same value
as table.
(8) Press [MUTING] key to memorize the set value.
(9) After adjustment, select < F62 > and change the
B
data 1 to 0.
(10) Press [MUTING] key to memorize the set value.
NOTE :
Do not adjust < D04 > (V. SCORE), if it is different
vertical position after adjust vertical linearity, to adjust
vertical position.
(1) Receive NTSC circle pattern signal.
(2) Select FULL mode with [ASPECT] key.
(3) Select 1. PICTURE/SOUND from SERVICE MENU.
(4) Select < F62 > (Without convergence operation).
(5) Change the data 0 to 1, then it makes picture without
convergence operation.
(6) Select < D14 > (H. CENTER).
(7) Adjust < D14 > to make D = E as shown figure.
(8) Press [MUTING] key to memorize the set value.
(9) After adjustment, select < F62 > and change the
data 1 to 0.
(10) Press [MUTING] key to memorize the set value.
(1) Receive NTSC crosshatch signal.
(2) Select FULL mode with [ASPECT] key.
(3) Select 1. PICTURE/SOUND from SERVICE MENU.
(4) Select < F62 > (Without convergence operation).
(5) Change the data 0 to 1, then it makes picture without
convergence operation.
(6) Select < D03 > (H. SIZE).
(7) Adjust < D03 > to make sure that the vertical screen
size of the picture size is 92%.
(8) Press [MUTING] key to memorize the set value.
(9) After adjustment, select < F62 > and change the
data 1 to 0.
(10) Press [MUTING] key to memorize the set value.
Description

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents