  • Page 1 Operator's Manual Series 5016 Model 5016A Model 5016B Model 5016C Model 5016D MAN-5016 Rev A 2015 West Chestnut Street Alhambra, California 91803 (626) 293-3400 Fax: (626) 293-3428 www.emcore.com...
  • Page 2 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Disclaimer Every attempt has been made to make this material complete, accurate, and up-to-date. Users are cautioned, however, that Ortel reserves the right to make changes without notice and shall not be responsible for any damages, including consequential, caused by reliance on the material presented, including, but not limited to, typographical, arithmetical, or listing errors.
  • Page 3 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 WARNINGS, CAUTIONS, AND GENERAL NOTES Safety Considerations When installing or using this product, observe all safety precautions during handling and operation. Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of this product.
  • Page 4 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Service Do not attempt to modify or service any part of the system other than in accordance with procedures outlined in this Operator's Manual. If the system does not meet its warranted specifications, or if a problem is encountered that requires service, return the apparently faulty plug-in or assembly to Ortel for evaluation in accordance with Ortel's warranty policy.
  • Page 5 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 discrepancy. The device shall then be forwarded to Ortel, transportation prepaid. Devices returned freight collect or without authorization may not be accepted. b. Prior to repair, Ortel Sales will advise the customer of Ortel test results and will advise the customer of any charges for repair (usually for customer caused problems or out-of- warranty conditions).
  • Page 6 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 This fiberoptic laser transmitter contains a class IIIb laser product as defined by the U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration. This laser product complies with 21 CFR, Chapter I, Subchapter J of the DHEW standards under the Radiation Control for Health and Safety Act of 1968.
  • Page 7: Table Of Contents

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Table of Contents Chapter 1 General Information ....................8 Description........................8 Specification ........................8 Identification and Model Numbers.................. 10 Options ........................... 11 Chapter 2 Safety Precautions ....................... 12 ESD Sensitive......................... 12 Power Supply .........................
  • Page 8: Chapter 1 General Information

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Chapter 1 - General Information DESCRIPTION This manual describes the following fiberoptic transceivers model numbers: 5016A/B/C/D These fiberoptic products are designed to carry RF and microwave signals using singlemode optical fiber. They contain InGaAsP high-speed semiconductor lasers and photodiodes in a patented high-speed package.
  • Page 9 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 PRODUCT SPECIFICATION RF Parameters Frequency Range 5016A 0.1 to 4 GHz 5016B 0.1 to 10 GHz 5016C 1.0 to 15 GHz 5016D 1.0 to 18 GHz Insertion Loss Laser -26 dB...
  • Page 10: Identification And Model Numbers

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Maximum Ratings Input Power +20 dBm/60 sec Operating Temperature -20 to 65ºC Storage Temperature -40 to 85ºC Mechanical Dimensions Height 2.37 in Width 6.0 in Depth 6.0 in SMA (F)
  • Page 11: Options

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 1.3.1 OPTIONS Changes to the PST can; be accommodated by requesting non-standard options to meet specific performance requirements. Such options are designated by an alpha-numeric suffix, -XNN where X is alpha, and NN is numeric. Such custom options must be agreed upon in...
  • Page 12: Chapter 2 Safety Precautions

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Chapter 2 - Safety Precautions ESD SENSITIVE Semiconductor lasers and photodiodes are static sensitive devices, and products containing them should be treated accordingly. Static electricity can be conducted to the laser chip from the center pin of the RF input SMA connector, and through the DC connector pins.
  • Page 13: Chapter 3 Operation

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Chapter 3 - Operation THEORY OF OPERATION The Model 5016 series fiberoptic delay line uses an Ortel high-speed laser module to generate an intensity modulated optical signal at 1300 nm wavelength. The 5016 A/B/C/D uses a high performance distributed feedback (DFB) laser with a built-in optical isolator.
  • Page 14: Alarm Functions

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 3.1.3 ALARM FUNCTIONS The alarm is designed to interface with user-supplied circuits. The alarm is an open collector output capable of sinking 20 mA when ON and withstanding 15 Vdc when OFF.
  • Page 15: Temperature Stabilization

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 3.2.2 TEMPERATURE STABILIZATION The temperature control circuit senses the thermistor resistance in the laser module and compares it against a variable reference, which is preset at the factory. The error voltage drives an integrator, which supplies current to the T/E cooler (TEC).
  • Page 16: Chapter 4 Installation And Setup Procedures

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Chapter 4 - Installation and Setup Procedures UNPACKING AND VISUAL INSPECTION The product described herein was inspected before shipment and found to be free of mechanical and electrical defects. Observe ESD precautions while handling the delay line. Unpack and examine the product for any damage due to shipping.
  • Page 17: Rf Connection

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 4.3.1.2 RF CONNECTION Apply RF power only after DC power has been applied. Connect the RF signal source to the SMA input connector. Absolute maximum signal level shall not exceed 100 mW.
  • Page 18: Chapter 5 Performance Verification Procedures

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Chapter 5 - PE R F OR MANCE VE R IF ICAT ION PR OCE DUR E S Broadband Amplitude Response and VSWR Test Set-Up: See Figure 1. Amplitude and VSWR can be measured with a scalar network analyzer and a sweeper.
  • Page 19: Noise Figure Measurement

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 13. Activate the Copy menu and copy all on the plotter. Noise Figure Measurement Spectrum Analyzer HP 8350B Signal Generator Delay G > 30 dB Line F < 7 dB Figure 2 - Test Set-up: Signal to Noise 1.
  • Page 20 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 3. Set up the spectrum analyzer as follows: a. Center frequency frequency under test b. Span 50 MHz c. ATTEN 0 dB d. Scale 10 dB/div e. RES BW 1 MHz f.
  • Page 21: Linearity Test - Two Carrier Test

    Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 Linearity Test - Two Carrier Test HP 8350B Plotter Signal Generator Spectrum Analyzer HP 8350B Signal Generator Combiner Delay Line Figure 3 - Test Set-up: Two Tone Test 1. Connect the outputs of the two signal generators to the inputs of the combiner and connect the combiner output to the spectrum analyzer input.
  • Page 22 Ortel, A Division of Emcore MAN-5016 Rev A Series 5016 4. Set the center frequency to 9.025 GHz and the SPAN at 100 MHz. Leave the RES BW and the VID BW on AUTO. Set the ATTEN to 10 dB. Set the reference level and position so that the carriers are at the top line on the display.