Symptom
Vacuum will not
operate.
Dust comes from
motor cover.
Reduced efficiency
and motor/speed
vibration.

TROUBLESHOOTING

Possible Causes
1) No power supply.
2) Faulty power cord.
3) Container full of liquid.
1) The dust filter is missing or
damaged.
1) There is a blockage in the
nozzle, the hose, or the
container inlet, or the dust
filter is blocked by fine dust.
Corrective Action
1) Check power supply – cord, breakers,
fuses.
2) Check the power cord and repair it or
replace it if necessary.
3) Empty container.
1) Attach or replace dust filter.
1) Check the nozzle, the hose, and the
container inlet for blockage. Take off
the dust filter, and wash and clean it.
Reuse it when it is dry.
It is recommended to use a new dust
filter.
41